- -

Calibration of a wide angle stereoscopic system

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Calibration of a wide angle stereoscopic system

Mostrar el registro completo del ítem

Ricolfe Viala, C.; Sánchez Salmerón, AJ.; Martínez Berti, E. (2011). Calibration of a wide angle stereoscopic system. Optics Letters. 36(16):3064-3067. doi:10.1364/OL.36.003064

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/30840

Ficheros en el ítem

Metadatos del ítem

Título: Calibration of a wide angle stereoscopic system
Autor: Ricolfe Viala, Carlos Sánchez Salmerón, Antonio José Martínez Bertí, Enrique
Entidad UPV: Universitat Politècnica de València. Departamento de Ingeniería de Sistemas y Automática - Departament d'Enginyeria de Sistemes i Automàtica
Fecha difusión:
Resumen:
Inaccuracies in the calibration of a stereoscopic system appear with errors in point correspondences between both images and inexact points localization in each image. Errors increase if the stereoscopic system is composed ...[+]
Palabras clave: Epipolar constraints , Fundamental matrix , Geometrical constraints , Lens distortion , Nonlinear minimization , Point correspondence , Point localization , Point location , Stereoscopic systems , Wide angle , Wide-angle lens , Errors , Calibration
Derechos de uso: Reserva de todos los derechos
Fuente:
Optics Letters. (issn: 0146-9592 )
DOI: 10.1364/OL.36.003064
Editorial:
Optical Society of America
Versión del editor: http://dx.doi.org/10.1364/OL.36.003064
Descripción: This paper was published in OPTICS LETTERS and is made available as an electronic reprint with the permission of OSA. The paper can be found at the following URL on the OSA website: http://dx.doi.org/10.1364/OL.36.003064. Systematic or multiple reproduction or distribution to multiple locations via electronic or other means is prohibited and is subject to penalties under law.
Tipo: Artículo

References

Zhang, Z., Ma, H., Guo, T., Zhang, S., & Chen, J. (2011). Simple, flexible calibration of phase calculation-based three-dimensional imaging system. Optics Letters, 36(7), 1257. doi:10.1364/ol.36.001257

Longuet-Higgins, H. C. (1981). A computer algorithm for reconstructing a scene from two projections. Nature, 293(5828), 133-135. doi:10.1038/293133a0

Ricolfe-Viala, C., & Sanchez-Salmeron, A.-J. (2010). Lens distortion models evaluation. Applied Optics, 49(30), 5914. doi:10.1364/ao.49.005914 [+]
Zhang, Z., Ma, H., Guo, T., Zhang, S., & Chen, J. (2011). Simple, flexible calibration of phase calculation-based three-dimensional imaging system. Optics Letters, 36(7), 1257. doi:10.1364/ol.36.001257

Longuet-Higgins, H. C. (1981). A computer algorithm for reconstructing a scene from two projections. Nature, 293(5828), 133-135. doi:10.1038/293133a0

Ricolfe-Viala, C., & Sanchez-Salmeron, A.-J. (2010). Lens distortion models evaluation. Applied Optics, 49(30), 5914. doi:10.1364/ao.49.005914

Armangué, X., & Salvi, J. (2003). Overall view regarding fundamental matrix estimation. Image and Vision Computing, 21(2), 205-220. doi:10.1016/s0262-8856(02)00154-3

Devernay, F., & Faugeras, O. (2001). Straight lines have to be straight. Machine Vision and Applications, 13(1), 14-24. doi:10.1007/pl00013269

[-]

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem