- -

Impact accelerations during a prolonged run using a microwavable self-customised foot orthosis

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Impact accelerations during a prolonged run using a microwavable self-customised foot orthosis

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author JIménez-Pérez, Irene es_ES
dc.contributor.author Priego-Quesada, Jose Ignacio es_ES
dc.contributor.author Camacho-García, Andrés es_ES
dc.contributor.author Cibrian Ortiz De Anda, Rosa María es_ES
dc.contributor.author Pérez-Soriano, Pedro es_ES
dc.date.accessioned 2024-01-11T19:03:25Z
dc.date.available 2024-01-11T19:03:25Z
dc.date.issued 2021-05 es_ES
dc.identifier.issn 1476-3141 es_ES
dc.identifier.uri http://hdl.handle.net/10251/201846
dc.description.abstract [EN] The use of custom-made foot orthoses has been associated with numerous benefits, such as decreased impact accelerations. However, it is not known whether this effect could be due to better customisation. The present study analysed the effects of the first generation of a microwavable prefabricated self-customised foot orthosis vs. a prefabricated standard one on impact accelerations throughout a prolonged run. Thirty runners performed two tests of 30-min running on a treadmill, each one with an orthosis condition. Impact acceleration variables of tibia and head were recorded every 5 min. Microwavable self-customised foot orthosis increased the following variables in the first instants compared to the prefabricated standard one: tibial peak (min1: 6.5 (1.8) vs. 6.0 (1.7) g, P = .009, min5: 6.6 (1.7) vs. 6.2 (1.7) g, P = .035), tibial magnitude (min1: 8.3 (2.6) vs. 7.7 (2.4) g, P = .030, min5: 8.5 (2.6) vs. 7.9 (2.5) g, P = .026) and shock attenuation (min1: 61.4 (16.8) vs. 56.3 (16.3)%, P = .014, min5: 62.0 (15.5) vs. 57.2 (15.3)%, P = .040), and tibial rate throughout the entire run (504.3 (229.7) vs. 422.7 (212.9) g/s, P = .006). However, it was more stable throughout 30-min running (P < .05). These results show that the shape customisation entailed by the thermoformable material does not provide impact acceleration improvements. es_ES
dc.description.sponsorship This work was supported by the Centre for Industrial Technological Development (CDTI) [Project SPORT@FUTURE (IDI 20141290-IDI 20141296)], and the work of IJP was supported by the Ministry of Science, Innovation and Universities of the Spanish Government [grant number FPU 14/05626]. es_ES
dc.language Inglés es_ES
dc.publisher Taylor & Francis es_ES
dc.relation.ispartof Sports Biomechanics es_ES
dc.rights Reconocimiento - No comercial (by-nc) es_ES
dc.subject Insoles es_ES
dc.subject Thermoformed materials es_ES
dc.subject Running es_ES
dc.subject Biomechanics es_ES
dc.subject Shock es_ES
dc.subject.classification TEORÍA DE LA SEÑAL Y COMUNICACIONES es_ES
dc.title Impact accelerations during a prolonged run using a microwavable self-customised foot orthosis es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1080/14763141.2021.1902553 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MECD//FPU14%2F05626/ES/FPU14%2F05626/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//IDI-20141290/ES/INVESTIGACIÓN DE NUEVAS SOLUCIONES TEXTILES Y DE CALZADO DEPORTIVAS QUE MEJOREN LA SEGURIDAD, LA PROTECCIÓN, EL CONFORT, EL RENDIMIENTO Y EL BIENESTAR DEL DEPORTISTA DEL FUTURO: SPORT@FUTURE (1%2F7)/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//IDI-20141296/ES/INVESTIGACIÓN DE NUEVAS SOLUCIONES TEXTILES Y DE CALZADO DEPORTIVAS QUE MEJOREN LA SEGURIDAD, LA PROTECCIÓN, EL CONFORT, EL RENDIMIENTO Y EL BIENESTAR DEL DEPORTISTA DEL FUTURO: SPORT@FUTURE (7%2F7)/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Politécnica Superior de Alcoy - Escola Politècnica Superior d'Alcoi es_ES
dc.description.bibliographicCitation Jiménez-Pérez, I.; Priego-Quesada, JI.; Camacho-García, A.; Cibrian Ortiz De Anda, RM.; Pérez-Soriano, P. (2021). Impact accelerations during a prolonged run using a microwavable self-customised foot orthosis. Sports Biomechanics. 1-15. https://doi.org/10.1080/14763141.2021.1902553 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1080/14763141.2021.1902553 es_ES
dc.description.upvformatpinicio 1 es_ES
dc.description.upvformatpfin 15 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.identifier.pmid 34126852 es_ES
dc.relation.pasarela S\449712 es_ES
dc.contributor.funder Ministerio de Economía y Competitividad es_ES
dc.contributor.funder Ministerio de Educación, Cultura y Deporte es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem