- -

Design, establishment, analysis, and quality control of a high-precision reference frame in Cortes de Pallás (Spain)

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Design, establishment, analysis, and quality control of a high-precision reference frame in Cortes de Pallás (Spain)

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author García-Asenjo Villamayor, Luis es_ES
dc.contributor.author Martínez, Laura es_ES
dc.contributor.author Baselga Moreno, Sergio es_ES
dc.contributor.author Garrigues, Pascual es_ES
dc.contributor.author Luján, Raquel es_ES
dc.date.accessioned 2024-05-17T18:06:19Z
dc.date.available 2024-05-17T18:06:19Z
dc.date.issued 2023-06 es_ES
dc.identifier.issn 1866-9298 es_ES
dc.identifier.uri http://hdl.handle.net/10251/204240
dc.description.abstract [EN] A high-precision geodetic reference frame was required in Cortes de Pallas (Spain) to undertake a long-term deformation monitoring project. Involving distances up to 2000 m, the aimed accuracy was 1 mm and 3 mm for horizontal and vertical components, respectively. Such a high precision is necessary to detect possible displacements of selected points on a critical rocky area in a short period of time, i.e., 2 or 3 years, and also to provide ground control for the integration of precise 3D models periodically obtained by remote sensing techniques. Considering the historical geotechnical problems of the area, the possible influence of the hydroelectric power plant, and the peculiar orography of the zone, a proper analysis of the stability is crucial if the reference frame is to be used for rigorous over-time deformation monitoring. This paper describes the deformation monitoring of a 10-pillar geodetic network which was measured from 2018 to 2020 by using a sub-millimetric Mekometer ME5000 (0.2 mm + 0.2 ppm) along with a demanding observing methodology which includes a network of data loggers for temperature, humidity, and air pressure as well as proper calibration of sensors and instruments to prevent potential inconsistencies between the scale of the network and the unit of length of the International System (SI meter). The results demonstrated that the chosen methodology yielded the aimed accuracy. However, using such a high precision methodology entails the problem that small displacements of only 1 or 2 mm are significantly detected as deformations by conventional deformation analysis and then it arises the problem of finding a subset of stable points for a rigorous datum realization when all the points seem to displace. This general problem is analyzed in the particular case of Cortes de Pallas, where a balanced mix of deformation analysis and technical decisions was eventually adopted to define a precise and stable reference frame for rigorous over-time deformation monitoring. es_ES
dc.description.sponsorship Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. es_ES
dc.language Inglés es_ES
dc.publisher Springer es_ES
dc.relation.ispartof Applied Geomatics es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject Geodetic network es_ES
dc.subject Reference frames es_ES
dc.subject Deformation monitoring es_ES
dc.subject Sub-millimetric EDM es_ES
dc.subject ME5000 es_ES
dc.subject Length metrology es_ES
dc.subject.classification INGENIERIA CARTOGRAFICA, GEODESIA Y FOTOGRAMETRIA es_ES
dc.title Design, establishment, analysis, and quality control of a high-precision reference frame in Cortes de Pallás (Spain) es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1007/s12518-022-00481-9 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/UPV-VIN//PAID-01-20-16//Development and validation of novel tropospheric models for a GNSS-Based Distance Meter as applied to length metrology./ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/EURAMET E.V.//18SIB01 GEOMETRE//Large-scale dimensional measurements for geodesy/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería Geodésica, Cartográfica y Topográfica - Escola Tècnica Superior d'Enginyeria Geodèsica, Cartogràfica i Topogràfica es_ES
dc.description.bibliographicCitation García-Asenjo Villamayor, L.; Martínez, L.; Baselga Moreno, S.; Garrigues, P.; Luján, R. (2023). Design, establishment, analysis, and quality control of a high-precision reference frame in Cortes de Pallás (Spain). Applied Geomatics. 15(2):359-370. https://doi.org/10.1007/s12518-022-00481-9 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1007/s12518-022-00481-9 es_ES
dc.description.upvformatpinicio 359 es_ES
dc.description.upvformatpfin 370 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 15 es_ES
dc.description.issue 2 es_ES
dc.relation.pasarela S\487319 es_ES
dc.contributor.funder EURAMET E.V. es_ES
dc.contributor.funder UNIVERSIDAD POLITECNICA DE VALENCIA es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem