Influence of total solids concentration on membrane permeability in a submerged hollow-fibre anaerobic membrane bioreactor

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Influence of total solids concentration on membrane permeability in a submerged hollow-fibre anaerobic membrane bioreactor

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Robles Martínez, Ángel es_ES
dc.contributor.author Durán Pinzón, Freddy es_ES
dc.contributor.author Ruano García, María Victoria es_ES
dc.contributor.author Ribes Bertomeu, Jose es_ES
dc.contributor.author Ferrer Polo, José es_ES
dc.date.accessioned 2013-10-23T09:15:45Z
dc.date.issued 2012
dc.identifier.issn 0273-1223
dc.identifier.uri http://hdl.handle.net/10251/33015
dc.description.abstract The main aim of this work was to study the influence of the mixed liquor total solids (MLTS) concentration on membrane permeability (K 20) in a submerged anaerobic membrane bioreactor (SAnMBR) pilot plant, which is equipped with industrial hollow-fibre membranes and treats urban wastewater. This pilot plant was operated at 33°C and 70 days of SRT. Two different transmembrane fluxes (13.3 and 10 LMH) were tested with a gas sparging intensity of 0.23 Nm 3 m -2 h -1 (measured as Specific Gas Demand referred to membrane area). A linear dependence of K 20 on MLTS concentration was observed within a range of MLTS concentration from 13 to 32 g L -1 and J 20 of 10 LMH. K 20 was maintained at sustainable values (about 100 LMH bar -1) even at high MLTS concentrations (up to 20 g L -1). In addition, several short-tests were carried out when the membranes were operated at high MLTS concentrations in order to assess the effect of the physical cleaning strategies (relaxation and back-flush) on membrane performance. It was observed that, with the applied gas sparging intensity, the duration of the relaxation stage did not critically affect the membrane performance. On the other hand, the required back-flush frequency was considerably affected by the MLTS concentration. © IWA Publishing 2012. es_ES
dc.description.sponsorship This research work has been supported by the Spanish Research Foundation (CICYT Projects CTM2008-06809-C02-01 and CTM2008-06809-C02-02, and MICINN FPI grant BES-2009-023712) and Generalitat Valenciana (Projects GVA-ACOMP2010/130 and GVA-ACOMP2011/182), which are gratefully acknowledged. en_EN
dc.format.extent 8 es_ES
dc.language Inglés es_ES
dc.publisher IWA Publishing es_ES
dc.relation.ispartof Water Science and Technology es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Fouling rate es_ES
dc.subject Industrial membranes es_ES
dc.subject Mixed liquor total solids concentration es_ES
dc.subject Permeability es_ES
dc.subject Submerged anaerobic membrane bioreactor es_ES
dc.subject.classification INGENIERIA HIDRAULICA es_ES
dc.subject.classification TECNOLOGIA DEL MEDIO AMBIENTE es_ES
dc.title Influence of total solids concentration on membrane permeability in a submerged hollow-fibre anaerobic membrane bioreactor es_ES
dc.type Artículo es_ES
dc.embargo.lift 10000-01-01
dc.embargo.terms forever es_ES
dc.identifier.doi 10.2166/wst.2012.196
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//CTM2008-06809-C02-02/ES/MODELACION DE LA APLICACION DE LA TECNOLOGIA DE MEMBRANAS PARA LA VALORIZACION ENERGETICA DE LA MATERIA ORGANICA DEL AGUA RESIDUAL Y LA MINIMIZACION DE LOS FANGOS PRODUCIDOS. DESARROLLO DE LOS ALGORIT/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//ACOMP%2F2011%2F182/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//ACOMP%2F2010%2F130/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//CTM2008-06809-C02-01/ES/ESTUDIO EN PLANTA PILOTO DE LA APLICACION DE LA TECNOLOGIA DE MEMBRANAS PARA LA VALORIZACION ENERGETICA DE LA MATERIA ORGANICA DEL AGUA RESIDUAL Y LA MINIMIZACION DE LOS FANGOS PRODUCIDOS. EVALUACION/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//BES-2009-023712/ES/BES-2009-023712/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Hidráulica y Medio Ambiente - Departament d'Enginyeria Hidràulica i Medi Ambient es_ES
dc.description.bibliographicCitation Robles Martínez, Á.; Durán Pinzón, F.; Ruano García, MV.; Ribes Bertomeu, J.; Ferrer Polo, J. (2012). Influence of total solids concentration on membrane permeability in a submerged hollow-fibre anaerobic membrane bioreactor. Water Science and Technology. 66(2):377-384. https://doi.org/10.2166/wst.2012.196 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://www.iwaponline.com/wst/06602/wst066020377.htm es_ES
dc.description.upvformatpinicio 377 es_ES
dc.description.upvformatpfin 384 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 66 es_ES
dc.description.issue 2 es_ES
dc.relation.senia 230122
dc.contributor.funder Ministerio de Ciencia e Innovación es_ES
dc.contributor.funder Generalitat Valenciana es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem