- -

Simulation of moisture alarm for district heating networks

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Simulation of moisture alarm for district heating networks

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Cehlin, Mathias es_ES
dc.contributor.author Guillem Reig, Santiago es_ES
dc.date.accessioned 2014-11-03T12:53:51Z
dc.date.available 2014-11-03T12:53:51Z
dc.date.created 2014-09
dc.date.issued 2014-11-03T12:53:51Z
dc.identifier.uri http://hdl.handle.net/10251/43813
dc.description.abstract Consulta en la Biblioteca ETSI Industriales (Riunet) es_ES
dc.description.abstract [EN] This master thesis hopes to be a first approach in the study of the moisture control of the district heating networks. Nowadays the moisture control is based on the resistance value analysis and the time-domain reflectometer usage. These two technic has been proved to be an effective combination in order to detect and localize leakages in the networks. Despite this fact, there is not a wide knowledge about the actual behaviour of this system and the influence of different factors to the system, such as the differentiation between internal and external leakage, the control of the time influence in the system or the external condition influence in control. In order to increase the knowledge of theses two systems and their relation with the system variables, different tests were developed. These tests can be divided into two main groups; the first ones were related with the moisture alarm behaviour in different moisture conditions (related with time, volume and dimensions) while the second group was related with the pipe isolation water absorption for different salt concentrations. The combination of these tests have made the perception of the importance of the time control in the moisture alarm possible due to the facts that the moisture is transferred through the isolation with low speed ratios and that the moisture alarm has showed some limitations. At the same time the study of the alarm reaction to different moisture states has shown a relation between the moisture conditions and alarm results. These results make the idea of a future better knowledge of the network real state based on the time control, the variables study and the moisture alarm reaction possible. But in order to be able to reach this knowledge, some other studies and tests related with the moisture alarm are needed. es_ES
dc.language Inglés es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Consulta en la Biblioteca ETSI Industriales es_ES
dc.subject Redes de calefacción urbana es_ES
dc.subject Sistemas de alarma es_ES
dc.subject.classification INGENIERIA DE SISTEMAS Y AUTOMATICA es_ES
dc.subject.other Ingeniero Industrial-Enginyer Industrial es_ES
dc.title Simulation of moisture alarm for district heating networks es_ES
dc.type Proyecto/Trabajo fin de carrera/grado es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Guillem Reig, S. (2014). Simulation of moisture alarm for district heating networks. http://hdl.handle.net/10251/43813. es_ES
dc.description.accrualMethod Archivo delegado es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem