- -

Acoustic position calibration of the KM3NeT neutrino telescope

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Acoustic position calibration of the KM3NeT neutrino telescope

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Larosa, Giuseppina es_ES
dc.contributor.author Ardid Ramírez, Miguel es_ES
dc.contributor.author KM3NeT Consortium
dc.date.accessioned 2014-12-12T14:31:41Z
dc.date.available 2014-12-12T14:31:41Z
dc.date.issued 2013-08-01
dc.identifier.issn 0168-9002
dc.identifier.uri http://hdl.handle.net/10251/45404
dc.description.abstract [EN] KM3NeT is a future neutrino telescope with a volume of several cubic kilometres at the bottom of the Mediterranean Sea. It will be composed of at least 300 vertical structures of several hundred metres length, named detection units (DU), anchored on the seabed and kept vertical with a buoy. The DU will host optical sensors able to detect the faint Cherenkov light emitted in the deep sea by charged particles originating from collisions of the neutrinos with nuclei in the sea water or the rock below. A precise knowledge of the optical sensor positions relative to each other, not worse than 20 cm, is needed for an accurate reconstruction of the charged particle tracks. Since the marine currents cause movements of the DUs and thus a displacement of the optical sensors of up to several tens of metres from their nominal positions, an Acoustic Positioning System (APS) is necessary to monitor their positions in deep sea. The KM3NeT APS will be composed of acoustic transceivers at fixed positions on the sea floor and acoustic receivers (hydrophones) along each DU. The hydrophone positions are determined by triangulation using the travel times of acoustic signals between emitters and receivers. This paper presents the acoustic positioning system designed for KM3NeT and in particular the innovative technologies used for transducers, electronics, and signal processing. (C) 2012 Elsevier B.V. All rights reserved. es_ES
dc.description.sponsorship This work has been supported by the Ministerio de Ciencia e Innovación (Spanish Government), project references FPA2009-13983-C02-02, ACI2009-1067, AIC10-D-00583, Consolider-Ingenio Multidark (CSD2009-00064). It has also been funded by Generalitat Valenciana, Prometeo/2009/26, and the European 7th Framework Programme, Grant no. 212525. es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Underwater neutrino telescope es_ES
dc.subject KM3NeT es_ES
dc.subject Calibration es_ES
dc.subject Acoustic positioning system es_ES
dc.subject Transceiver es_ES
dc.subject Hydrophone es_ES
dc.subject.classification FISICA APLICADA es_ES
dc.title Acoustic position calibration of the KM3NeT neutrino telescope es_ES
dc.type Artículo es_ES
dc.type Comunicación en congreso es_ES
dc.identifier.doi 10.1016/j.nima.2012.11.176
dc.relation.projectID info:eu-repo/grantAgreement/EC/FP7/212525/EU/Preparatory Phase for a Deep Sea Facility in the Mediterranean for Neutrino Astronomy and Associated Sciences/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//FPA2009-13983-C02-02/ES/Participacion Del Igic En Los Telescopios De Neutrinos Antares Y Km3Net/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//AIC10-D-000583/ES/COLABORACIÓN UPV-CPPM PARA EL DESARROLLO DEL SISTEMA DE POSICIONAMIENTO DE KM3NET Y ANÁLISIS DE DATOS DE ANTARES/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//CSD2009-00064/ES/Método de Multimensajeros para la Detección de la Materia Oscura/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//ACI2009-1067/ES/Contribución al sistema de posicionamiento de KM3NeT, telescopio de neutrinos en el Mediterráneo/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//PROMETEO09%2F2009%2F026/ES/Telescopios de neutrinos en el Mediterráneo (Telneu)/
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Investigación para la Gestión Integral de Zonas Costeras - Institut d'Investigació per a la Gestió Integral de Zones Costaneres es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada es_ES
dc.description.bibliographicCitation Larosa, G.; Ardid Ramírez, M.; KM3NeT Consortium (2013). Acoustic position calibration of the KM3NeT neutrino telescope. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 718:502-503. https://doi.org/10.1016/j.nima.2012.11.176 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1016/j.nima.2012.11.176 es_ES
dc.description.upvformatpinicio 502 es_ES
dc.description.upvformatpfin 503 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 718 es_ES
dc.relation.senia 254051
dc.contributor.funder European Commission
dc.contributor.funder Ministerio de Ciencia e Innovación
dc.contributor.funder Generalitat Valenciana


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem