Evaluación de técnicas de climatización para viviendas de bajo consumo energético. Diseño para la vivienda Escalà

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Evaluación de técnicas de climatización para viviendas de bajo consumo energético. Diseño para la vivienda Escalà

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Gómez Navarro, Tomás es_ES
dc.contributor.author Gil Alhama, José Antonio es_ES
dc.date.accessioned 2024-10-14T14:10:42Z
dc.date.available 2024-10-14T14:10:42Z
dc.date.created 2024-09-10
dc.date.issued 2024-10-14 es_ES
dc.identifier.uri http://hdl.handle.net/10251/210086
dc.description.abstract [ES] En la sociedad contemporánea, la gestión energética y la contaminación ambiental representan desafíos significativos. La creciente demanda energética de los edificios es un tema alarmante. Se centran esfuerzos en la exploración de alternativas viables para reducir el consumo energético. En este contexto, la vivienda juega un papel fundamental en la mitigación y adaptación al cambio climático, dado que sus emisiones directas e indirectas pueden suponer gran parte de las emisiones globales. El cambio climático, el aumento de las temperaturas, la reducción de emisiones de gases de efecto invernadero en la atmosfera y la mejora de condiciones de confort en el interior de las viviendas son los factores considerados durante la elaboración del presente proyecto. En el presente proyecto, se explica la aplicación de soluciones de climatización y ventilación con un impacto energético y ambiental mínimo, capitalizando las ventajas del clima mediterráneo del barrio de El Cabanyal mediante la implementación de medidas tanto activas como pasivas, y la integración de energías renovables en la comunidad. En este sentido, se propone un diseño de HVAC que optimiza la demanda energética del edificio, priorizando sistemas con bajo consumo eléctrico. Se descartan calderas de gas y eléctricas en busca de la máxima eficiencia y menor impacto ambiental. Además, se introduce un sistema de climatización pasiva denominado XALOC, con el fin de reducir la dependencia de la climatización activa. Se proyecta una reducción significativa del consumo de calefacción y refrigeración, representando el 57% de la demanda total de energía en los edificios del barrio. Estos sistemas HVAC están diseñados para alcanzar un rendimiento óptimo, con una reducción promedio del 48% en el consumo durante el verano y del 37% en invierno, en comparación con un diseño convencional, y se calculará el impacto de cada medida en la reducción del consumo final de electricidad para calefacción, refrigeración y producción de agua caliente sanitaria. es_ES
dc.description.abstract [EN] In contemporary society, energy management and environmental pollution pose significant challenges. The increasing energy demand of buildings is an alarming issue, leading to efforts focused on exploring viable alternatives to reduce energy consumption. In this context, housing plays a crucial role in mitigating and adapting to climate change, as its direct and indirect emissions can constitute a substantial portion of global emissions. Climate change, rising temperatures, reduction of greenhouse gas emissions in the atmosphere, and improvement of indoor comfort conditions are the factors considered in the development of this project. In this project, the implementation of heating, ventilation, and air conditioning (HVAC) solutions with minimal energy and environmental impact is explained, leveraging the advantages of the Mediterranean climate of the El Cabanyal neighborhood through the application of both active and passive measures, as well as the integration of renewable energies within the community. In this regard, an HVAC design is proposed that optimizes the building's energy demand, prioritizing systems with low electricity consumption. Gas and electric boilers are excluded in pursuit of maximum efficiency and minimal environmental impact. Additionally, a passive climate control system called XALOC is introduced to reduce reliance on active climate control. A significant reduction in heating and cooling consumption is projected, accounting for 57% of the total energy demand in buildings in the neighborhood. These HVAC systems are designed to achieve optimal performance, with an average reduction of 48% in summer and 37% in winter, compared to a conventional design. The impact of each measure on the final electricity consumption for heating, cooling, and domestic hot water production will be calculated. es_ES
dc.format.extent 76 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject ESCALÀ es_ES
dc.subject XALOC es_ES
dc.subject SOLAR DECATHLON EUROPE es_ES
dc.subject TRADICIÓN VALENCIANA es_ES
dc.subject BARRIO EL CABANYAL es_ES
dc.subject BARRACA es_ES
dc.subject EFICIENCIA ENERGÉTICA es_ES
dc.subject INNOVACIÓN es_ES
dc.subject CLIMATIZACIÓN PASIVA es_ES
dc.subject CLIMATIZACIÓN ACTIVA es_ES
dc.subject CALOR LATENTE es_ES
dc.subject MATERIAL DE CAMBIO DE FASE es_ES
dc.subject Valencian tradition es_ES
dc.subject El Cabanyal neighborhood es_ES
dc.subject Energy efficiency es_ES
dc.subject Innovation es_ES
dc.subject Passive air conditioning es_ES
dc.subject Active air conditioning es_ES
dc.subject Latent heat es_ES
dc.subject Phase change material es_ES
dc.subject.classification PROYECTOS DE INGENIERIA es_ES
dc.subject.other Grado en Ingeniería de la Energía-Grau en Enginyeria de l'Energia es_ES
dc.title Evaluación de técnicas de climatización para viviendas de bajo consumo energético. Diseño para la vivienda Escalà es_ES
dc.title.alternative Evaluation of air conditioning techniques for low energy consumption homes. Design for the Escalà home es_ES
dc.title.alternative Avaluació de tècniques de climatització per a habitatges de baix consum energètic. Disseny per a l'habitatge Escalà es_ES
dc.type Proyecto/Trabajo fin de carrera/grado es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Proyectos de Ingeniería - Departament de Projectes d'Enginyeria es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Gil Alhama, JA. (2024). Evaluación de técnicas de climatización para viviendas de bajo consumo energético. Diseño para la vivienda Escalà. Universitat Politècnica de València. http://hdl.handle.net/10251/210086 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\165337 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem