Alcaraz, R.; Hornero, F.; Rieta, JJ. (2011). Assessment of non-invasive time and frequency atrial fibrillation organization markers with unipolar atrial electrograms. Physiological Measurement. 32(1):99-114. doi:10.1088/0967-3334/32/1/007
Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/43899
Título:
|
Assessment of non-invasive time and frequency atrial fibrillation organization markers with unipolar atrial electrograms
|
Autor:
|
Alcaraz, Raúl
Hornero, Fernando
Rieta, J J
|
Entidad UPV:
|
Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica
|
Fecha difusión:
|
|
Resumen:
|
The standard electrocardiogram (ECG) is the most common non-invasive way to study atrial fibrillation (AF). In this respect, previous works have shown that the surface lead V 1 reflects mainly the dominant atrial frequency ...[+]
The standard electrocardiogram (ECG) is the most common non-invasive way to study atrial fibrillation (AF). In this respect, previous works have shown that the surface lead V 1 reflects mainly the dominant atrial frequency (DAF) of the right atrium (RA), which has been widely used to study AF. In a similar way, AF organization and fibrillatory (f) wave amplitude are two recently proposed non-invasive AF markers. These markers need to be validated with invasive recordings in order to assess their capability to reliably reflect the internal fibrillatory activity dynamics. In this work, these two non-invasive metrics have been compared with similar measures recorded from two unipolar atrial electrograms (AEGs). For both ECG and AEG signals, AF organization has been computed by applying a nonlinear regularity index, such as sample entropy (SampEn), to the atrial activity (AA) and to its fundamental waveform, defined as the main atrial wave (MAW). The surface and epicardial f wave amplitude has been estimated through their mean power. Results obtained for 38 patients showed statistically significant correlations between the values measured from surface and invasive recordings, thus corroborating the usefulness of the aforesaid markers in the non-invasive study of AF. Precisely, for AF organization computed from the MAW, the correlation coefficients between surface and both AEGs were R = 0.926 (p < 0.001) and R = 0.932 (p < 0.001). For f wave amplitude, slightly lower significant relationships were noticed, the correlation coefficients being R = 0.765 (p < 0.001) and R = 0.842 (p < 0.001). These outcomes together with interesting linear relationships found among the parameters suggest that AF regularity estimated via SampEn and f wave amplitude can non-invasively characterize the epicardial activity related to AF. © 2011 Institute of Physics and Engineering in Medicine.
[-]
|
Palabras clave:
|
Atrial fibrillation
,
Dominant atrial frequency
,
Electrocardiogram
,
Electrograms
,
Fibrillatory wave potency
,
Main atrial wave
,
Organization
,
Article
,
Electrocardiography
,
Entropy
,
Heart atrium
,
Heart atrium fibrillation
,
Heart function test
,
Human
,
Instrumentation
,
Methodology
,
Pathophysiology
,
Time
,
Electrophysiologic Techniques, Cardiac
,
Heart Atria
,
Humans
,
Time Factors
|
Derechos de uso:
|
Cerrado |
Fuente:
|
Physiological Measurement. (issn:
0967-3334
)
|
DOI:
|
10.1088/0967-3334/32/1/007
|
Editorial:
|
IOP Publishing: Hybrid Open Access
|
Versión del editor:
|
http://dx.doi.org/10.1088/0967-3334/32/1/007
|
Código del Proyecto:
|
info:eu-repo/grantAgreement/MEC//TEC2007-64884/ES/SINERGIA DE METODOS LINEALES Y NO LINEALES PARA EL ANALISIS, ESTRATIFICACION Y PREDICCION DEL COMPORTAMIENTO DE LA FIBRILACION AURICULAR/ /
info:eu-repo/grantAgreement/Junta de Comunidades de Castilla-La Mancha//PII1C09-0036-3237/ES/Predicción De Riesgo De Muerte Súbita Tras Infarto De Miocardio Mediante Técnicas Avanzadas De Procesado Digital De Señal/ /
info:eu-repo/grantAgreement/Junta de Comunidades de Castilla-La Mancha//PII2C09-0224-5983/ES/Aplicación De Metodologías No Lineales Para La Estimación Robusta Y No Invasiva De La Organización En Fibrilación Auricular/
info:eu-repo/grantAgreement/MICINN//TEC2010-20633/ES/DESARROLLO Y APLICACION DE ESTIMADORES AVANZADOS DE ORGANIZACION PARA LA CLASIFICACION TERAPEUTICA Y EL SEGUIMIENTO DE PACIENTES CON FIBRILACION AURICULAR/
info:eu-repo/grantAgreement/Junta de Comunidades de Castilla-La Mancha//PPII11-0194-8121]/ES/PPII11-0194-8121]/
|
Agradecimientos:
|
This work was supported by projects TEC2007-64884 and TEC2010-20633 from the Spanish Ministry of Science and Innovation, PII2C09-0224-5983, PPII11-0194-8121 and PII1C09-0036-3237 from Junta de Comunidades de Castilla La Mancha.[+]
This work was supported by projects TEC2007-64884 and TEC2010-20633 from the Spanish Ministry of Science and Innovation, PII2C09-0224-5983, PPII11-0194-8121 and PII1C09-0036-3237 from Junta de Comunidades de Castilla La Mancha.
[-]
|
Tipo:
|
Artículo
|