Mostrar el registro sencillo del ítem
dc.contributor.author | Ricolfe Viala, Carlos | es_ES |
dc.contributor.author | Sánchez Salmerón, Antonio José | es_ES |
dc.date.accessioned | 2013-07-10T09:11:29Z | |
dc.date.available | 2013-07-10T09:11:29Z | |
dc.date.issued | 2011 | |
dc.identifier.issn | 1094-4087 | |
dc.identifier.uri | http://hdl.handle.net/10251/30973 | |
dc.description | This paper was published in OPTICS EXPRESS and is made available as an electronic reprint with the permission of OSA. The paper can be found at the following URL on the OSA website: http://dx.doi.org/10.1364/OE.19.010769. Systematic or multiple reproduction or distribution to multiple locations via electronic or other means is prohibited and is subject to penalties under law | es_ES |
dc.description.abstract | Different methods based on photogrammetry or self-calibration exist to calibrate intrinsic and extrinsic camera parameters and also for data pre- and post-processing. From a practical viewpoint, it is quite difficult to decide which calibration method gives accurate results and even whether any data processing is necessary. This paper proposes a set of optimal conditions to resolve the calibration process accurately. The calibration method uses several images of a 2D pattern. Optimal conditions define the number of points and the number of images to resolve the calibration accurately, as well as positions and orientations from where images should be taken. | es_ES |
dc.description.sponsorship | This work was partially funded by the Universidad Politecnica de Valencia research funds (PAID 2010-2431 and PAID 10017), Generalitat Valenciana (GV/2011/057) and by Spanish government and the European Community under the project DPI2010-20814-C02-02 (FEDER-CICYT) and DPI2010-20286 (CICYT). | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | Optical Society of America | es_ES |
dc.relation.ispartof | Optics Express | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | 2D patterns | es_ES |
dc.subject | Calibration method | es_ES |
dc.subject | Calibration process | es_ES |
dc.subject | Camera calibration | es_ES |
dc.subject | Intrinsic and extrinsic camera parameters | es_ES |
dc.subject | Optimal conditions | es_ES |
dc.subject | Post processing | es_ES |
dc.subject | Self calibration | es_ES |
dc.subject | Cameras | es_ES |
dc.subject | Data handling | es_ES |
dc.subject | Optimization | es_ES |
dc.subject | Calibration | es_ES |
dc.subject.classification | INGENIERIA DE SISTEMAS Y AUTOMATICA | es_ES |
dc.title | Camera calibration under optimal conditions | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1364/OE.19.010769 | |
dc.relation.projectID | info:eu-repo/grantAgreement/UPV//PAID-2010-2431/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/UPV//PAID-10-017/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//GV%2F2011%2F057/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//DPI2010-20814-C02-02/ES/IDENTIFICACION DE PARAMETROS DINAMICOS EN VEHICULOS LIGEROS Y ROBOTS MOVILES. APLICACION AL CONTROL Y LA NAVEGACION AUTOMATICA/ / | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//DPI2010-20286/ES/INSPECCION Y MANIPULACION DE PRODUCTOS ALIMENTICIOS/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería de Sistemas y Automática - Departament d'Enginyeria de Sistemes i Automàtica | es_ES |
dc.description.bibliographicCitation | Ricolfe Viala, C.; Sánchez Salmerón, AJ. (2011). Camera calibration under optimal conditions. Optics Express. 19(11):10770-10776. https://doi.org/10.1364/OE.19.010769 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1364/OE.19.010769 | es_ES |
dc.description.upvformatpinicio | 10770 | es_ES |
dc.description.upvformatpfin | 10776 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 19 | es_ES |
dc.description.issue | 11 | es_ES |
dc.relation.senia | 208968 | |
dc.contributor.funder | Ministerio de Ciencia e Innovación | es_ES |
dc.contributor.funder | Generalitat Valenciana | es_ES |
dc.contributor.funder | Universitat Politècnica de València | es_ES |
dc.description.references | Lin, P. D., & Sung, C. K. (2007). Comparing two new camera calibration methods with traditional pinhole calibrations. Optics Express, 15(6), 3012. doi:10.1364/oe.15.003012 | es_ES |
dc.description.references | Bauer, M., Grießbach, D., Hermerschmidt, A., Krüger, S., Scheele, M., & Schischmanow, A. (2008). Geometrical camera calibration with diffractive optical elements. Optics Express, 16(25), 20241. doi:10.1364/oe.16.020241 | es_ES |
dc.description.references | Choi, K. S., Lam, E. Y., & Wong, K. K. Y. (2006). Automatic source camera identification using the intrinsic lens radial distortion. Optics Express, 14(24), 11551. doi:10.1364/oe.14.011551 | es_ES |
dc.description.references | Weng, J., Cohen, P., & Herniou, M. (1992). Camera calibration with distortion models and accuracy evaluation. IEEE Transactions on Pattern Analysis and Machine Intelligence, 14(10), 965-980. doi:10.1109/34.159901 | es_ES |
dc.description.references | Kopparapu, S., & Corke, P. (2001). The Effect of Noise on Camera Calibration Parameters. Graphical Models, 63(5), 277-303. doi:10.1006/gmod.2001.0551 | es_ES |
dc.description.references | Zhang, Z. (2000). A flexible new technique for camera calibration. IEEE Transactions on Pattern Analysis and Machine Intelligence, 22(11), 1330-1334. doi:10.1109/34.888718 | es_ES |
dc.description.references | Hartley, R. I. (1997). In defense of the eight-point algorithm. IEEE Transactions on Pattern Analysis and Machine Intelligence, 19(6), 580-593. doi:10.1109/34.601246 | es_ES |
dc.description.references | Salvi, J., Armangué, X., & Batlle, J. (2002). A comparative review of camera calibrating methods with accuracy evaluation. Pattern Recognition, 35(7), 1617-1635. doi:10.1016/s0031-3203(01)00126-1 | es_ES |
dc.description.references | Sun, W., & Cooperstock, J. R. (2006). An empirical evaluation of factors influencing camera calibration accuracy using three publicly available techniques. Machine Vision and Applications, 17(1), 51-67. doi:10.1007/s00138-006-0014-6 | es_ES |