Mostrar el registro sencillo del ítem
dc.contributor.author | Burdío, Fernando | es_ES |
dc.contributor.author | Tobajas, Pilar | es_ES |
dc.contributor.author | Quesada-Diez, Rita | es_ES |
dc.contributor.author | Berjano, Enrique | es_ES |
dc.contributor.author | Navarro, Ana | es_ES |
dc.contributor.author | Poves, Ignasi | es_ES |
dc.contributor.author | Grande, Luís | es_ES |
dc.date.accessioned | 2013-06-25T09:32:01Z | |
dc.date.issued | 2011-06 | |
dc.identifier.issn | 0361-803X | |
dc.identifier.uri | http://hdl.handle.net/10251/30076 | |
dc.description.abstract | OBJECTIVE. Our aim was to evaluate the capability of a Cool-tip electrode to create larger coagulation volumes combined with a low-flow (0.1 mL/min) perfusion of hypertonic saline at a distance of 2 mm (hybrid applicator) without reducing either predictability or sphericity of the coagulation zone. MATERIALS AND METHODS. A total of 48 radiofrequency ablations were performed on a total of 12 adult pigs: 24 with the Cool-tip (group 1) and 24 with the hybrid applicator (group 2). Volumes and diameters were assessed both macroscopically and with imaging techniques (ultrasound and MRI). Digital reconstruction techniques were also used. Reproducibility of the coagulations was assessed by means of the coefficient of variation. RESULTS. The macroscopic assessment showed a significantly larger coagulation zone in group 2 than in group 1, both with (19.40 ± 11.38 cm3 vs 9.16 ± 5.62 cm3; p < 0.001) and without (19.54 ± 11.39 cm3 vs 9.21 ± 5.74 cm3; p < 0.001) digital reconstruction. Differences were also significant in the MRI assessment. The minimum transverse diameter was also significantly (p < 0.01) larger in group 2 than group 1: 2.46 ± 0.61 versus 1.86 ± 0.55 cm for macroscopic assessment, 2.33 ± 0.96 versus 1.69 ± 0.53 cm for ultrasound, and 2.41 ± 0.58 versus 1.8 ± 0.52 cm for MRI. The coefficient of variation was similar in both groups. CONCLUSION. The results suggest that low-flow perfusion of hypertonic saline at 2 mm from a Cool-tip electrode could increase coagulation zone volume without reducing predictability. | es_ES |
dc.description.sponsorship | This work received financial support from the Spanish "Plan Nacional de I+D+I del Ministerio de Ciencia e Innovacion" grant number TEC2008-01369/TEC. The translation of this article was funded by the Universidad Politecnica de Valencia, Spain. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | American Roentgen Ray Society (ARRS) | es_ES |
dc.relation.ispartof | American Journal of Roentgenology | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Coagulation volume | es_ES |
dc.subject | Liver | es_ES |
dc.subject | Perfusion electrode | es_ES |
dc.subject | radiofrequency ablation | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.title | Distant infusion of saline may enlarge coagulation volume during radiofrequency ablation of liver tissue using cool-tip electrodes without impairing predictability | es_ES |
dc.type | Artículo | es_ES |
dc.embargo.lift | 10000-01-01 | |
dc.embargo.terms | forever | es_ES |
dc.identifier.doi | 10.2214/AJR.10.5202 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//TEC2008-01369/ES/MODELOS COMPUTACIONALES E INVESTIGACION EXPERIMENTAL EN EL ESTUDIO DE TECNICAS QUIRURGICAS DE CALENTAMIENTO DE TEJIDOS BIOLOGICOS MEDIANTE CORRIENTES DE RADIOFRECUENCIA./ | |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica | es_ES |
dc.description.bibliographicCitation | Burdío, F.; Tobajas, P.; Quesada-Diez, R.; Berjano, E.; Navarro, A.; Poves, I.; Grande, L. (2011). Distant infusion of saline may enlarge coagulation volume during radiofrequency ablation of liver tissue using cool-tip electrodes without impairing predictability. American Journal of Roentgenology. 196(6):837-843. https://doi.org/10.2214/AJR.10.5202 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://www.ajronline.org/doi/pdf/10.2214/AJR.10.5202 | es_ES |
dc.description.upvformatpinicio | 837 | es_ES |
dc.description.upvformatpfin | 843 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 196 | es_ES |
dc.description.issue | 6 | es_ES |
dc.relation.senia | 214125 | |
dc.contributor.funder | Ministerio de Ciencia e Innovación | |
dc.contributor.funder | Universitat Politècnica de València | es_ES |