dc.description.abstract | [EN] Partial discharge (PD) cable field tests require the use of high frequency sensors coupled to the cable for PD apparent charge evaluation. PD sensors can be coupled to the cable by magnetic field, like high frequency current transformers, or by electric field, like capacitive couplers. If high sensitivity and high bandwidth are required, then capacitive couplers need to be employed since high frequency current transformers exhibit a limitation concerning bandwidth and gain. This paper summarizes some capacitive couplers topologies, their drawbacks and their benefits, and finally proposes a topology based on high voltage capacitors and operational amplifiers. The topology described in this paper allows obtaining a capacitive coupler with a low cutoff frequency in the range of a few kHz and a high cutoff frequency in the range of tens of MHz. The bandwidth achieved with this topology makes possible a reliable PD pulse wave shape record, useful for mathematical post processing, and exhibits a good sensitivity, improving PD field test measures, in both off-line and on-line tests. | es_ES |
dc.description.sponsorship | This work has been partially supported by IMPIVA (Instituto de la Mediana y Pequena Empresa Valenciana) which is attached to the "Conselleria de Industria, Comercio e Innovacion" of the Valencia Regional Government (Industry, Trade and Innovation Regional Minister) and the European Social Fund (ESF) with reference number IMDEEC/2011/2. | |
dc.language | Inglés | es_ES |
dc.publisher | Institute of Electrical and Electronics Engineers (IEEE) | es_ES |
dc.relation.ispartof | IEEE Transactions on Dielectrics and Electrical Insulation | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Charge measurement | es_ES |
dc.subject | High frequency | es_ES |
dc.subject | Capacitive couplers | es_ES |
dc.subject | Partial discharges | es_ES |
dc.subject.classification | INGENIERIA ELECTRICA | es_ES |
dc.title | High Performance Broadband Capacitive Coupler for Partial Discharge Cable Tests | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1109/TDEI.2013.6508750 | |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//IMDEEC%2F2011%2F2/ | es_ES |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Eléctrica - Departament d'Enginyeria Elèctrica | es_ES |
dc.description.bibliographicCitation | Rodrigo Mor, A.; Llovera Segovia, P.; Fuster Roig, VL.; Quijano Lopez, A. (2013). High Performance Broadband Capacitive Coupler for Partial Discharge Cable Tests. IEEE Transactions on Dielectrics and Electrical Insulation. 20(2):479-487. https://doi.org/10.1109/TDEI.2013.6508750 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1109/TDEI.2013.6508750 | es_ES |
dc.description.upvformatpinicio | 479 | es_ES |
dc.description.upvformatpfin | 487 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 20 | es_ES |
dc.description.issue | 2 | es_ES |
dc.relation.senia | 246455 | |
dc.contributor.funder | Instituto de la Pequeña y Mediana Industria de la Generalitat Valenciana |