Strip-based lateral flow-type indicator displacement assay for gamma-hydroxybutyric acid (GHB) detection in beverages

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Strip-based lateral flow-type indicator displacement assay for gamma-hydroxybutyric acid (GHB) detection in beverages

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Garrido-García, Eva María es_ES
dc.contributor.author Hernández-Sigüenza, Guillermo es_ES
dc.contributor.author Climent Terol, Estela es_ES
dc.contributor.author Marcos Martínez, María Dolores es_ES
dc.contributor.author Rurack, Knut es_ES
dc.contributor.author Gaviña, Pablo es_ES
dc.contributor.author Parra, Margarita es_ES
dc.contributor.author Sancenón Galarza, Félix es_ES
dc.contributor.author Martí-Centelles, Vicente es_ES
dc.contributor.author Martínez-Máñez, Ramón es_ES
dc.date.accessioned 2024-02-29T19:03:01Z
dc.date.available 2024-02-29T19:03:01Z
dc.date.issued 2023-02-15 es_ES
dc.identifier.issn 0925-4005 es_ES
dc.identifier.uri http://hdl.handle.net/10251/202854
dc.description.abstract [EN] The use of gamma-hydroxybutyric acid (GHB) in drug-facilitated sexual assault has increased due to its availability and high solubility in aqueous solutions and alcoholic beverages, necessitating the development of rapid methods for GHB detection. In this respect, portable testing methods for use in the field, based on lateral flow assays (LFAs) and capable of detecting trace concentrations of target analytes, are particularly attractive and hold enormous potential for the detection of illicit drugs. Using this strategy, here we report a rapid, low cost, easy-tohandle strip-based LFA for GHB analysis employing a smartphone for fluorescence readout. At molecular signalling level, the ensemble is based on a Cu2+ complex with a tetradentate ligand and the fluorescent dye coumarin 343, which indicate GHB through an indicator displacement assay (IDA) in aqueous solution. When incorporated in a LFA-based strip test this system shows a detection limit as low as 0.03 mu M for GHB in MES buffer solution and is able to detect GHB at concentrations of 0.1 mu M in soft drinks and alcoholic beverages in only 1 min. es_ES
dc.description.sponsorship This research was funded by the Ministerio de Ciencia, Innovacion y Universidades (Spanish Government), the Agencia Estatal de Investigacion (AEI), the European Union (PID2021-126304OB-C41) (MCIU/AEI/FEDER, EU), the Conselleria de Innovacion, Universidades, Ciencia y Sociedad Digital, Generalitat Valenciana (PROMETEO CIPROM/2021/007) and the German Research Foundation (DFG; CL 761/1-19). This work was also supported by CIBER-Consorcio Centro de Investigacion Biomedica en Red (CB06/01/2012), Instituto de Salud Carlos III, Ministerio de Ciencia e Innovacion. E. G. is grateful to the Spanish MEC for her FPU grant (FPU16/02464). G. H. thanks to Generalitat Valenciana for his pre-doctoral grant (ACIF/2021/204). V. M.-C. thanks the financial support from Generalitat Valenciana (CIDEGENT/2020/031). es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Sensors and Actuators B Chemical es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Fluorescent dyes es_ES
dc.subject Indicator displacement assay (IDA) es_ES
dc.subject Gamma-hydroxybutyric acid (GHB) es_ES
dc.subject Lateral flow assay es_ES
dc.subject Test strip es_ES
dc.subject Smartphone readout es_ES
dc.subject.classification QUIMICA ORGANICA es_ES
dc.subject.classification QUIMICA INORGANICA es_ES
dc.title Strip-based lateral flow-type indicator displacement assay for gamma-hydroxybutyric acid (GHB) detection in beverages es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.snb.2022.133043 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023/PID2021-126304OB-C41/ES/NUEVOS MATERIALES Y SONDAS PARA EL RECONOCIMIENTO, LIBERACION DE FARMACOS, NANOMOTORES Y COMUNICACION/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MECD//FPU16%2F02464/ES/FPU16%2F02464/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GV INNOV.UNI.CIENCIA//CIDEGENT%2F2020%2F031//AYUDA CONTRATO CIDEGENT-MARTI CENTELLES/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GENERALITAT VALENCIANA//CIPROM%2F2021%2F007//ADVANCED MOLECULAR PROBES, SENSORS AND NANOPARTICLES FOR CONTROLLED RELEASE APPLICATIONS/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GENERALITAT VALENCIANA//ACIF%2F2021%2F204//SONDAS MOLECULARES NO INVASIVAS PARA LA DETECCION DE MARCADORES BIOLOGICOS DE DIFERENTES PATOLOGIAS/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GV INNOV.UNI.CIENCIA//CIDEGENT%2F2020%2F031//CAJAS ORGANICAS COMO CONTENEDORES PARA LIBERACION DIRIGIDA DE FARMACOS EN TERAPIA CONTRA EL CANCER/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/DFG//CL 761%2F1-19/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/ISCIII//CB06%2F01%2F2012//CIBER-BBN / es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny es_ES
dc.description.bibliographicCitation Garrido-García, EM.; Hernández-Sigüenza, G.; Climent Terol, E.; Marcos Martínez, MD.; Rurack, K.; Gaviña, P.; Parra, M.... (2023). Strip-based lateral flow-type indicator displacement assay for gamma-hydroxybutyric acid (GHB) detection in beverages. Sensors and Actuators B Chemical. 377. https://doi.org/10.1016/j.snb.2022.133043 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1016/j.snb.2022.133043 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 377 es_ES
dc.relation.pasarela S\482931 es_ES
dc.contributor.funder GENERALITAT VALENCIANA es_ES
dc.contributor.funder MINISTERIO DE EDUCACION es_ES
dc.contributor.funder Instituto de Salud Carlos III es_ES
dc.contributor.funder Deutsche Forschungsgemeinschaft es_ES
dc.contributor.funder AGENCIA ESTATAL DE INVESTIGACION es_ES
dc.contributor.funder Universitat Politècnica de València es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem