Mostrar el registro sencillo del ítem
dc.contributor.author | De Rosario Martínez, Helios | es_ES |
dc.contributor.author | Page Del Pozo, Alvaro Felipe | es_ES |
dc.contributor.author | Besa Gonzálvez, Antonio José | es_ES |
dc.contributor.author | Valera Fernández, Ángel | es_ES |
dc.date.accessioned | 2014-07-16T11:39:49Z | |
dc.date.issued | 2013-10-18 | |
dc.identifier.issn | 0021-9290 | |
dc.identifier.uri | http://hdl.handle.net/10251/38855 | |
dc.description.abstract | This paper presents a mathematical model for the propagation of errors in body segment kinematics to the location of the center of rotation. Three functional calibration techniques, usually employed for the gleno-humeral joint, are studied: the methods based on the pivot of the instantaneous helical axis (PIHA) or the finite helical axis (PFHA), and the ¿symmetrical center of rotation estimation¿ (SCoRE). A procedure for correcting the effect of soft tissue artifacts is also proposed, based on the equations of those techniques and a model of the artifact, like the one that can be obtained by double calibration. An experiment with a mechanical analog was performed to validate the procedure and compare the performance of each technique. The raw error (between 57 and 68 mm) was reduced by a proportion of between 1:6 and less than 1:15, depending on the artifact model and the mathematical method. The best corrections were obtained by the SCoRE method. Some recommendations about the experimental setup for functional calibration techniques and the choice of a mathematical method are derived from theoretical considerations about the formulas and the results of the experiment. | es_ES |
dc.description.sponsorship | This work has been funded by the Spanish Government (Grants DPI2009-13830-C02-01, DPI2009-13830-C02-02, DPI2010-20814-C02-01, and DPI2010-20814-C02-02). | en_EN |
dc.format.extent | 7 | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Journal of Biomechanics | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Soft tissue artifacts | es_ES |
dc.subject | Functional calibration | es_ES |
dc.subject | Center of rotation | es_ES |
dc.subject | Gleno-humeral joint | es_ES |
dc.subject.classification | FISICA APLICADA | es_ES |
dc.subject.classification | INGENIERIA DE SISTEMAS Y AUTOMATICA | es_ES |
dc.subject.classification | INGENIERIA MECANICA | es_ES |
dc.title | Propagation of soft tissue artifacts to the center of rotation: A model for the correction of functional calibration techniques | es_ES |
dc.type | Artículo | es_ES |
dc.embargo.lift | 10000-01-01 | |
dc.embargo.terms | forever | es_ES |
dc.identifier.doi | 10.1016/j.jbiomech.2013.08.006 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//DPI2009-13830-C02-01/ES/Modelado Cinematico Y Dinamico Del Movimiento De Los Tejidos Blandos. Aplicacion Al Diseño De Modelos Biomecanicos (Desarrollo E Implementacion De Modelos)/ / | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//DPI2009-13830-C02-02/ES/Modelado Cinematico Y Dinamico Del Movimiento De Los Tejidos Blandos. Aplicacion Al Diseño De Modelos Biomecanicos (Desarrollo De Tecnicas Experimentales Y Validacion De Modelos)/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//DPI2010-20814-C02-01/ES/IDENTIFICACION DE PARAMETROS DINAMICOS EN VEHICULOS LIGEROS Y ROBOTS MOVILES. APLICACION A LA IDENTIFICACION EN TIEMPO REAL/ / | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//DPI2010-20814-C02-02/ES/IDENTIFICACION DE PARAMETROS DINAMICOS EN VEHICULOS LIGEROS Y ROBOTS MOVILES. APLICACION AL CONTROL Y LA NAVEGACION AUTOMATICA/ / | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Mecánica y de Materiales - Departament d'Enginyeria Mecànica i de Materials | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería de Sistemas y Automática - Departament d'Enginyeria de Sistemes i Automàtica | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto Universitario de Automática e Informática Industrial - Institut Universitari d'Automàtica i Informàtica Industrial | es_ES |
dc.description.bibliographicCitation | De Rosario Martínez, H.; Page Del Pozo, AF.; Besa Gonzálvez, AJ.; Valera Fernández, Á. (2013). Propagation of soft tissue artifacts to the center of rotation: A model for the correction of functional calibration techniques. Journal of Biomechanics. 46(15):2619-2625. doi:10.1016/j.jbiomech.2013.08.006 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.jbiomech.2013.08.006 | es_ES |
dc.description.upvformatpinicio | 2619 | es_ES |
dc.description.upvformatpfin | 2625 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 46 | es_ES |
dc.description.issue | 15 | es_ES |
dc.relation.senia | 250187 | |
dc.contributor.funder | Ministerio de Ciencia e Innovación | es_ES |