Mostrar el registro sencillo del ítem
dc.contributor.author | Garrido-García, Eva María | es_ES |
dc.contributor.author | Hernández-Sigüenza, Guillermo | es_ES |
dc.contributor.author | Climent Terol, Estela | es_ES |
dc.contributor.author | Marcos Martínez, María Dolores | es_ES |
dc.contributor.author | Rurack, Knut | es_ES |
dc.contributor.author | Gaviña, Pablo | es_ES |
dc.contributor.author | Parra, Margarita | es_ES |
dc.contributor.author | Sancenón Galarza, Félix | es_ES |
dc.contributor.author | Martí-Centelles, Vicente | es_ES |
dc.contributor.author | Martínez-Máñez, Ramón | es_ES |
dc.date.accessioned | 2024-02-29T19:03:01Z | |
dc.date.available | 2024-02-29T19:03:01Z | |
dc.date.issued | 2023-02-15 | es_ES |
dc.identifier.issn | 0925-4005 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/202854 | |
dc.description.abstract | [EN] The use of gamma-hydroxybutyric acid (GHB) in drug-facilitated sexual assault has increased due to its availability and high solubility in aqueous solutions and alcoholic beverages, necessitating the development of rapid methods for GHB detection. In this respect, portable testing methods for use in the field, based on lateral flow assays (LFAs) and capable of detecting trace concentrations of target analytes, are particularly attractive and hold enormous potential for the detection of illicit drugs. Using this strategy, here we report a rapid, low cost, easy-tohandle strip-based LFA for GHB analysis employing a smartphone for fluorescence readout. At molecular signalling level, the ensemble is based on a Cu2+ complex with a tetradentate ligand and the fluorescent dye coumarin 343, which indicate GHB through an indicator displacement assay (IDA) in aqueous solution. When incorporated in a LFA-based strip test this system shows a detection limit as low as 0.03 mu M for GHB in MES buffer solution and is able to detect GHB at concentrations of 0.1 mu M in soft drinks and alcoholic beverages in only 1 min. | es_ES |
dc.description.sponsorship | This research was funded by the Ministerio de Ciencia, Innovacion y Universidades (Spanish Government), the Agencia Estatal de Investigacion (AEI), the European Union (PID2021-126304OB-C41) (MCIU/AEI/FEDER, EU), the Conselleria de Innovacion, Universidades, Ciencia y Sociedad Digital, Generalitat Valenciana (PROMETEO CIPROM/2021/007) and the German Research Foundation (DFG; CL 761/1-19). This work was also supported by CIBER-Consorcio Centro de Investigacion Biomedica en Red (CB06/01/2012), Instituto de Salud Carlos III, Ministerio de Ciencia e Innovacion. E. G. is grateful to the Spanish MEC for her FPU grant (FPU16/02464). G. H. thanks to Generalitat Valenciana for his pre-doctoral grant (ACIF/2021/204). V. M.-C. thanks the financial support from Generalitat Valenciana (CIDEGENT/2020/031). | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Sensors and Actuators B Chemical | es_ES |
dc.rights | Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) | es_ES |
dc.subject | Fluorescent dyes | es_ES |
dc.subject | Indicator displacement assay (IDA) | es_ES |
dc.subject | Gamma-hydroxybutyric acid (GHB) | es_ES |
dc.subject | Lateral flow assay | es_ES |
dc.subject | Test strip | es_ES |
dc.subject | Smartphone readout | es_ES |
dc.subject.classification | QUIMICA ORGANICA | es_ES |
dc.subject.classification | QUIMICA INORGANICA | es_ES |
dc.title | Strip-based lateral flow-type indicator displacement assay for gamma-hydroxybutyric acid (GHB) detection in beverages | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.snb.2022.133043 | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023/PID2021-126304OB-C41/ES/NUEVOS MATERIALES Y SONDAS PARA EL RECONOCIMIENTO, LIBERACION DE FARMACOS, NANOMOTORES Y COMUNICACION/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MECD//FPU16%2F02464/ES/FPU16%2F02464/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GV INNOV.UNI.CIENCIA//CIDEGENT%2F2020%2F031//AYUDA CONTRATO CIDEGENT-MARTI CENTELLES/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GENERALITAT VALENCIANA//CIPROM%2F2021%2F007//ADVANCED MOLECULAR PROBES, SENSORS AND NANOPARTICLES FOR CONTROLLED RELEASE APPLICATIONS/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GENERALITAT VALENCIANA//ACIF%2F2021%2F204//SONDAS MOLECULARES NO INVASIVAS PARA LA DETECCION DE MARCADORES BIOLOGICOS DE DIFERENTES PATOLOGIAS/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GV INNOV.UNI.CIENCIA//CIDEGENT%2F2020%2F031//CAJAS ORGANICAS COMO CONTENEDORES PARA LIBERACION DIRIGIDA DE FARMACOS EN TERAPIA CONTRA EL CANCER/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/DFG//CL 761%2F1-19/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/ISCIII//CB06%2F01%2F2012//CIBER-BBN / | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny | es_ES |
dc.description.bibliographicCitation | Garrido-García, EM.; Hernández-Sigüenza, G.; Climent Terol, E.; Marcos Martínez, MD.; Rurack, K.; Gaviña, P.; Parra, M.... (2023). Strip-based lateral flow-type indicator displacement assay for gamma-hydroxybutyric acid (GHB) detection in beverages. Sensors and Actuators B Chemical. 377. https://doi.org/10.1016/j.snb.2022.133043 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | https://doi.org/10.1016/j.snb.2022.133043 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 377 | es_ES |
dc.relation.pasarela | S\482931 | es_ES |
dc.contributor.funder | GENERALITAT VALENCIANA | es_ES |
dc.contributor.funder | MINISTERIO DE EDUCACION | es_ES |
dc.contributor.funder | Instituto de Salud Carlos III | es_ES |
dc.contributor.funder | Deutsche Forschungsgemeinschaft | es_ES |
dc.contributor.funder | AGENCIA ESTATAL DE INVESTIGACION | es_ES |
dc.contributor.funder | Universitat Politècnica de València | es_ES |