Del Coz Diaz, JJ.; Lozano Martínez-Luengas, A.; Adam Martínez, JM.; Martín Rodríguez, A. (2011). Nonlinear hygrothermal failure analysis of a masonry external wall by the FEM: A case study. Construction and Building Materials. 25(12):4454-4464. https://doi.org/10.1016/j.conbuildmat.2010.12.039
Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/37714
Title:
|
Nonlinear hygrothermal failure analysis of a masonry external wall by the FEM: A case study
|
Author:
|
Del Coz Diaz, Juan Jose
Lozano Martínez-Luengas, Alfonso
Adam Martínez, José Miguel
Martín Rodríguez, A.
|
UPV Unit:
|
Universitat Politècnica de València. Departamento de Ingeniería de la Construcción y de Proyectos de Ingeniería Civil - Departament d'Enginyeria de la Construcció i de Projectes d'Enginyeria Civil
Universitat Politècnica de València. Instituto de Ciencia y Tecnología del Hormigón - Institut de Ciència i Tecnologia del Formigó
|
Issued date:
|
|
Abstract:
|
This paper presents the case study of a detailed analysis of the failure of an external clay brick wall that had been built in 1995. The failure involved the collapse of a considerable part of the outer wall as well as ...[+]
This paper presents the case study of a detailed analysis of the failure of an external clay brick wall that had been built in 1995. The failure involved the collapse of a considerable part of the outer wall as well as sizeable cracks in the remainder. To determine the cause of the collapse, a preliminary investigation and field survey were carried out, followed by laboratory tests. The diagnosis from the data collected was supplemented by sophisticated non-linear finite element models, which considered both thermal and hygrothermal behaviour of the bricks with which the wall had been built. Moreover, a parametric study and a search for optimal value based on the design of experiments and goal optimisation analysis is done to obtain the hygrothermal behaviour of the existing wall. In this way, transforming our experience in numerical simulation into knowledge, the causes of the external wall failure have been determined. Next, the lessons drawn from the study are given in the final section. (C) 2010 Elsevier Ltd. All rights reserved.
[-]
|
Subjects:
|
External brick wall
,
Concrete
,
Finite element modelling
,
Hygrothermal analysis
,
Case study
|
Copyrigths:
|
Cerrado |
Source:
|
Construction and Building Materials. (issn:
0950-0618
)
|
DOI:
|
10.1016/j.conbuildmat.2010.12.039
|
Publisher:
|
Elsevier
|
Publisher version:
|
http://dx.doi.org/10.1016/j.conbuildmat.2010.12.039
|
Project ID:
|
info:eu-repo/grantAgreement/MICINN//BIA2008-00058/ES/ESTUDIO Y OPTIMIZACION DEL COMPORTAMIENTO HIGRO-TERMICO DE NUEVOS TIPOS DE BLOQUES HUECOS ELABORADOS EN BASE A HORMIGONES LIGEROS PARA SU EMPLEO EN SUELOS Y PAREDES/
info:eu-repo/granAgreement/IUTA//SV-09-GIJON-1-IUTA/ES
|
Thanks:
|
The authors acknowledge the partial financial support provided by the SV-09-GIJON-1-IUTA research fellowship and the Gijon City Council, and the Spanish Ministry of Science and Innovation through the research grant ...[+]
The authors acknowledge the partial financial support provided by the SV-09-GIJON-1-IUTA research fellowship and the Gijon City Council, and the Spanish Ministry of Science and Innovation through the research grant BIA2008-00058. We also thank to Swanson Analysis Inc. for the use of ANSYS Academic program. Finally, we also thank to the interesting comments of the suggested anonymous reviewers.
[-]
|
Type:
|
Artículo
|