- -

Low field slice-selective ZTE imaging of ultra-short T2 tissues based on spin-locking.

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Low field slice-selective ZTE imaging of ultra-short T2 tissues based on spin-locking.

Mostrar el registro completo del ítem

Borreguero-Morata, J.; Galve-Conde, F.; Algarín-Guisado, JM.; Benlloch Baviera, JM.; Alonso-Otamendi, J. (2023). Low field slice-selective ZTE imaging of ultra-short T2 tissues based on spin-locking. Scientific Reports. 13(1). https://doi.org/10.1038/s41598-023-28640-x

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/210790

Ficheros en el ítem

Metadatos del ítem

Título: Low field slice-selective ZTE imaging of ultra-short T2 tissues based on spin-locking.
Autor: Borreguero-Morata, José Galve-Conde, Fernando Algarín-Guisado, José Miguel Benlloch Baviera, Jose María Alonso-Otamendi, Joseba
Entidad UPV: Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular
Fecha difusión:
Resumen:
[EN] Magnetic Resonance Imaging of hard biological tissues is very challenging due to small proton abundance and ultra-short T-2 decay times, especially at low magnetic fields, where sample magnetization is weak. While ...[+]
Palabras clave: Magnetic Resonance Imaging (MRI) , T2 decay times , Ultra-short Echo Time (UTE) , Zero Echo Time (ZTE) , Spin-locking
Derechos de uso: Reconocimiento (by)
Fuente:
Scientific Reports. (issn: 2045-2322 )
DOI: 10.1038/s41598-023-28640-x
Editorial:
Nature Publishing Group
Versión del editor: https://doi.org/10.1038/s41598-023-28640-x
Código del Proyecto:
info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PID2019-111436RB-C21/ES/IMAGEN FOTOACUSTICA CON NANOPARTICUTLAS CON PROPIEDADES OPTOELECTRONICAS Y MAGNETICAS/
info:eu-repo/grantAgreement/GVA//IDIFEDER%2F2018%2F022//EQUIPOS PARA TECNICAS MIXTAS ELECTROMAGNETICAS-ULTRASONICAS PARA IMAGEN MEDICA/
info:eu-repo/grantAgreement/GVA//IDIFEDER%2F2021%2F004/
info:eu-repo/grantAgreement/AVI//INNTA3%2F2021%2F17/
Agradecimientos:
This work was supported by the Ministerio de Ciencia e Innovacion of Spain through research grant PID2019-111436RB-C21. Action co-financed by the European Union through the Programa Operativo del Fondo Europeo de Desarrollo ...[+]
Tipo: Artículo

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem