Mostrar el registro sencillo del ítem
dc.contributor.author | Climent Terol, Estela | es_ES |
dc.contributor.author | Martínez Mañez, Ramón | es_ES |
dc.contributor.author | Maquieira Catala, Ángel | es_ES |
dc.contributor.author | Sancenón Galarza, Félix | es_ES |
dc.contributor.author | Marcos Martínez, María Dolores | es_ES |
dc.contributor.author | Brun Sánchez, Eva María | es_ES |
dc.contributor.author | Soto Camino, Juan | es_ES |
dc.contributor.author | Amoros del Toro, Pedro | es_ES |
dc.date.accessioned | 2013-06-11T14:11:50Z | |
dc.date.available | 2013-06-11T14:11:50Z | |
dc.date.issued | 2012 | |
dc.identifier.issn | 2191-1363 | |
dc.identifier.uri | http://hdl.handle.net/10251/29641 | |
dc.description.abstract | [EN] The synthesis of capped mesoporous silica nanoparticles (MSN) conjugated with an antibody (AB) as a gatekeeper has been carried out in order to obtain a delivery system able to release an entrapped cargo (dye) in the presence of a target molecule (antigen) to which the conjugated antibody binds selectively. In particular, MSN loaded with rhodamine B and functionalized on the external surface with a suitable derivative of N-(t-butyl)- 3-oxo-(5a,17b)-4-aza-androst-1-ene-17-carboxamide (finasteride) have been prepared (S1). The addition of polyclonal antibodies against finasteride induced capping of the pores due to the interaction with the anchored hapten-like finasteride derivative to give a MSN¿hapten¿AB nanoparticle S1-AB. It was found that the addition of capped material S1-AB to water solutions containing finasteride resulted in displacement of the antibody, pore uncapping and entrapped-dye release. The response of the gated material is highly selective, and only finasteride, among other steroids, was able to induce a significant uncapping process. Compared with finasteride, the finasteride metabolite was able to release 17% of the dye, whereas the exogen steroids testosterone, metenolone and 16-b-hydroxystanozolol only induced very little release of rhodamine B (lower than 10%) from aqueous suspensions containing sensing solid S1-AB. A detection limit as low as 20 ppb was found for the fluorimetric detection of finasteride. In order to evaluate a possible application of the material for label-free detection of finasteride, the capped material was isolated and stored to give final sensing solid S1-AB-i. It was found to display a similar behavior towards finasteride as to that shown by freshly prepared S1-AB; even after a period of two months, no significant loss of selectivity or sensitivity was noted. Moreover, to study the application for the detection of finasteride in biological samples, this ¿aged¿ material, S1-AB-i, was tested using commercially available blank urine as matrix. Samples containing 70 and 90% blank urine were spiked with a defined amount of finasteride, and the concentration was determined using capped S1-AB-i. Recovery ranges from 94% to 118% were reached. | es_ES |
dc.description.sponsorship | Financial support from the Spanish Government (project MAT2009-14564-C04-01) and the Generalitat Valenciana (Spain) (projects PROMETEO/2009/016 and PROMETEO/2010/008) is gratefully acknowledged. E. C. thanks the Minesterio de Ciencia e Innovacion (MICINN, Spain) for her fellowship. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | Wiley Open Access | es_ES |
dc.relation.ispartof | ChemistryOpen | es_ES |
dc.rights | Reconocimiento - No comercial (by-nc) | es_ES |
dc.subject.classification | INGENIERIA DE LA CONSTRUCCION | es_ES |
dc.subject.classification | QUIMICA ANALITICA | es_ES |
dc.subject.classification | QUIMICA INORGANICA | es_ES |
dc.subject.classification | QUIMICA ORGANICA | es_ES |
dc.title | Antibody-Capped Mesoporous Nanoscopic Materials:Design of a Probe for the Selective Chromo-FluorogenicDetection of Finasteride | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1002/open.201100008 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//MAT2009-14564-C04-01/ES/Nanomateriales Hibridos Para El Desarrollo De \"Puertas Moleculares\" De Aplicacion En Procesos De Reconocimiento Y Terapeutica Y Para La Deteccion De Explosivos/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//PROMETEO09%2F2009%2F016/ES/Ayuda prometeo 2009 para el grupo de diseño y desarrollo de sensores/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//PROMETEO%2F2010%2F008/ES/AYUDA PARA EL GRUPO SYM-IDM/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Química - Departament de Química | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Reconocimiento Molecular y Desarrollo Tecnológico - Institut de Reconeixement Molecular i Desenvolupament Tecnològic | es_ES |
dc.description.bibliographicCitation | Climent Terol, E.; Martínez Mañez, R.; Maquieira Catala, Á.; Sancenón Galarza, F.; Marcos Martínez, MD.; Brun Sánchez, EM.; Soto Camino, J.... (2012). Antibody-Capped Mesoporous Nanoscopic Materials:Design of a Probe for the Selective Chromo-FluorogenicDetection of Finasteride. ChemistryOpen. 1:251-259. https://doi.org/10.1002/open.201100008 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://onlinelibrary.wiley.com/doi/10.1002/open.201100008/pdf | es_ES |
dc.description.upvformatpinicio | 251 | es_ES |
dc.description.upvformatpfin | 259 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 1 | es_ES |
dc.relation.senia | 232745 | |
dc.identifier.pmid | 24551515 | en_EN |
dc.identifier.pmcid | PMC3922482 | en_EN |
dc.contributor.funder | Generalitat Valenciana | |
dc.contributor.funder | Ministerio de Ciencia e Innovación | es_ES |