Mostrar el registro sencillo del ítem
dc.contributor.author | Gutiérrez Ortiz de la Tabla, Javier | es_ES |
dc.contributor.author | Mas Tomas, Maria de los Angeles | es_ES |
dc.contributor.author | Gil Benso, Enrique | es_ES |
dc.contributor.author | Galvañ Llopis, Vicente | es_ES |
dc.date.accessioned | 2014-10-27T14:00:23Z | |
dc.date.available | 2014-10-27T14:00:23Z | |
dc.date.issued | 2012-04 | |
dc.identifier.issn | 0950-0618 | |
dc.identifier.uri | http://hdl.handle.net/10251/43599 | |
dc.description.abstract | Clay particles found in many building stones, when in contact with water, suffer aggregation-disaggregation and swelling-shrinking processes which can cause severe pathology. Whilst research has focused on historic buildings and masonry walls, studies regarding rainscreen walls are lacking. When using panels of reduced thickness fixed with punctual anchorage points, fissures or scaling phenomena can rapidly lead to rupture of panels, causing stability failure. This study aims to identify the causes of decay in a building with limestone rainscreen walls, in order to help to understand clay-related damage in this type of façade and its differences with regard to masonry walls. © 2011 Elsevier Ltd. All rights reserved. | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Construction and Building Materials | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Clay | es_ES |
dc.subject | Damage | es_ES |
dc.subject | Decay | es_ES |
dc.subject | Rainscreen | es_ES |
dc.subject | Stone | es_ES |
dc.subject | Façade | es_ES |
dc.subject | Cladding (coating) | es_ES |
dc.subject | Masonry construction | es_ES |
dc.subject | Retaining walls | es_ES |
dc.subject.classification | MECANICA DE LOS MEDIOS CONTINUOS Y TEORIA DE ESTRUCTURAS | es_ES |
dc.subject.classification | CONSTRUCCIONES ARQUITECTONICAS | es_ES |
dc.title | Clay-related damage in rainscreen walls built with natural stone coverings | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.conbuildmat.2011.10.060 | |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Arquitectura - Escola Tècnica Superior d'Arquitectura | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Construcciones Arquitectónicas - Departament de Construccions Arquitectòniques | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Mecánica de los Medios Continuos y Teoría de Estructuras - Departament de Mecànica dels Medis Continus i Teoria d'Estructures | es_ES |
dc.description.bibliographicCitation | Gutiérrez Ortiz De La Tabla, J.; Mas Tomas, MDLA.; Gil Benso, E.; Galvañ Llopis, V. (2012). Clay-related damage in rainscreen walls built with natural stone coverings. Construction and Building Materials. 29:357-367. doi:10.1016/j.conbuildmat.2011.10.060 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.conbuildmat.2011.10.060 | es_ES |
dc.description.upvformatpinicio | 357 | es_ES |
dc.description.upvformatpfin | 367 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 29 | es_ES |
dc.relation.senia | 206028 |