- -

Ammonium and Phosphate Quantification in Wastewater by Using a Voltammetric Electronic Tongue

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Ammonium and Phosphate Quantification in Wastewater by Using a Voltammetric Electronic Tongue

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Campos Sánchez, Inmaculada es_ES
dc.contributor.author Sangrador, Ana es_ES
dc.contributor.author Bataller Prats, Román es_ES
dc.contributor.author Aguado García, Daniel es_ES
dc.contributor.author Barat Baviera, Ramón es_ES
dc.contributor.author Soto Camino, Juan es_ES
dc.contributor.author Martínez Mañez, Ramón es_ES
dc.date.accessioned 2015-02-04T08:00:03Z
dc.date.issued 2014-03
dc.identifier.issn 1040-0397
dc.identifier.uri http://hdl.handle.net/10251/46701
dc.description.abstract Ammonia (NH4 N) and orthophosphate (PO4 P) quantification in wastewater treatment plants is important due to their implication in the eutrophication process. A voltammetric electronic tongue as a tool for the prediction of ammonia and orthophosphate concentrations from influent and effluent wastewater is proposed herein. An electrochemical study of the response of the ammonium and orthophosphate ions was performed in order to design a suitable waveform for each electrode. Partial Least Squares analysis was used to obtain a correlation between the data from the tongue and the concentrations of ammonia and orthophosphate measured in the laboratory showing good predictive power. es_ES
dc.description.sponsorship Financial support from the Spanish Government (Project MAT2012-38429-C04-01) and the Generalitat Valencia (Project PROMETEO/2009/016) is gratefully acknowledged. en_EN
dc.language Inglés es_ES
dc.publisher Wiley-VCH Verlag es_ES
dc.relation.ispartof Electroanalysis es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Ammonium detection es_ES
dc.subject Orthophosphate detection es_ES
dc.subject Electronic tongue es_ES
dc.subject Partial Least Squares (PLS) analysis es_ES
dc.subject.classification QUIMICA INORGANICA es_ES
dc.subject.classification QUIMICA ANALITICA es_ES
dc.subject.classification TECNOLOGIA DEL MEDIO AMBIENTE es_ES
dc.title Ammonium and Phosphate Quantification in Wastewater by Using a Voltammetric Electronic Tongue es_ES
dc.type Artículo es_ES
dc.embargo.lift 10000-01-01
dc.embargo.terms forever es_ES
dc.identifier.doi 10.1002/elan.201300538
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//MAT2012-38429-C04-01/ES/DESARROLLO DE MATERIALES FUNCIONALIZADOS CON PUERTAS NANOSCOPICAS PARA APLICACIONES DE LIBERACION CONTROLADA Y SENSORES PARA LA DETECCION DE NITRATO AMONICO, SULFIDRICO Y CO/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/Generalitat Valenciana//PROMETEO09%2F2009%2F016/ES/Ayuda prometeo 2009 para el grupo de diseño y desarrollo de sensores/ es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Química - Departament de Química es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Reconocimiento Molecular y Desarrollo Tecnológico - Institut de Reconeixement Molecular i Desenvolupament Tecnològic es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Hidráulica y Medio Ambiente - Departament d'Enginyeria Hidràulica i Medi Ambient es_ES
dc.description.bibliographicCitation Campos Sánchez, I.; Sangrador, A.; Bataller Prats, R.; Aguado García, D.; Barat Baviera, R.; Soto Camino, J.; Martínez Mañez, R. (2014). Ammonium and Phosphate Quantification in Wastewater by Using a Voltammetric Electronic Tongue. Electroanalysis. 26(3):588-595. https://doi.org/10.1002/elan.201300538 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1002/elan.201300538 es_ES
dc.description.upvformatpinicio 588 es_ES
dc.description.upvformatpfin 595 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 26 es_ES
dc.description.issue 3 es_ES
dc.relation.senia 265497
dc.contributor.funder Generalitat Valenciana es_ES
dc.contributor.funder Ministerio de Economía y Competitividad es_ES
dc.description.references Ruano, M. V., Ribes, J., Seco, A., & Ferrer, J. (2009). Low cost-sensors as a real alternative to on-line nitrogen analysers in continuous systems. Water Science and Technology, 60(12), 3261-3268. doi:10.2166/wst.2009.607 es_ES
