Campos Sánchez, I.; Alcañiz Fillol, M.; Masot Peris, R.; Soto Camino, J.; Martínez Mañez, R.; Vivancos, J.; Gil Sánchez, L. (2012). A method of pulse array design for voltammetric electronic tongues. Sensors and Actuators B: Chemical. 161(1):556-563. https://doi.org/10.1016/j.snb.2011.10.075
Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/39667
Título:
|
A method of pulse array design for voltammetric electronic tongues
|
Autor:
|
Campos Sánchez, Inmaculada
Alcañiz Fillol, Miguel
Masot Peris, Rafael
Soto Camino, Juan
Martínez Mañez, Ramón
Vivancos, José-Luís
Gil Sánchez, Luís
|
Entidad UPV:
|
Universitat Politècnica de València. Instituto de Reconocimiento Molecular y Desarrollo Tecnológico - Institut de Reconeixement Molecular i Desenvolupament Tecnològic
Universitat Politècnica de València. Departamento de Química - Departament de Química
Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica
Universitat Politècnica de València. Departamento de Proyectos de Ingeniería - Departament de Projectes d'Enginyeria
|
Fecha difusión:
|
|
Resumen:
|
This paper proposes a reasonable methodology for the design of pulse arrays applied in classification and quantification techniques based on the use of pulse voltammetric electronic tongues. As model problem we designed a ...[+]
This paper proposes a reasonable methodology for the design of pulse arrays applied in classification and quantification techniques based on the use of pulse voltammetric electronic tongues. As model problem we designed a procedure to predict levels of ferrocene, TCNQ and Ru(bipy)(3)(2+) using a voltammetric electronic tongue employing a set of noble electrodes; i.e. Au, Pt, Ir and Rh. Ferrocene, TCNQ and Ru(bipy)(3)(2+) have been selected as model compounds because these are molecules with well-defined redox processes. The electrodes were housed inside a stainless steel cylinder which was used as the body of the electronic tongue system. A SCE was used as reference electrode. An electrochemical study of the response of ferrocene TCNQ and Ru(bipy)(3)(2+) was carried out as a first step with the aim of characterise the redox processes in these compounds. Different samples containing ferrocene,TCNQ and Ru(bipy)(3)(2+) were prepared following an experimental design in which a system of three compounds/three levels was established. Multivariate analysis based on Partial Least Square (PLS) techniques was applied for data management and prediction models building. Several set of pulses were tested and a general procedure to their design for their use in voltammetric electronic tongues is discussed and proposed. (C) 2011 Elsevier B.V. All rights reserved.
[-]
|
Palabras clave:
|
Electronic tongues
,
Voltammetry
,
Array design
,
Electrochemical studies
,
Ferrocenes
,
Model compound
,
Model problems
,
Multi variate analysis
,
Partial least squares
,
Prediction model
,
Redox process
,
Reference electrodes
,
Stainless steel cylinders
,
Voltammetric electronic tongue
,
Design
,
Electrodes
,
Electronic voltmeters
,
Information management
,
Iridium
,
Iron compounds
,
Mathematical models
,
Multivariant analysis
,
Organometallics
,
Platinum
,
Rhodium
,
Stainless steel
|
Derechos de uso:
|
Cerrado |
Fuente:
|
Sensors and Actuators B: Chemical. (issn:
0925-4005
)
|
DOI:
|
10.1016/j.snb.2011.10.075
|
Editorial:
|
Elsevier
|
Versión del editor:
|
http://dx.doi.org/10.1016/j.snb.2011.10.075
|
Código del Proyecto:
|
info:eu-repo/grantAgreement/MICINN//MAT2009-14564-C04-01/ES/Nanomateriales Hibridos Para El Desarrollo De \"Puertas Moleculares\" De Aplicacion En Procesos De Reconocimiento Y Terapeutica Y Para La Deteccion De Explosivos/
info:eu-repo/grantAgreement/Generalitat Valenciana//PROMETEO09%2F2009%2F016/ES/Ayuda prometeo 2009 para el grupo de diseño y desarrollo de sensores/
info:eu-repo/grantAgreement/MAEC//A%2F024590%2F09/ES/CONTROL DE CALIDAD PARA LA REUTILIZACIÓN DE AGUAS DEPURADAS PARA RIEGO AGRÍCOLA/
info:eu-repo/grantAgreement/UPV//PAID-05-10/
|
Agradecimientos:
|
We thank the Spanish Government (projects MAT2009-14564-C04-01), Generalitat Valenciana (project PROMETEO/2009/016) for support. PCI-Mediterraneo A/024590/09/A/03044/10) and the UPV (project PAID-05-10) are gratefully ...[+]
We thank the Spanish Government (projects MAT2009-14564-C04-01), Generalitat Valenciana (project PROMETEO/2009/016) for support. PCI-Mediterraneo A/024590/09/A/03044/10) and the UPV (project PAID-05-10) are gratefully acknowledged.
[-]
|
Tipo:
|