Real-Time Continuous Glucose Monitoring in an Intensive Care Unit: Better Accuracy in Patients with Septic Shock

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Real-Time Continuous Glucose Monitoring in an Intensive Care Unit: Better Accuracy in Patients with Septic Shock

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Lorencio, Carol es_ES
dc.contributor.author Leal, Yenny es_ES
dc.contributor.author Bonet Alonso, Alfonso es_ES
dc.contributor.author Bondía Company, Jorge es_ES
dc.contributor.author Palerm, César C. es_ES
dc.contributor.author Tache, Abdo es_ES
dc.contributor.author Sirvent, Josep Maria es_ES
dc.contributor.author Vehi, Josep es_ES
dc.date.accessioned 2013-07-16T12:11:28Z
dc.date.available 2013-07-16T12:11:28Z
dc.date.issued 2012
dc.identifier.issn 1520-9156
dc.identifier.uri http://hdl.handle.net/10251/31155
dc.description This is a copy of an article published in the Diabetes Technology and Therapeutics © 2012 [copyright Mary Ann Liebert, Inc.]; Diabetes Technology and Therapeutics is available online at: http://online.liebertpub.com. es_ES
dc.description.abstract [EN] Objective: This study assessed the accuracy of real-time continuous glucose monitoring system (RTCGMS) devices in an intensive care unit (ICU) to determine whether the septic status of the patient has any in¿uence on the accuracy of the RTCGMS. Subjects and Methods: In total, 41 patients on insulin therapy were included. Patients were monitored for 72 h using RTCGMS. Arterial blood glucose (ABG) samples were obtained following the protocol established in the ICU. The results were evaluated using paired values (excluding those used for calibration) with the performance assessed using numerical accuracy. Nonparametric tests were used to determine statistically signi¿cant differences in accuracy. Results: In total, 956 ABG/RTCGMS pairs were analyzed. The overall median relative absolute difference (RAD) was 13.5%, and the International Organization for Standardization (ISO) criteria were 68.1%. The median RADs reported for patients with septic shock, with sepsis, and without sepsis were 11.2%, 14.3%, and 16.3%, respectively (P<0.05). Measurements meeting the ISO criteria were 74.5%, 65.6%, and 63.7% for patients with septic shock, with sepsis, and without sepsis, respectively (P<0.05). Conclusions: The results showed that the septic status of patients in¿uenced the accuracy of the RTCGMS in the ICU. Accuracy was signi¿cantly better in patients with septic shock in comparison with the other patient cohorts. es_ES
dc.description.sponsorship This work was supported by the Spanish Ministry of Science and Innovation through grants DPI2007-66728-C02 and DPI-2010-20764-C02, the European Union through FEDER funds, and the Autonomous Government of Catalonia through 2009 SGR 523. Y.L. is grateful for the BR Grants of the University of Girona. The authors thank the Ph.D. candidate student Xavier Berjaga, who helped with the statistical analysis in this work. The authors thank the nursing staff of the ICU of Doctor Josep Trueta Hospital for their work; without them, this study could not have been conducted. Medtronic, Inc. provided some of the devices used in this study. en_EN
dc.language Inglés es_ES
dc.publisher Mary Ann Liebert es_ES
dc.relation.ispartof Diabetes Technology & Therapeutics es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject CRITICALLY-ILL PATIENTS es_ES
dc.subject INSULIN THERAPY es_ES
dc.subject STRESS HYPERGLYCEMIA es_ES
dc.subject ORGAN FAILURE es_ES
dc.subject SEVERE SEPSIS es_ES
dc.subject GUIDELINES es_ES
dc.subject MANAGEMENT es_ES
dc.subject CHILDREN es_ES
dc.subject ANALYZER es_ES
dc.subject PROTOCOL es_ES
dc.subject.classification INGENIERIA DE SISTEMAS Y AUTOMATICA es_ES
dc.title Real-Time Continuous Glucose Monitoring in an Intensive Care Unit: Better Accuracy in Patients with Septic Shock es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1089/dia.2012.0008
dc.relation.projectID info:eu-repo/grantAgreement/Generalitat de Catalunya//2009 SGR 00523/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MEC//DPI2007-66728-C02-01/ES/CONTROL DE GLUCEMIA EN LAZO CERRADO EN PACIENTES CON DIABETES MELLITUS 1 Y PACIENTES CRITICOS/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MEC//DPI2007-66728-C02-02/ES/CONTROL DE GLUCEMIA EN LAZO CERRADO EN PACIENTES CON DIABETES MELLITUS 1 Y PACIENTES CRITICOS/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//DPI2010-20764-C02-01/ES/NUEVAS ESTRATEGIAS DE CONTROL GLUCEMICO POSTPRANDIAL MEDIANTE TERAPIA CON BOMBA DE INSULINA EN DIABETES TIPO 1/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//DPI2010-20764-C02-02/ES/NUEVAS ESTRATEGIAS DE CONTROL GLUCEMICO POSTPRANDIAL MEDIANTE TERAPIA CON BOMBA DE INSULINA EN DIABETES TIPO 1/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería de Sistemas y Automática - Departament d'Enginyeria de Sistemes i Automàtica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto Universitario de Automática e Informática Industrial - Institut Universitari d'Automàtica i Informàtica Industrial es_ES
dc.description.bibliographicCitation Lorencio, C.; Leal, Y.; Bonet Alonso, A.; Bondía Company, J.; Palerm, CC.; Tache, A.; Sirvent, JM.... (2012). Real-Time Continuous Glucose Monitoring in an Intensive Care Unit: Better Accuracy in Patients with Septic Shock. Diabetes Technology & Therapeutics. 14(7):568-575. https://doi.org/10.1089/dia.2012.0008 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1089/dia.2012.0008 es_ES
dc.description.upvformatpinicio 568 es_ES
dc.description.upvformatpfin 575 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 14 es_ES
dc.description.issue 7 es_ES
dc.relation.senia 240850
dc.identifier.eissn 1557-8593
dc.identifier.pmid 22512288 en_EN
dc.identifier.pmcid PMC3389383 en_EN
dc.contributor.funder Ministerio de Ciencia e Innovación es_ES
dc.contributor.funder Ministerio de Educación y Ciencia es_ES
dc.contributor.funder Generalitat de Catalunya es_ES
dc.contributor.funder European Regional Development Fund es_ES
dc.contributor.funder Universitat de Girona es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem