Mostrar el registro sencillo del ítem
dc.contributor.author | Vlascici, Dana | es_ES |
dc.contributor.author | Fagadar-Cosma, Eugenia | es_ES |
dc.contributor.author | Popa, Iuliana | es_ES |
dc.contributor.author | Chiriac, Vlad | es_ES |
dc.contributor.author | Gil Agustí, María Teresa | es_ES |
dc.date.accessioned | 2013-05-14T09:13:07Z | |
dc.date.available | 2013-05-14T09:13:07Z | |
dc.date.issued | 2012 | |
dc.identifier.issn | 1424-8220 | |
dc.identifier.uri | http://hdl.handle.net/10251/28815 | |
dc.description.abstract | [EN] Three A3B porphyrins with mixed carboxy-, phenoxy-, pyridyl- and dimethoxysubstituent functionalization on the meso-phenyl groups were obtained by multicomponent synthesis, fully characterized and used as ionophores for preparing PVC-based membrane sensors selective to iron(III). The membranes have an ionophore:PVC:plasticizer composition ratio of 1:33:66. Sodium tetraphenylborate was used as additive (20 mol% relative to ionophore). The performance characteristics (linear concentration range, slope and selectivity) of the sensors were investigated. The best results were obtained for the membrane based on 5-(4-carboxyphenyl)-10,15,20-tris(4-phenoxyphenyl)-porphyrin plasticized with bis(2-ethylhexyl)sebacate, in a linear range from 1 ¿ 10¿7¿1 ¿ 10¿1 M with a slope of 21.6 mV/decade. The electrode showed high selectivity with respect to alkaline and heavy metal ions and a response time of 20 s. The influence of pH on the sensor response was studied. The sensor was used for a period of six weeks and the utility has been tested for the quantitative determination of Fe(III) in recovered solutions from spent lithium ion batteries and for the quantitative determination of Fe(III) in tap water samples. | es_ES |
dc.description.sponsorship | The research leading to these results has received funding from the European Community’s Seventh Framework Programme (FP7/2007-2013) under grant agreement n° 266090 (SOMABAT), Romanian PNCDI2 Program-Module III-EU 128/2011 and is a result of collaboration between the coauthors within the project POSDRU/21/1.5/G/38347. | |
dc.language | Inglés | es_ES |
dc.publisher | MDPI | es_ES |
dc.relation.ispartof | Sensors | es_ES |
dc.rights | Reconocimiento (by) | es_ES |
dc.subject | porphyrins | es_ES |
dc.subject | ion-selective electrode | es_ES |
dc.subject | potentiometry | es_ES |
dc.subject | lithium ion batteries | es_ES |
dc.subject | iron(III) | es_ES |
dc.subject | PVC membrane | es_ES |
dc.title | A novel sensor for monitoring of iron (III) ions based on porphyrins | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.3390/s120608193 | |
dc.relation.projectID | info:eu-repo/grantAgreement/EC/FP7/226090/EU/ | en_EN |
dc.relation.projectID | info:eu-repo/grantAgreement/UEFISCDI/PNCDI II/128%2F2011/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/ESF//POSDRU%2F21%2F1.5%2FG%2F38347/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Ingeniería Energética - Institut d'Enginyeria Energètica | es_ES |
dc.description.bibliographicCitation | Vlascici, D.; Fagadar-Cosma, E.; Popa, I.; Chiriac, V.; Gil Agustí, MT. (2012). A novel sensor for monitoring of iron (III) ions based on porphyrins. Sensors. 12(6):8193-8203. https://doi.org/10.3390/s120608193 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.3390/s120608193 | es_ES |
dc.description.upvformatpinicio | 8193 | es_ES |
dc.description.upvformatpfin | 8203 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 12 | es_ES |
dc.description.issue | 6 | es_ES |
dc.relation.senia | 232118 | |
dc.identifier.pmid | 22969395 | en_EN |
dc.identifier.pmcid | PMC3436024 | en_EN |
dc.contributor.funder | European Commission | |
dc.contributor.funder | European Social Fund | es_ES |
dc.contributor.funder | Executive Agency for Higher Education, Scientific Research, Development and Innovation Funding, Rumanía | es_ES |