- -

A Voltammetric Electronic Tongue as Tool for Water Quality Monitoring in Wastewater Treatment Plants

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

A Voltammetric Electronic Tongue as Tool for Water Quality Monitoring in Wastewater Treatment Plants

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Campos Sánchez, Inmaculada es_ES
dc.contributor.author Alcañiz Fillol, Miguel es_ES
dc.contributor.author Aguado García, Daniel es_ES
dc.contributor.author Barat Baviera, Ramón es_ES
dc.contributor.author FERRER, J. es_ES
dc.contributor.author Gil Sánchez, Luís es_ES
dc.contributor.author Marrakchi, Mouna es_ES
dc.contributor.author Martínez Mañez, Ramón es_ES
dc.contributor.author Soto Camino, Juan es_ES
dc.contributor.author Vivancos Bono, José Luís es_ES
dc.date.accessioned 2014-07-17T06:18:17Z
dc.date.issued 2012-05-15
dc.identifier.issn 0043-1354
dc.identifier.uri http://hdl.handle.net/10251/38860
dc.description.abstract The use of a voltammetric electronic tongue as tool for the prediction of concentration levels of certain water quality parameters from influent and effluent wastewater from a Submerged Anaerobic Membrane Bioreactor pilot plant applied to domestic wastewater treatment is proposed here. The electronic tongue consists of a set of noble (Au, Pt, Rh, Ir, and Ag) and non-noble (Ni, Co and Cu) electrodes that were housed inside a stainless steel cylinder which was used as the body of the electronic tongue system. As a previous step an electrochemical study of the response of the ions sulphate, orthophosphate, acetate, bicarbonate and ammonium was carried out in water using the electrodes contained in the electronic tongue. The second part of the work was devoted to the application of the electronic tongue to the characterization of the influent and effluent waters from the wastewater treatment plant. Partial Least Squares analysis was used to obtain a correlation between the data from the tongue and the pollution parameters measured in the laboratory such as soluble chemical oxygen demand (CODs), soluble biological oxygen demand (BODs), ammonia (NH 4-N), orthophosphate (PO 4-P), Sulphate (SO 4-S), acetic acid (HAC) and alkalinity (Alk). A total of 28 and 11 samples were used in the training and the validation steps, respectively, for both influent and effluent water samples. The electronic tongue showed relatively good predictive power for the determination of BOD, COD, NH 4-N, PO 4-P, SO 4-S, and Alk. © 2012 Elsevier Ltd. es_ES
dc.description.sponsorship Financial support from the Spanish Government (project MAT2009-14564-C04-01 and PCI-Mediterraneo A/024590/09/A/03044/10), the Generalitat Valenciana (project PROMETEO/2009/016), the MICINN (MAT2009-14564-C04-02) for a research fellowship and the UPV (project PAID-05-10) is gratefully acknowledged. en_EN
dc.format.extent 8 es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Water Research es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Wastewater treatment plants es_ES
dc.subject Wastewater es_ES
dc.subject Monitoring es_ES
dc.subject On-line sensors es_ES
dc.subject Voltammetric electronic tongue es_ES
dc.subject Domestic wastewater es_ES
dc.subject.classification PROYECTOS DE INGENIERIA es_ES
dc.subject.classification QUIMICA ANALITICA es_ES
dc.subject.classification QUIMICA INORGANICA es_ES
dc.subject.classification TECNOLOGIA DEL MEDIO AMBIENTE es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title A Voltammetric Electronic Tongue as Tool for Water Quality Monitoring in Wastewater Treatment Plants es_ES
dc.type Artículo es_ES
dc.embargo.lift 10000-01-01
dc.embargo.terms forever es_ES
dc.identifier.doi 10.1016/j.watres.2012.02.029
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//MAT2009-14564-C04-01/ES/Nanomateriales Hibridos Para El Desarrollo De \"Puertas Moleculares\" De Aplicacion En Procesos De Reconocimiento Y Terapeutica Y Para La Deteccion De Explosivos/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/Generalitat Valenciana//PROMETEO09%2F2009%2F016/ES/Ayuda prometeo 2009 para el grupo de diseño y desarrollo de sensores/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//MAT2009-14564-C04-02/ES/Aproximacion Al Biomimetismo Usando Lenguas Electronicas Y Narices Para La Deteccion De Explosivos Y Agentes Nerviosos/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/UPV// PAID-05-10/ es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Química - Departament de Química es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Hidráulica y Medio Ambiente - Departament d'Enginyeria Hidràulica i Medi Ambient es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Proyectos de Ingeniería - Departament de Projectes d'Enginyeria es_ES
dc.description.bibliographicCitation Campos Sánchez, I.; Alcañiz Fillol, M.; Aguado García, D.; Barat Baviera, R.; Ferrer, J.; Gil Sánchez, L.; Marrakchi, M.... (2012). A Voltammetric Electronic Tongue as Tool for Water Quality Monitoring in Wastewater Treatment Plants. Water Research. 46(8):2605-2614. https://doi.org/10.1016/j.watres.2012.02.029 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/doi:10.1016/j.watres.2012.02.029 es_ES
dc.description.upvformatpinicio 2605 es_ES
dc.description.upvformatpfin 2614 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 46 es_ES
dc.description.issue 8 es_ES
dc.relation.senia 221992
dc.contributor.funder Generalitat Valenciana es_ES
dc.contributor.funder Ministerio de Ciencia e Innovación es_ES
dc.contributor.funder Universitat Politècnica de València


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem