Navarro, P.; Morais Ezquerro, SB.; Gavaldón, JA.; Pérez, AJ.; Puchades Pla, R.; Maquieira Catala, Á. (2013). Arrays on disc for screening and quantification of pollutants. Analytica Chimica Acta. 784:59-64. https://doi.org/10.1016/j.aca.2013.04.041
Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/38859
Title:
|
Arrays on disc for screening and quantification of pollutants
|
Author:
|
Navarro, Patricia
Morais Ezquerro, Sergi Beñat
Gavaldón, José A.
Pérez, Antonio J.
Puchades Pla, Rosa
Maquieira Catala, Ángel
|
UPV Unit:
|
Universitat Politècnica de València. Departamento de Química - Departament de Química
Universitat Politècnica de València. Instituto de Reconocimiento Molecular y Desarrollo Tecnológico - Institut de Reconeixement Molecular i Desenvolupament Tecnològic
|
Issued date:
|
|
Abstract:
|
A rapid compact disc based methodology for screening and quantification of organic pollutants in mandarin juices is presented. The assay is established on the coating conjugate indirect competitive principle and developed ...[+]
A rapid compact disc based methodology for screening and quantification of organic pollutants in mandarin juices is presented. The assay is established on the coating conjugate indirect competitive principle and developed under disc-array configuration. The detection is based on the acquisition of attenuated reflective signals that were proportional to optical density of the immunoreaction product. The competitive assay is applied to quantify simultaneously, in a selective manner, non-systemic insecticides in mandarin juices. The detection limits were 0.2 and 0.1 ¿g L¿1 and the sensitivity 2.1 and 1.5 ¿g L¿1, for chlorpyrifos and fenthion, respectively. Pollutants were directly quantified after sample dilution in a total time of 40 min. Also, the implementation of positive and negative controls into the array configuration served as an automatic quality control test. The effect of thermal treatment on pesticide dissipation was studied and found that it was insignificant under the studied conditions. Recovery intervals ranged from 96¿105% to 94¿103%, for chlorpyrifos and fenthion, respectively and were similar to those obtained with gas chromatography coupled to mass spectrometry. In the current configuration, 64 samples can be simultaneously analyzed on a disc at a very competitive value, demonstrating its potential for high-throughput multiplexed screening applications for controlled monitoring programs in low-level labs or outside the lab setting
[-]
|
Subjects:
|
Arrays
,
Compact discs
,
Immunoanalysis
,
Pollutants
|
Copyrigths:
|
Reserva de todos los derechos
|
Source:
|
Analytica Chimica Acta. (issn:
0003-2670
)
|
DOI:
|
10.1016/j.aca.2013.04.041
|
Publisher:
|
Elsevier Masson
|
Publisher version:
|
http://dx.doi.org/10.1016/j.aca.2013.04.041
|
Project ID:
|
info:eu-repo/grantAgreement/MICINN//CTQ2010-15943/ES/ESTUDIO DE NUEVAS VIAS DE DESARROLLO DE BIOMEMS PARA SCREENING MASIVO. DEMOSTRACION DE CONCEPTO COMO HERRAMIENTA DE ANALISIS APLICABLE EN "OMICAS"./
info:eu-repo/grantAgreement/GVA//PROMETEO%2F2010%2F008/ES/AYUDA PARA EL GRUPO SYM-IDM/
info:eu-repo/grantAgreement/GVA//ACOMP%2F2012%2F158/
|
Thanks:
|
This work was funded by the projects FEDER CTQ2010-15943 (CICYT, Spain), and PROMETEO 2010/008 and ACOMP/2012/158 (Generalitat Valenciana).
|
Type:
|