Mostrar el registro sencillo del ítem
dc.contributor.author | Moliner Martínez, Laura | es_ES |
dc.contributor.author | Correcher, Carlos | es_ES |
dc.contributor.author | González Martínez, Antonio Javier | es_ES |
dc.contributor.author | Conde Castellanos, Pablo Eloy | es_ES |
dc.contributor.author | Hernández Hernández, Liczandro | es_ES |
dc.contributor.author | Orero Palomares, Abel | es_ES |
dc.contributor.author | Rodríguez Álvarez, María José | es_ES |
dc.contributor.author | Sánchez Martínez, Filomeno | es_ES |
dc.contributor.author | Soriano Asensi, Antonio | es_ES |
dc.contributor.author | Vidal San Sebastián, Luis Fernando | es_ES |
dc.contributor.author | Benlloch Baviera, Jose María | |
dc.date.accessioned | 2014-03-06T10:36:22Z | |
dc.date.issued | 2013-02-21 | |
dc.identifier.issn | 0168-9002 | |
dc.identifier.uri | http://hdl.handle.net/10251/36224 | |
dc.description.abstract | In this work we present an innovative algorithm for the reconstruction of PET images based on the List-Mode (LM) technique which improves their spatial resolution compared to results obtained with current MLEM algorithms. This study appears as a part of a large project with the aim of improving diagnosis in early Alzheimer disease stages by means of a newly developed hybrid PET-MR insert. At the present, Alzheimer is the most relevant neurodegenerative disease and the best way to apply an effective treatment is its early diagnosis. The PET device will consist of several monolithic LYSO crystals coupled to SiPM detectors. Monolithic crystals can reduce scanner costs with the advantage to enable implementation of very small virtual pixels in their geometry. This is especially useful for LM reconstruction algorithms, since they do not need a pre-calculated system matrix. We have developed an LM algorithm which has been initially tested with a large aperture (186 mm) breast PET system. Such an algorithm instead of using the common lines of response, incorporates a novel calculation of tubes of response. The new approach improves the volumetric spatial resolution about a factor 2 at the border of the field of view when compared with traditionally used MLEM algorithm. Moreover, it has also shown to decrease the image noise, thus increasing the image quality. © 2012 Elsevier B.V. All rights reserved. | es_ES |
dc.description.sponsorship | This work was supported by the Centre for Industrial Technological Development co-funded by FEDER through the Technology Fund (DREAM Project, IDI-20110718), by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I+D+I) under Grant. No. FIS2010-21216-CO2-01TEO 2008/114. | en_EN |
dc.format.extent | 4 | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Image reconstruction | es_ES |
dc.subject | LM reconstruction | es_ES |
dc.subject | Monolithic scintillators | es_ES |
dc.subject | PET | es_ES |
dc.subject.classification | MATEMATICA APLICADA | es_ES |
dc.title | Implementation and analysis of list mode algorithm using tubes of response on a dedicated brain and breast PET | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.nima.2012.08.029 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//IDI-20110718/ES/INVESTIGACIÓN EN DETECCIÓN PARA APLICACIONES DE SALUD MENTAL (1%2F3)/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//FIS2010-21216-C02-01/ES/DESARROLLO DEL DETECTOR PET%2FRM PARA DIAGNOSTICO DE ENFERMEDADES NEURODEGENERATIVAS./ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/Generalitat Valenciana//PROMETEO08%2F2008%2F114/ES/Desarrollo de tecnología PET%2FRM para estudio cerebro en humanos/ / | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Matemática Aplicada - Departament de Matemàtica Aplicada | es_ES |
dc.description.bibliographicCitation | Moliner Martínez, L.; Correcher, C.; González Martínez, AJ.; Conde Castellanos, PE.; Hernández Hernández, L.; Orero Palomares, A.; Rodríguez Álvarez, MJ.... (2013). Implementation and analysis of list mode algorithm using tubes of response on a dedicated brain and breast PET. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 702:129-132. https://doi.org/10.1016/j.nima.2012.08.029 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.nima.2012.08.029 | es_ES |
dc.description.upvformatpinicio | 129 | es_ES |
dc.description.upvformatpfin | 132 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 702 | es_ES |
dc.relation.senia | 230999 | |
dc.contributor.funder | Ministerio de Ciencia e Innovación | es_ES |
dc.contributor.funder | Generalitat Valenciana | es_ES |
dc.contributor.funder | Centro para el Desarrollo Tecnológico Industrial | es_ES |