Ficheros en el ítem

dc.contributor.advisor Vilariño Feltrer, Guillermo es_ES
dc.contributor.advisor Yusefi, Masoud es_ES
dc.contributor.advisor Sommer, Gerhard es_ES
dc.contributor.author Ibáñez Gómez, Elena es_ES
dc.date.accessioned 2024-11-06T10:34:09Z
dc.date.available 2024-11-06T10:34:09Z
dc.date.created 2024-09-20
dc.date.issued 2024-11-06 es_ES
dc.identifier.uri http://hdl.handle.net/10251/211349
dc.description.abstract [ES] Las enfermedades aórticas letales, como los aneurismas y las disecciones, que involucran anomalías en las paredes de la aorta, son tratadas mediante reparación endovascular con la inserción de una endoprótesis (stent). Este dispositivo de malla ayuda a mantener el vaso sanguíneo abierto, pero su rigidez puede causar complicaciones como fugas de sangre, trombosis, daño local o fallo del injerto. Este estudio tiene como objetivo cuantificar el comportamiento de un injerto vascular sintético bajo diferentes rangos de cargas fisiológicas de la aorta ascendente, con el propósito de determinar la complacencia del vaso a través de diversas mediciones de volumen y presión. Para ello, se realizarán pruebas que incluyen tensión uniaxial, torsión e inflación. El objetivo es mejorar los resultados del tratamiento y reducir los riesgos asociados a este procedimiento. es_ES
dc.description.abstract [EN] Advancements in the treatment of vascular diseases require a deep understanding of the biomechanical properties of vascular grafts. This thesis focuses on evaluating the mechanical behavior of a synthetic Dacron vascular graft, with an emphasis on the ascending aorta, which is the most important artery in the cardiovascular system and is responsible for managing the high pressure blood flow coming directly from the heart. Despite progress in graft technology, achieving accurate compliance with the mechanical behaviour of the aorta remains a challenge. The main objective is to evaluate the compliance and deformation responses of the graft under various physiological conditions: normotension, hypertension, and hypotension. A testing protocol was developed, involving controlled axial forces, inflation pressures, and torsion to simulate different blood pressure conditions. The compliance of the graft was measured through extension-inflation-torsion tests and some calculations. The results revealed that the graft compliance varied with pressure conditions, displaying nonlinear stress-strain behavior typical of biological tissue properties. Specifically, under hypertensive conditions, the graft exhibited increased stiffness and reduced compliance, mirroring the natural response of blood vessels to high pressure. These conclusions emphasize the importance of further research to optimize graft performance, particularly under hypertensive conditions, and to explore customized solutions for different aortic segments. es_ES
dc.format.extent 56 es_ES
dc.language Inglés es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Complianza es_ES
dc.subject Aorta ascendente es_ES
dc.subject Injerto vascular es_ES
dc.subject Extensión-inflación-torsión es_ES
dc.subject Rigidez aórtica es_ES
dc.subject Pared aórtica es_ES
dc.subject Condiciones fisiológicas es_ES
dc.subject Compliance es_ES
dc.subject Ascending aorta es_ES
dc.subject Vascular graft es_ES
dc.subject Extension-inflation-torsion tests es_ES
dc.subject Aortic stiffness es_ES
dc.subject Aortic wall es_ES
dc.subject Physiological conditions es_ES
dc.subject.classification MAQUINAS Y MOTORES TERMICOS es_ES
dc.subject.other Grado en Ingeniería Biomédica-Grau en Enginyeria Biomèdica es_ES
dc.title Quantification of vascular graft compliance under physiological loading conditions of the ascending aorta es_ES
dc.title.alternative Cuantificación de la complianza de un injerto vascular bajo condiciones de carga fisiológica de la aorta ascendente es_ES
dc.title.alternative Quantificació de la compliança d'un empelt vascular sota condicions de càrrega fisiològica de l'aorta ascendent es_ES
dc.type Proyecto/Trabajo fin de carrera/grado es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Termodinámica Aplicada - Departament de Termodinàmica Aplicada es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Ibáñez Gómez, E. (2024). Quantification of vascular graft compliance under physiological loading conditions of the ascending aorta. Universitat Politècnica de València. http://hdl.handle.net/10251/211349 es_ES
dc.description.accrualMethod TFGM es_ES