dc.description.references Winquist, F., Olsson, J., & Eriksson, M. (2011). Multicomponent analysis of drinking water by a voltammetric electronic tongue. Analytica Chimica Acta, 683(2), 192-197. doi:10.1016/j.aca.2010.10.027 es_ES
dc.description.references Zeravik, J., Hlavacek, A., Lacina, K., & Skládal, P. (2009). State of the Art in the Field of Electronic and Bioelectronic Tongues â Towards the Analysis of Wines. Electroanalysis, 21(23), 2509-2520. doi:10.1002/elan.200900285 es_ES
dc.description.references Cole, M., Covington, J. A., & Gardner, J. W. (2011). Combined electronic nose and tongue for a flavour sensing system. Sensors and Actuators B: Chemical, 156(2), 832-839. doi:10.1016/j.snb.2011.02.049 es_ES
dc.description.references Ciosek, P., & Wróblewski, W. (2007). Sensor arrays for liquid sensing – electronic tongue systems. The Analyst, 132(10), 963. doi:10.1039/b705107g es_ES
dc.description.references Mimendia, A., Gutiérrez, J. M., Leija, L., Hernández, P. R., Favari, L., Muñoz, R., & del Valle, M. (2010). A review of the use of the potentiometric electronic tongue in the monitoring of environmental systems. Environmental Modelling & Software, 25(9), 1023-1030. doi:10.1016/j.envsoft.2009.12.003 es_ES
dc.description.references Sipos, L., Kovács, Z., Sági-Kiss, V., Csiki, T., Kókai, Z., Fekete, A., & Héberger, K. (2012). Discrimination of mineral waters by electronic tongue, sensory evaluation and chemical analysis. Food Chemistry, 135(4), 2947-2953. doi:10.1016/j.foodchem.2012.06.021 es_ES
dc.description.references Raud, M., & Kikas, T. (2013). Bioelectronic tongue and multivariate analysis: A next step in BOD measurements. Water Research, 47(7), 2555-2562. doi:10.1016/j.watres.2013.02.026 es_ES
dc.description.references Kirsanov, D., Zadorozhnaya, O., Krasheninnikov, A., Komarova, N., Popov, A., & Legin, A. (2013). Water toxicity evaluation in terms of bioassay with an Electronic Tongue. Sensors and Actuators B: Chemical, 179, 282-286. doi:10.1016/j.snb.2012.09.106 es_ES
dc.description.references Tønning, E., Sapelnikova, S., Christensen, J., Carlsson, C., Winther-Nielsen, M., Dock, E., … Emnéus, J. (2005). Chemometric exploration of an amperometric biosensor array for fast determination of wastewater quality. Biosensors and Bioelectronics, 21(4), 608-617. doi:10.1016/j.bios.2004.12.023 es_ES
dc.description.references Campos, I., Alcañiz, M., Aguado, D., Barat, R., Ferrer, J., Gil, L., … Vivancos, J.-L. (2012). A voltammetric electronic tongue as tool for water quality monitoring in wastewater treatment plants. Water Research, 46(8), 2605-2614. doi:10.1016/j.watres.2012.02.029 es_ES
dc.description.references Giménez, J. B., Robles, A., Carretero, L., Durán, F., Ruano, M. V., Gatti, M. N., … Seco, A. (2011). Experimental study of the anaerobic urban wastewater treatment in a submerged hollow-fibre membrane bioreactor at pilot scale. Bioresource Technology, 102(19), 8799-8806. doi:10.1016/j.biortech.2011.07.014 es_ES
dc.description.references Alcañiz, M., Vivancos, J.-L., Masot, R., Ibañez, J., Raga, M., Soto, J., & Martínez-Máñez, R. (2012). Design of an electronic system and its application to electronic tongues using variable amplitude pulse voltammetry and impedance spectroscopy. Journal of Food Engineering, 111(1), 122-128. doi:10.1016/j.jfoodeng.2012.01.014 es_ES
dc.description.references Winquist, F., Wide, P., & Lundström, I. (1997). An electronic tongue based on voltammetry. Analytica Chimica Acta, 357(1-2), 21-31. doi:10.1016/s0003-2670(97)00498-4 es_ES
dc.description.references Shatkay, A. (1969). Activity of phosphate ions measured with phosphate electrodes of the second kind. Analytical Biochemistry, 29(2), 311-322. doi:10.1016/0003-2697(69)90315-7 es_ES
dc.description.references Zou, Z., Han, J., Jang, A., Bishop, P. L., & Ahn, C. H. (2007). A disposable on-chip phosphate sensor with planar cobalt microelectrodes on polymer substrate. Biosensors and Bioelectronics, 22(9-10), 1902-1907. doi:10.1016/j.bios.2006.08.004 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem