Mostrar el registro sencillo del ítem
dc.contributor.advisor | Martón Lluch, Isabel | es_ES |
dc.contributor.advisor | La Fleur, Lina | es_ES |
dc.contributor.advisor | Mosfegh, Bahram | es_ES |
dc.contributor.author | Tévar Garcilópez, Javier | es_ES |
dc.date.accessioned | 2024-07-22T09:54:55Z | |
dc.date.available | 2024-07-22T09:54:55Z | |
dc.date.created | 2024-06-20 | |
dc.date.issued | 2024-07-22 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/206495 | |
dc.description.abstract | [ES] El objetivo principal de esta tesis es llevar a cabo un análisis comparativo de la configuración predominante de los paneles fotovoltaicos dentro de un sistema establecido orientado al sur, en comparación con varios escenarios alternativos caracterizados por modificaciones en la orientación y los ángulos de inclinación de los paneles. También se pretende estudiar teóricamente la posibilidad de implantar una cubierta verde en las nuevas instalaciones fotovoltaicas de la zona. Para ello, se emplea un enfoque sistemático que abarca varios pasos fundamentales. En primer lugar, se realiza una exhaustiva revisión bibliográfica que abarca los principios fundamentales de los sistemas fotovoltaicos. La revisión aclara los fundamentos de la tecnología fotovoltaica y también proporciona una visión cualitativa de los conceptos esenciales relacionados con las cubiertas verdes y vivas, incluidos sus beneficios inherentes, componentes y diversas tipologías. Además, se explora en profundidad la bibliografía existente sobre la aplicación combinada de ambos conceptos. Esta revisión también abarca un examen del impacto de las orientaciones divergentes en los paneles solares, analizando cómo influyen tales alteraciones en la producción de electricidad. La perspectiva sueca también se tiene en cuenta en esta revisión bibliográfica, donde las cambiantes condiciones climáticas, como la nieve durante los meses de invierno, afectan a los sistemas fotovoltaicos. A continuación, se modela meticulosamente un sistema fotovoltaico existente. Tras la validación, que consiste en garantizar que la instalación modelizada se aproxima al comportamiento del sistema real en términos de generación de electricidad, se introducen modificaciones para explorar el impacto de diversas configuraciones. Esto incluye variar las orientaciones y el ángulo de inclinación de los paneles solares dentro de la configuración existente. Los análisis posteriores aclaran estos efectos, lo que permite la formulación de observaciones concluyentes. | es_ES |
dc.description.abstract | [EN] The global commitment to renewable energy is steadily intensifying, with a notable surge in the adoption of photovoltaic solar energy. This growth can be attributed in part to the decreasing costs of photovoltaic systems and the inherent volatility of fossil fuel prices. Furthermore, the mounting trend of deploying photovoltaic solar energy systems in building rooftops has gained prominence. This approach capitalizes on otherwise underutilized spaces and contributes to electricity production. Additionally, research has demonstrated that augmenting conventional systems with alternatives, such as green roofs and varied solar modules orientations, can yield additional benefits. This thesis is dedicated to an exploration of the feasibility of altering the orientation of certain solar modules within an existing installation, including adjustments in both azimuth and tilt angles. The selected methodology involves two key phases: initially, studying the characteristics of the current photovoltaic system to evaluate its efficiency, and subsequently, leveraging the capabilities of a photovoltaic software. This software facilitates a comprehensive examination of these possibilities by manipulating various parameters within the model. Thus, the simulated model was first validated using real annual electricity production data, and then diverse alternatives were studied to evaluate their impact on electricity production. What is more, it was also theoretically explored the possibility to implement a green roof in a new photovoltaic system in the area. The results showed that, for the specific characteristics of the building under study, a potential increase of 3.41% in annual electricity production could be achieved by modifying modules inclined at an angle of 13ᵒ and spaced 1.6 meters to an inclination angle of 35ᵒ and a spacing of 4.8 meters. Furthermore, it was observed that orienting the modules towards the east and/or west, while yielding a lower peak daily electricity production, provided a more uniform daily production curve, thereby facilitating higher production levels during the early and/or late hours of the day. In addition, it was also concluded that combining a green roof with a new photovoltaic system could increase the annual electricity production, especially during summer months. In summary, the current photovoltaic system is correctly designed and operates efficiently, although it can be enhanced to further augment its electricity production. | es_ES |
dc.format.extent | 121 | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Universitat Politècnica de València | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Sistema solar fotovoltaico | es_ES |
dc.subject | Módulos solares | es_ES |
dc.subject | Producción de electricidad | es_ES |
dc.subject | Cubiertas verdes. | es_ES |
dc.subject | Solar PV system | es_ES |
dc.subject | Solar modules | es_ES |
dc.subject | Electricity production | es_ES |
dc.subject | Green roofs. | es_ES |
dc.subject.classification | ESTADISTICA E INVESTIGACION OPERATIVA | es_ES |
dc.subject.other | Máster Universitario en Ingeniería Industrial-Màster Universitari en Enginyeria Industrial | es_ES |
dc.title | Examination of diverse alternatives for a solar PV system at Linköping University | es_ES |
dc.title.alternative | Estudio de diversas alternativas para un sistema solar fotovoltaico en la Universidad de Linköping | es_ES |
dc.title.alternative | Estudi de diverses alternatives per a un sistema solar fotovoltaic en la Universitat de Linköping | es_ES |
dc.type | Tesis de máster | es_ES |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Estadística e Investigación Operativa Aplicadas y Calidad - Departament d'Estadística i Investigació Operativa Aplicades i Qualitat | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials | es_ES |
dc.description.bibliographicCitation | Tévar Garcilópez, J. (2024). Examination of diverse alternatives for a solar PV system at Linköping University. Universitat Politècnica de València. http://hdl.handle.net/10251/206495 | es_ES |
dc.description.accrualMethod | TFGM | es_ES |
dc.relation.pasarela | TFGM\161575 | es_ES |