dc.description.abstract | The installed capacity of an air conditioning system is usually higher than the average cooling or heating demand along the year. So, most of the time, the system is working under its actual capacity. In this contribution, we study the way to improve the efficiency of a ground coupled heat pump air conditioning system by adapting its produced thermal energy to the actual thermal demand. For this purpose, an air conditioning system composed by a ground coupled heat pump and a central fan coil linked to an office located in a cooling dominated area was simulated, and a new management strategy aiming to diminish electrical consumption was developed under the basic constraint that comfort requirements are kept. This strategy takes advantage of the possibility of managing the air flow in the fan, the water mass flows in the internal and external hydraulic systems, and the set point temperature in the heat pump to achieve this objective. The electrical consumption of the system is calculated for the new management strategy and compared with the results obtained for a conventional one, resulting in estimated energy savings around 30% | es_ES |
dc.description.sponsorship | This work has been supported by the Spanish Government under projects "Modelado y simulacion de sistemas energeticos complejos" (2005 Ramon y Cajal program), "Modelado, simulacion y validacion experimental de la transferencia de calor en el entorno de la edificacion" (ENE2008-0059/CON). A. Sala is grateful to the financial support of grants DPI2008-06731-c02-01 (Spanish Government), and Generalitat Valenciana Prometeo/2008/088. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Applied Thermal Engineering | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Energy efficiency | es_ES |
dc.subject | Ground coupled heat pump | es_ES |
dc.subject | Numerical simulation | es_ES |
dc.subject.classification | INGENIERIA DE SISTEMAS Y AUTOMATICA | es_ES |
dc.subject.classification | MAQUINAS Y MOTORES TERMICOS | es_ES |
dc.subject.classification | FISICA APLICADA | es_ES |
dc.title | Efficiency improvement of a ground coupled heat pump system from energy management | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.applthermaleng.2010.09.016 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MEC//RyC-2005/ES/Modelado y simulación de sistemas energéticos complejos/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//PROMETEO08%2F2008%2F088/ES/Nuevas Estrategias para el Diseño de Sistemas de Control Multivariable/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//DPI2008-06731-C02-01/ES/IDENTIFICACION Y CONTROL DE SISTEMAS NO LINEALES Y LTV MEDIANTE MULTI-MODELOS TAKAGI-SUGENO Y POLINOMIALES/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//ENE2008-00599/ES/MODELADO, SIMULACION Y VALIDACION EXPERIMENTAL DE LA TRANSFERENCIA DE CALOR EN EL ENTORNO DE LA EDIFICACION/ | |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Ingeniería Energética - Institut d'Enginyeria Energètica | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto Universitario de Automática e Informática Industrial - Institut Universitari d'Automàtica i Informàtica Industrial | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto Universitario de Matemática Pura y Aplicada - Institut Universitari de Matemàtica Pura i Aplicada | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Termodinámica Aplicada - Departament de Termodinàmica Aplicada | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería de Sistemas y Automática - Departament d'Enginyeria de Sistemes i Automàtica | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada | es_ES |
dc.description.bibliographicCitation | Pardo García, N.; Montero Reguera, ÁE.; Sala Piqueras, A.; Martos Torres, J.; Urchueguía Schölzel, JF. (2011). Efficiency improvement of a ground coupled heat pump system from energy management. Applied Thermal Engineering. 31(2):391-398. https://doi.org/10.1016/j.applthermaleng.2010.09.016 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.applthermaleng.2010.09.016 | es_ES |
dc.description.upvformatpinicio | 391 | es_ES |
dc.description.upvformatpfin | 398 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 31 | es_ES |
dc.description.issue | 2 | es_ES |
dc.relation.senia | 38856 | |
dc.identifier.eissn | 1873-5606 | |
dc.contributor.funder | Ministerio de Ciencia e Innovación | es_ES |
dc.contributor.funder | Generalitat Valenciana | es_ES |
dc.contributor.funder | Ministerio de Educación y Ciencia |