- -

Detección automática de la función de entrada arterial mediante análisis de componentes independientes en estudios de perfusión cerebral por resonancia magnética

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Detección automática de la función de entrada arterial mediante análisis de componentes independientes en estudios de perfusión cerebral por resonancia magnética

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Moratal Pérez, David es_ES
dc.contributor.advisor Arana Fernández, Estanislao es_ES
dc.contributor.author Narváez Pérez, Mario Alberto es_ES
dc.date.accessioned 2014-03-04T12:37:36Z
dc.date.available 2014-03-04T12:37:36Z
dc.date.created 2013-09-26
dc.date.issued 2014-03-04
dc.identifier.uri http://hdl.handle.net/10251/36144
dc.description.abstract [ES] La Función de Entrada Arterial es una variable fundamental para el Modelo Compartimental Estándar que describe la relación de la intensidad en un píxel de un tejido con las componentes intra y extra vasculares que forman parte del tejido. La obtención de ésta función permite el cálculo de parámetros relacionados con el flujo de sangre en el tejido que son usados como marcadores subrogados de diferentes funciones tisulares. Al correlacionar las variaciones de éstos parámetros con otras pruebas clínicas se puede determinar el estado de salud del órgano en concreto. Sin embargo, la práctica clínica actual se basa en la selección manual del píxel de una arteria y su evaluación visual, por lo que el método es altamente susceptible a la habilidad y experiencia del radiólogo y al ser un método cualitativo se corre el riesgo de no utilizar toda la información contenida en las curvas de contraste. El Análisis de Componentes Independientes (ICA, por sus siglas en inglés) es un método de separación de fuentes no observables a partir de una serie de muestras que se asume son la combinación lineal de las componentes originales. El método de separación se realiza sin información previa de las fuentes o del proceso de mezcla de las mismas. El objetivo final de ICA es obtener las componentes fundamentales que forman un conjunto de datos, de tal forma que la independencia entre las componentes sea máxima. El objetivo de este Trabajo de Fin de Máster es el desarrollo una herramienta-software que permita la detección automática de la Función de Entrada Arterial mediante el Análisis de Componentes Independientes de imágenes de perfusión cerebral adquiridas mediante resonancia magnética. es_ES
dc.description.abstract [EN] The Arterial Input Function is a fundamental variable for the Standard Compartimental Model which describes the relationship between tissue pixel intensity with its intra and extra vascular components. The attainment of this function allows the computation of tissue blood flow related parameters which are used as subrogated marker of different tissue functions, by correlating variations on this parameters with other clinic test it is possible to determine the organ health status. However, current clinical practice is based on the manual selection of an artery¿s pixel and its visual evaluation; therefore the method is highly susceptible to the radiologist skill and expertise and since it¿s a qualitative method there is a risk of not using all the information contained in the contrast curves. Independent Component Analysis (ICA) is a method for separation of not observable sources from a series of samples which are assumed to be the lineal combination of its original components. The separation method is performed without previous information of the sources or their mixing process. The final goal of ICA is to obtain the fundamental components that form a dataset, in a way that the independence among the components is maximum. The goal of this Master Final Project is the development of a software tool that would allow the automatic detection of the Arterial Input Function by means of the Independent Component Analysis of cerebral perfusion images adquired by magnetic resonance. es_ES
dc.format.extent 72 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Separación ciega de fuentes es_ES
dc.subject Análisis de componentes idependientes es_ES
dc.subject Función de entrada arterial es_ES
dc.subject Estudios de perfusión es_ES
dc.subject Blind source separation es_ES
dc.subject Independent component analysis es_ES
dc.subject Arterial input funcion es_ES
dc.subject Perfusion studies es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.subject.other Máster Universitario en Ingeniería Biomédica-Màster Universitari en Enginyeria Biomèdica es_ES
dc.title Detección automática de la función de entrada arterial mediante análisis de componentes independientes en estudios de perfusión cerebral por resonancia magnética es_ES
dc.type Tesis de máster es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Servicio de Alumnado - Servei d'Alumnat es_ES
dc.description.bibliographicCitation Narváez Pérez, MA. (2013). Detección automática de la función de entrada arterial mediante análisis de componentes independientes en estudios de perfusión cerebral por resonancia magnética. http://hdl.handle.net/10251/36144 es_ES
dc.description.accrualMethod Archivo delegado es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem