- -

Validation of a Qualification Procedure Applied to the Verification of Partial Discharge Analysers Used for HVDC or HVAC Networks

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Validation of a Qualification Procedure Applied to the Verification of Partial Discharge Analysers Used for HVDC or HVAC Networks

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Vera, Carlos es_ES
dc.contributor.author Garnacho, Fernando es_ES
dc.contributor.author Klüss, Joni es_ES
dc.contributor.author Mier, Christian es_ES
dc.contributor.author Álvarez, Fernando es_ES
dc.contributor.author Lahti, Kari es_ES
dc.contributor.author Khamlichi, Abderrahim es_ES
dc.contributor.author Elg, Alf-Peter es_ES
dc.contributor.author Rodrigo Mor, Armando es_ES
dc.contributor.author Arcones, Eduardo es_ES
dc.contributor.author Camuñas, Álvaro es_ES
dc.contributor.author Pakonen, Perti es_ES
dc.contributor.author Ortego, Javier es_ES
dc.contributor.author Vidal, José Ramón es_ES
dc.contributor.author Haider, Miran es_ES
dc.contributor.author Rovira, Jorge es_ES
dc.contributor.author Simón, Pascual es_ES
dc.contributor.author Squicciarini, Antonio es_ES
dc.date.accessioned 2024-06-12T18:18:26Z
dc.date.available 2024-06-12T18:18:26Z
dc.date.issued 2023-07 es_ES
dc.identifier.uri http://hdl.handle.net/10251/205066
dc.description.abstract [EN] The insulation condition of HVDC grids consisting of cable systems, GIS, and converters should be monitored by partial discharge (PD) analysers using artificial intelligence (AI) tools for efficient insulation diagnosis. Although there are many experiences of PD monitoring solutions developed for the supervision of the insulation condition of HVAC grids using PD analysers, there are no standardised requirements for their qualification available yet. The international technical specification TS IEC 62478 provides general rules for PD measurements using electromagnetic methods but does not define performance requirements for qualification tests. HVDC and HVAC PD analysers must be tested by unambiguous test procedures. This paper compiles experiences of using PD analysers with HFCT sensors in HVAC grids (cable systems, GIS, and AIS) to define a qualification procedure for HVAC systems. This procedure is applicable to HVDC grids (cable systems, GIS, AIS, and converters) because the particularities related to the insulation behaviour under HVDC voltage are also considered. Representative PD sources are discussed in HVAC and HVDC positive and negative polarity. The PD pulse trend of representative insulation defects in HVDC cable systems is quite different from that of HVAC grids. Special attention should be paid to the acquisition of PD signals in HVDC grids since few pulses appear in solid insulations, mainly during voltage changes (polarity reversals or surges), but rarely in continuous operation with constant direct voltage. A synthetic PD simulator has been developed to reproduce trains of PD pulses or noise signals, similar to those that can appear in the power network. A set of three functionality tests has been developed for qualification of the diagnostic capabilities of PD analysers working up to 30 MHz addressed to HVDC or HVAC grids: (1) PD recognition test, (2) PD clustering test, and (3) PD location test. This qualification procedure has been validated by means of a round-robin test performed by five research institutes (RISE, FFII, TUDelft, TAU, and UPM) using commercial and in-development AI PD recognition and clustering tools to demonstrate its robustness and applicability. Applying this qualification procedure, two PD methods for electrical detection and prevention of insulation defects have been approved, one for HVAC and the other for HVDC grids. es_ES
dc.description.sponsorship This project 19ENG02 FutureEnergy has received funding from the EMPIR programme co-financed by the Participating States and from the European Union s Horizon 2020 research and innovation programme. es_ES
dc.language Inglés es_ES
dc.publisher MDPI AG es_ES
dc.relation.ispartof Applied Sciences es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject HVDC and HVAC cable system es_ES
dc.subject GIS es_ES
dc.subject Converters es_ES
dc.subject Insulation diagnosis es_ES
dc.subject Qualification procedure es_ES
dc.subject Standardisation es_ES
dc.subject.classification INGENIERIA ELECTRICA es_ES
dc.title Validation of a Qualification Procedure Applied to the Verification of Partial Discharge Analysers Used for HVDC or HVAC Networks es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.3390/app13148214 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/EMPIR//19ENG02 / es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Vera, C.; Garnacho, F.; Klüss, J.; Mier, C.; Álvarez, F.; Lahti, K.; Khamlichi, A.... (2023). Validation of a Qualification Procedure Applied to the Verification of Partial Discharge Analysers Used for HVDC or HVAC Networks. Applied Sciences. 13(14). https://doi.org/10.3390/app13148214 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.3390/app13148214 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 13 es_ES
dc.description.issue 14 es_ES
dc.identifier.eissn 2076-3417 es_ES
dc.relation.pasarela S\497497 es_ES
dc.contributor.funder European Metrology Programme for Innovation and Research es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem