A comparative study of computer assited assessment of image quality index for mammographic phantom images

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

A comparative study of computer assited assessment of image quality index for mammographic phantom images

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Mayo Nogueira, Patricia es_ES
dc.contributor.author Ródenas Escribá, Francisco De Asís es_ES
dc.contributor.author Verdú Martín, Gumersindo Jesús es_ES
dc.contributor.author Villaescusa, J.I es_ES
dc.contributor.author Campayo, Juan Manuel es_ES
dc.date.accessioned 2024-02-09T19:01:41Z
dc.date.available 2024-02-09T19:01:41Z
dc.date.issued 2005-12-20 es_ES
dc.identifier.issn 0144-8420 es_ES
dc.identifier.uri http://hdl.handle.net/10251/202515
dc.description.abstract [EN] Mammographic phantom images are usually used to study the quality of images obtained by dedicated mammographic equipment. The digital image treatment techniques allow us to carry out an automatic analysis of the phantom image. In this work, some techniques of digital image processing are applied to compute a specific image quality index (IQI) for a mammographic phantom, namely CIRS model 11A version SP01. The algorithm designed analyses the phantom image by means of automatic detection of the number of microcalcifications, and the image resolution as the number of line pairs per millimetre. Then, the IQI is calculated from a scoring system. The manner in which the functioning conditions (kV and mAs) of the mammographic equipment and the preprocessing denoising method of the digital image affect the results for the IQI are also studied. es_ES
dc.language Inglés es_ES
dc.publisher Oxford University Press es_ES
dc.relation.ispartof Radiation Protection Dosimetry es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Radiology es_ES
dc.subject Nuclear Medicine es_ES
dc.subject Medical Imaging es_ES
dc.subject.classification MATEMATICA APLICADA es_ES
dc.subject.classification INGENIERIA NUCLEAR es_ES
dc.title A comparative study of computer assited assessment of image quality index for mammographic phantom images es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1093/rpd/nci222 es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Arquitectura - Escola Tècnica Superior d'Arquitectura es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Mayo Nogueira, P.; Ródenas Escribá, FDA.; Verdú Martín, GJ.; Villaescusa, J.; Campayo, JM. (2005). A comparative study of computer assited assessment of image quality index for mammographic phantom images. Radiation Protection Dosimetry. 116(1):620-623. https://doi.org/10.1093/rpd/nci222 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1093/rpd/nci222 es_ES
dc.description.upvformatpinicio 620 es_ES
dc.description.upvformatpfin 623 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 116 es_ES
dc.description.issue 1 es_ES
dc.identifier.pmid 16604712 es_ES
dc.relation.pasarela S\28135 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem