Accuracy combining different brands of implants and abutments

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Accuracy combining different brands of implants and abutments

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Solá-Ruiz, María-Fernanda es_ES
dc.contributor.author Selva-Otaolaurruchi, Eduardo es_ES
dc.contributor.author Senent-Vicente, Gisela es_ES
dc.contributor.author González-de-Cossio, Inés es_ES
dc.contributor.author Amigó Borrás, Vicente
dc.date.accessioned 2013-10-01T10:33:48Z
dc.date.issued 2013-03
dc.identifier.issn 1698-4447
dc.identifier.uri http://hdl.handle.net/10251/32501
dc.description.abstract Objective: To evaluate the vertical misfit between different brands of dental implants and prosthetic abutments, with or without mechanical torque, and to study their possible combination. Study design: Five different brands of implant were used in the study: Biofit (Castemaggiore, Italy), Bioner S.A. (Barcelona, Spain), 3i Biomet (Palm Beach, U.S.A.), BTI (Alava, Spain) and Nobel Biocare (Göteborg, Sweden), with standard 4.1 mm heads and external hexagons, and their respective machined prosthetic abutments. The implant-toabutment fit/misfit was evaluated at four points (vestibular, lingual/palatine, mesial and distal) between implants and abutments of the same brand and different brands, with or without mechanical torque, using SEM micrographs at 5000X. Image analysis was performed using NIS-Elements software (Nikon Instruments Europe B.V.). Results: Before applying torque, vertical misfit (microgaps) of the different combinations tested varied between 1.6 and 5.4 microns and after applying torque, between 0.9 and 5.9 microns, an overall average of 3.46±2.96 microns. For manual assembly without the use of mechanical torque, the best results were obtained with the combination of the 3i implant and the BTI abutment. The Nobel implant and Nobel abutment, 3i-3i and BTI-BTI and the combination of 3i implant with BTI or Nobel abutment provided the best vertical fit when mechanical torque was applied. Conclusions: The vertical fits obtained were within the limits considered clinically acceptable. The application of mechanical torque improved outcomes. There is compatibility between implants and abutments of different brand and so their combination is a clinical possibility. es_ES
dc.format.extent 5 es_ES
dc.language Inglés es_ES
dc.publisher Medicina Oral, S. L. es_ES
dc.relation.ispartof Medicina Oral, Patología Oral y Cirugía Bucal es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Implant es_ES
dc.subject Dental es_ES
dc.subject Vertical fit es_ES
dc.subject Prosthetic abutment es_ES
dc.subject Combination es_ES
dc.subject.classification CIENCIA DE LOS MATERIALES E INGENIERIA METALURGICA es_ES
dc.title Accuracy combining different brands of implants and abutments es_ES
dc.type Artículo es_ES
dc.embargo.lift 10000-01-01
dc.embargo.terms forever es_ES
dc.identifier.doi 10.4317/medoral.18137
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Mecánica y de Materiales - Departament d'Enginyeria Mecànica i de Materials es_ES
dc.description.bibliographicCitation Solá-Ruiz, M.; Selva-Otaolaurruchi, E.; Senent-Vicente, G.; González-De-Cossio, I.; Amigó Borrás, V. (2013). Accuracy combining different brands of implants and abutments. Medicina Oral, Patología Oral y Cirugía Bucal. 18:332-336. doi:10.4317/medoral.18137 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/doi:10.4317/medoral.18137 es_ES
dc.description.upvformatpinicio 332 es_ES
dc.description.upvformatpfin 336 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 18 es_ES
dc.relation.senia 236918
dc.identifier.pmid 23229250 es_ES
dc.identifier.pmcid PMC3613888 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem