Técnicas de monitorización de la corrosión y su aplicación en estructuras nuevas y rehabilitadas: análisis de la velocidad y potencial de corrosión.

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Técnicas de monitorización de la corrosión y su aplicación en estructuras nuevas y rehabilitadas: análisis de la velocidad y potencial de corrosión.

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Calderón García, Pedro Antonio es_ES
dc.contributor.author Florez Sanchez, Wendy Vanesa es_ES
dc.date.accessioned 2024-04-27T23:28:29Z
dc.date.available 2024-04-27T23:28:29Z
dc.date.created 2024-04-10
dc.date.issued 2024-04-28 es_ES
dc.identifier.uri http://hdl.handle.net/10251/203819
dc.description.abstract [ES] En el presente Trabajo de Fin de Máster se aborda la corrosión en estructuras de hormigón armado, tanto en edificios nuevos como rehabilitados. La corrosión representa una amenaza para la durabilidad y seguridad de estas estructuras, lo que a menudo resulta en costosas intervenciones de reparación o reemplazo. Se explica que la corrosión puede ocurrir cuando la capa protectora de óxido en las armaduras se deteriora debido a la carbonatación del hormigón o la presencia de cloruros. Los efectos de la corrosión son generalmente imperceptibles hasta que el daño es significativo, lo que resalta la importancia de la detección temprana y el monitoreo continuo. El trabajo se centra en el uso de sensores electroquímicos para medir la velocidad y el potencial de corrosión como parámetros clave para evaluar el estado de las estructuras. Se mencionan dos edificios específicos: un aparcamiento subterráneo rehabilitado en Plaza de la Reina de Valencia y el edificio de Distrito Digital del Puerto de Alicante, donde se han instalado sistemas de monitorización. El estudio destaca la importancia de los avances en tecnología de sensores para la detección temprana y el monitoreo continuo de la corrosión, lo que permite inspecciones no destructivas. El trabajo tiene como objetivo general investigar y analizar las técnicas de monitorización de corrosión y su aplicabilidad en estructuras nuevas y rehabilitadas. Se presenta un estado del arte sobre el tema, se describe la monitorización en los dos edificios mencionados y se compara con normativas y recomendaciones existentes. Los resultados confirman la utilidad de esta técnica y proporcionan una base para futuras investigaciones y aplicaciones prácticas. es_ES
dc.description.abstract [EN] This master s Thesis addresses corrosion in reinforced concrete structures, both in new and rehabilitated buildings. Corrosion represents a threat to the durability and safety of these structures, often resulting in costly repair or replacement interventions. It is explained that corrosion can occur when the protective oxide layer on reinforcement deteriorates due to carbonation of the concrete or the presence of chlorides. The effects of corrosion are generally imperceptible until damage is significant, highlighting the importance of early detection and continuous monitoring. The work focuses on the use of electrochemical sensors to measure corrosion rate and potential as key parameters to evaluate the state of structures. Two specific buildings are mentioned: a rehabilitated underground car park in Plaza de la Reina in Valencia and the Digital District building of the Port of Alicante, where monitoring systems have been installed. The study highlights the importance of advances in sensor technology for early detection and continuous monitoring of corrosion, enabling non-destructive inspections. The general objective of the work is to investigate and analyze corrosion monitoring techniques and their applicability in new and rehabilitated structures. A state of the art on the subject is presented, the monitoring in the two mentioned buildings is described and compared with existing regulations and recommendations. The results confirm the usefulness of this technique and provide a basis for future research and practical applications. es_ES
dc.format.extent 127 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Fibra óptica es_ES
dc.subject Velocidad de corrosión es_ES
dc.subject Potencial de corrosión es_ES
dc.subject Hormigón armado es_ES
dc.subject Monitorización es_ES
dc.subject Corrosion rate es_ES
dc.subject Corrosion potential es_ES
dc.subject Reinforced concrete es_ES
dc.subject Monitoring es_ES
dc.subject Fiber optics es_ES
dc.subject.classification INGENIERIA DE LA CONSTRUCCION es_ES
dc.subject.other Máster Universitario en Ingeniería del Hormigón-Màster Universitari en Enginyeria del Formigó es_ES
dc.title Técnicas de monitorización de la corrosión y su aplicación en estructuras nuevas y rehabilitadas: análisis de la velocidad y potencial de corrosión. es_ES
dc.title.alternative Corrosion monitoring techniques and their application in new and rehabilitated structures: analysis of corrosion rate and potential. es_ES
dc.title.alternative Les tècniques de monitorització de la corrosió i la seua aplicació en estructures noves i rehabilitades: anàlisi de la velocitat i potencial de corrosió. es_ES
dc.type Tesis de máster es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería de la Construcción y de Proyectos de Ingeniería Civil - Departament d'Enginyeria de la Construcció i de Projectes d'Enginyeria Civil es_ES
dc.description.bibliographicCitation Florez Sanchez, WV. (2024). Técnicas de monitorización de la corrosión y su aplicación en estructuras nuevas y rehabilitadas: análisis de la velocidad y potencial de corrosión. Universitat Politècnica de València. http://hdl.handle.net/10251/203819 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\160229 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem