- -

Estudio comparativo de ASL y SUV obtenidos a partir de imágenes de PET-RM en el diagnóstico de patologías neurológicas

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Estudio comparativo de ASL y SUV obtenidos a partir de imágenes de PET-RM en el diagnóstico de patologías neurológicas

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Moratal Pérez, David es_ES
dc.contributor.advisor Vallés Lluch, Ana es_ES
dc.contributor.advisor Romero Martín, Juan Antonio es_ES
dc.contributor.author Pérez Herrero, Judith es_ES
dc.date.accessioned 2024-07-01T15:18:34Z
dc.date.available 2024-07-01T15:18:34Z
dc.date.created 2024-06-13
dc.date.issued 2024-07-01 es_ES
dc.identifier.uri http://hdl.handle.net/10251/205597
dc.description.abstract [ES] Las enfermedades neurológicas, tales como los tumores cerebrales y las afecciones neurodegenerativas, requieren diagnósticos precisos y no invasivos. El flujo sanguíneo cerebral se ajusta según las demandas fisiológicas de cada región cerebral, lo que se conoce como reactividad cerebrovascular. Técnicas como la Arterial Spin Labeling (ASL) y la Tomografía por Emisión de Positrones, junto con Resonancia Magnética (PET-RM), proporcionan información sobre el flujo sanguíneo y el metabolismo cerebral, respectivamente, siendo la PET la técnica de referencia para medir la reactividad cerebrovascular. Sin embargo, la utilización de agentes de contraste, como el gadolinio, puede causar efectos secundarios en pacientes con enfermedades neurológicas. El objetivo del presente Trabajo Fin de Grado es correlacionar los resultados de la medición del flujo sanguíneo cerebral obtenidos mediante PET-RM con los obtenidos a través de ASL, una técnica no invasiva que mapea la perfusión tisular sin el uso de agentes de contraste, utilizando la magnetización del agua sanguínea arterial. En este estudio, se analizarán los datos de ASL y PET-RM de 42 pacientes con diversas enfermedades neurológicas para establecer una correlación entre los valores de perfusión obtenidos mediante ASL y los valores de SUV (Standardized Uptake Value) obtenidos mediante PET-RM. Los datos derivados de las pruebas de ASL serán analizados utilizando el software médico AW Server (General Electric). El proceso consiste en la delineación de dos Regiones de Interés (ROI), una en cada hemisferio, para cada región cerebral (Frontal, Temporal y Parietal). Por otro lado, los datos relativos al metabolismo cerebral se obtendrán mediante la técnica de PET, siendo analizados haciendo uso del software especializado en radiología y medicina nuclear denominado MIM . Una vez realizada la depuración de datos se procederá a realizar un análisis estadístico empleando el entorno de programación MATLAB, con el fin de evaluar las correlaciones entre las áreas cerebrales con hipoperfusión e hipometabolismo. es_ES
dc.description.abstract [EN] Neurological diseases, such as brain tumours and neurodegenerative conditions, require accurate and non-invasive diagnostics. Cerebral blood flow adjusts according to the physiological demands of each brain region, known as cerebrovascular reactivity. Techniques such as Arterial Spin Labeling (ASL) and Positron Emission Tomography, together with Magnetic Resonance Imaging (PET-MRI), provide information on cerebral blood flow and cerebral metabolism, respectively, with PET being the gold standard technique for measuring cerebrovascular reactivity. However, the use of contrast agents, such as gadolinium, can cause side effects in patients with neurological diseases. The aim of this thesis is to correlate the results of cerebral blood flow measurement obtained by PET-MRI with those obtained by ASL, a non-invasive technique that maps tissue perfusion without the use of contrast agents, using the magnetisation of arterial blood water. In this study, ASL and PET-MRI data from 42 patients with various neurological diseases will be analysed to establish a correlation between perfusion values obtained by ASL and SUV (Standardised Uptake Value) values obtained by PET-MRI. The data derived from the ASL tests will be analysed using the medical software "AW Server" (General Electric). The process consists of the delineation of two Regions of Interest (ROI), one in each hemisphere, for each brain region (Frontal, Temporal and Parietal). On the other hand, the data relating to brain metabolism will be obtained by means of the PET technique and analysed using the specialised radiology and nuclear medicine software called "MIM". Once the data have been cleaned, a statistical analysis will be carried out using the MATLAB programming environment in order to evaluate the correlations between brain areas with hypoperfusion and hypometabolism. es_ES
dc.format.extent 109 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject ASL es_ES
dc.subject PET-RM es_ES
dc.subject CBF es_ES
dc.subject Enfermedades neurológicas es_ES
dc.subject Resonancia magnética es_ES
dc.subject Correlación es_ES
dc.subject PET-MRI es_ES
dc.subject Neurological diseases es_ES
dc.subject Magnetic resonance imaging es_ES
dc.subject Correlation es_ES
dc.subject.classification MAQUINAS Y MOTORES TERMICOS es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.subject.other Grado en Ingeniería Biomédica-Grau en Enginyeria Biomèdica es_ES
dc.title Estudio comparativo de ASL y SUV obtenidos a partir de imágenes de PET-RM en el diagnóstico de patologías neurológicas es_ES
dc.title.alternative Comparative study of ASL and SUV from PET-MR images in the diagnosis of neurological pathologies. es_ES
dc.title.alternative Estudi comparatiu d ASL i SUV obtinguts a partir d imatges de PET-RM al diagnòstic de patologies neurològiques es_ES
dc.type Proyecto/Trabajo fin de carrera/grado es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Pérez Herrero, J. (2024). Estudio comparativo de ASL y SUV obtenidos a partir de imágenes de PET-RM en el diagnóstico de patologías neurológicas. Universitat Politècnica de València. http://hdl.handle.net/10251/205597 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\163796 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem