Development of an online optical prototype for the simultaneous analysis of defects or gels in industrially synthesized polypropylene films. Part 1: Comparison with ASTM D 3351-93 methods

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Development of an online optical prototype for the simultaneous analysis of defects or gels in industrially synthesized polypropylene films. Part 1: Comparison with ASTM D 3351-93 methods

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Hernández-Fernández, Joaquín es_ES
dc.contributor.author Ortiz, Katherine es_ES
dc.contributor.author López-Martínez, Juan es_ES
dc.date.accessioned 2024-09-06T18:16:44Z
dc.date.available 2024-09-06T18:16:44Z
dc.date.issued 2024-06 es_ES
dc.identifier.uri http://hdl.handle.net/10251/207625
dc.description.abstract [EN] Polypropylene (PP) films are crucial in various industrial applications, from packaging to medical products. However, a common challenge in PP manufacturing is the presence of gel-like defects. These gels are minor defects on the surface of the films that significantly affect the physicochemical, mechanical, and organoleptic properties of the films, compromising the quality of the final product. This first research focuses on developing and validating an in -line optical method to replace the international method ASTM D 3351-93. The main objective was to create a methodology that has the same scope and analytical performance as those reported by ASTM D 3351-93 in such a way that it can compete with it in terms of precision and accuracy, thus allowing end users to this ASTM, such as PP producers, PP marketers, PP film producers, among others internationally, can use this new methodology with necessary analytical support. This analytical methodology integrates the PP extrusion zones, the film processing stages, and the optical zone for reading and processing analytical data. Additionally, it has the advantage of working with a sample size that is even more representative of the population and has less human error since only one operator is required to carry out the test; this method also has much shorter response times. The developed prototype had 14 online stages that allowed representative quantities of samples to be taken and processed thermally and mechanically for ideal optical measurement. For the online method, a 6-point calibration curve is carried out at concentrations of 40, 10, 5, 2, 1 and 0 ppm for the gel or defect sizes of 200, 400, 500, 600, 700, 800 and 900 mu m, show ing excellent linearity where the correlation coefficient varied between 0.997 and 0.999, the limits detection (LOD) varied between 0.85 and 2.61 and the limits of quantification (LOQ) ranged between 2.82 and 8.71. The statistical analyzes by ANOVA of the comparison between the ASTM D 3351-93 method and the proposed simultaneous method indicate that the p value of the evaluation of the means was 0.946, which suggests that the means are not statistically different. To complement, the Tukey test was carried out at 95 %, indicating that the methods have statistical equivalence. center dot Process optimization center dot Determination of defects or in PP films es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof MethodsX es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject Gels es_ES
dc.subject Polypropylene films es_ES
dc.subject.classification CIENCIA DE LOS MATERIALES E INGENIERIA METALURGICA es_ES
dc.title Development of an online optical prototype for the simultaneous analysis of defects or gels in industrially synthesized polypropylene films. Part 1: Comparison with ASTM D 3351-93 methods es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.mex.2024.102688 es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Politécnica Superior de Alcoy - Escola Politècnica Superior d'Alcoi es_ES
dc.description.bibliographicCitation Hernández-Fernández, J.; Ortiz, K.; López-Martínez, J. (2024). Development of an online optical prototype for the simultaneous analysis of defects or gels in industrially synthesized polypropylene films. Part 1: Comparison with ASTM D 3351-93 methods. MethodsX. 12. https://doi.org/10.1016/j.mex.2024.102688 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1016/j.mex.2024.102688 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 12 es_ES
dc.identifier.eissn 2215-0161 es_ES
dc.identifier.pmid 38595807 es_ES
dc.identifier.pmcid PMC11001762 es_ES
dc.relation.pasarela S\523327 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem