Mostrar el registro sencillo del ítem
dc.contributor.author | Campos Sánchez, Inmaculada | es_ES |
dc.contributor.author | Alcañiz Fillol, Miguel | es_ES |
dc.contributor.author | Aguado García, Daniel | es_ES |
dc.contributor.author | Barat Baviera, Ramón | es_ES |
dc.contributor.author | FERRER, J. | es_ES |
dc.contributor.author | Gil Sánchez, Luís | es_ES |
dc.contributor.author | Marrakchi, Mouna | es_ES |
dc.contributor.author | Martínez Mañez, Ramón | es_ES |
dc.contributor.author | Soto Camino, Juan | es_ES |
dc.contributor.author | Vivancos Bono, José Luís | es_ES |
dc.date.accessioned | 2014-07-17T06:18:17Z | |
dc.date.issued | 2012-05-15 | |
dc.identifier.issn | 0043-1354 | |
dc.identifier.uri | http://hdl.handle.net/10251/38860 | |
dc.description.abstract | The use of a voltammetric electronic tongue as tool for the prediction of concentration levels of certain water quality parameters from influent and effluent wastewater from a Submerged Anaerobic Membrane Bioreactor pilot plant applied to domestic wastewater treatment is proposed here. The electronic tongue consists of a set of noble (Au, Pt, Rh, Ir, and Ag) and non-noble (Ni, Co and Cu) electrodes that were housed inside a stainless steel cylinder which was used as the body of the electronic tongue system. As a previous step an electrochemical study of the response of the ions sulphate, orthophosphate, acetate, bicarbonate and ammonium was carried out in water using the electrodes contained in the electronic tongue. The second part of the work was devoted to the application of the electronic tongue to the characterization of the influent and effluent waters from the wastewater treatment plant. Partial Least Squares analysis was used to obtain a correlation between the data from the tongue and the pollution parameters measured in the laboratory such as soluble chemical oxygen demand (CODs), soluble biological oxygen demand (BODs), ammonia (NH 4-N), orthophosphate (PO 4-P), Sulphate (SO 4-S), acetic acid (HAC) and alkalinity (Alk). A total of 28 and 11 samples were used in the training and the validation steps, respectively, for both influent and effluent water samples. The electronic tongue showed relatively good predictive power for the determination of BOD, COD, NH 4-N, PO 4-P, SO 4-S, and Alk. © 2012 Elsevier Ltd. | es_ES |
dc.description.sponsorship | Financial support from the Spanish Government (project MAT2009-14564-C04-01 and PCI-Mediterraneo A/024590/09/A/03044/10), the Generalitat Valenciana (project PROMETEO/2009/016), the MICINN (MAT2009-14564-C04-02) for a research fellowship and the UPV (project PAID-05-10) is gratefully acknowledged. | en_EN |
dc.format.extent | 8 | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Water Research | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Wastewater treatment plants | es_ES |
dc.subject | Wastewater | es_ES |
dc.subject | Monitoring | es_ES |
dc.subject | On-line sensors | es_ES |
dc.subject | Voltammetric electronic tongue | es_ES |
dc.subject | Domestic wastewater | es_ES |
dc.subject.classification | PROYECTOS DE INGENIERIA | es_ES |
dc.subject.classification | QUIMICA ANALITICA | es_ES |
dc.subject.classification | QUIMICA INORGANICA | es_ES |
dc.subject.classification | TECNOLOGIA DEL MEDIO AMBIENTE | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.title | A Voltammetric Electronic Tongue as Tool for Water Quality Monitoring in Wastewater Treatment Plants | es_ES |
dc.type | Artículo | es_ES |
dc.embargo.lift | 10000-01-01 | |
dc.embargo.terms | forever | es_ES |
dc.identifier.doi | 10.1016/j.watres.2012.02.029 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//MAT2009-14564-C04-01/ES/Nanomateriales Hibridos Para El Desarrollo De \"Puertas Moleculares\" De Aplicacion En Procesos De Reconocimiento Y Terapeutica Y Para La Deteccion De Explosivos/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/Generalitat Valenciana//PROMETEO09%2F2009%2F016/ES/Ayuda prometeo 2009 para el grupo de diseño y desarrollo de sensores/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//MAT2009-14564-C04-02/ES/Aproximacion Al Biomimetismo Usando Lenguas Electronicas Y Narices Para La Deteccion De Explosivos Y Agentes Nerviosos/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/UPV// PAID-05-10/ | es_ES |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Química - Departament de Química | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Hidráulica y Medio Ambiente - Departament d'Enginyeria Hidràulica i Medi Ambient | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Proyectos de Ingeniería - Departament de Projectes d'Enginyeria | es_ES |
dc.description.bibliographicCitation | Campos Sánchez, I.; Alcañiz Fillol, M.; Aguado García, D.; Barat Baviera, R.; Ferrer, J.; Gil Sánchez, L.; Marrakchi, M.... (2012). A Voltammetric Electronic Tongue as Tool for Water Quality Monitoring in Wastewater Treatment Plants. Water Research. 46(8):2605-2614. https://doi.org/10.1016/j.watres.2012.02.029 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/doi:10.1016/j.watres.2012.02.029 | es_ES |
dc.description.upvformatpinicio | 2605 | es_ES |
dc.description.upvformatpfin | 2614 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 46 | es_ES |
dc.description.issue | 8 | es_ES |
dc.relation.senia | 221992 | |
dc.contributor.funder | Generalitat Valenciana | es_ES |
dc.contributor.funder | Ministerio de Ciencia e Innovación | es_ES |
dc.contributor.funder | Universitat Politècnica de València |