Mismatches between objective parameters and measured perception assessment in room acoustics: a holistic approach

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Mismatches between objective parameters and measured perception assessment in room acoustics: a holistic approach

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Giménez Pérez, Alicia es_ES
dc.contributor.author Cibrián Ortíz de Anda, Rosa es_ES
dc.contributor.author Cerdá Jordá, Salvador es_ES
dc.contributor.author Girón, Sara es_ES
dc.contributor.author Zamarreño García, Teófilo es_ES
dc.date.accessioned 2015-03-11T11:28:43Z
dc.date.available 2015-03-11T11:28:43Z
dc.date.issued 2014-04
dc.identifier.issn 0360-1323
dc.identifier.uri http://hdl.handle.net/10251/47986
dc.description.abstract Psychoacoustic research in the field of concert halls has revealed that many aspects concerning listening perception have yet to be totally understood. On the one hand, the objective room acoustics of performance spaces are reflected in parameters, some standardized and some not, but these are related to a limited number of perceptual attributes of human response. In general, these objective parameters cannot accurately describe the acoustic details due to their inherent simplification. Under these premises, impulse responses (576 receivers) are measured in 16 concert halls, according to standard procedures, and the perception and satisfaction of the occupants of the rooms are evaluated by completing a questionnaire during live concerts. Correlation analyses and multidimensional scaling (MDS) techniques have been applied to spatial and multi-band averaged values of the acoustic parameters studied (18), and the average values of users responses (1284) to the questionnaire items (26). As a first result, correlations between objective parameters and users responses show that transversality exists between them. Secondly, hierarchical clustering produces the classification of survey questions in 7 hierarchical classes. On the other hand, a lack of tuning between objective parameters and perceptual responses is observed on applying MDS analysis to the ordination of the venues from a subjective assessment and a subjectiveobjective assessment. Finally, although the results show the mismatch between objective parameters and subjective responses, a model of subjective global evaluation of the acoustics of the room from data of three orthogonal acoustic parameters is implemented, revealing a reasonably good fit. es_ES
dc.description.sponsorship The authors wish to express their gratitude to P. Bustamante for his help, to all those who participated as listeners in this study, and to management and staff of each hall for facilitating acoustic measurements and allowing distribution of the questionnaires in their theatres. This work has been financially supported by FEDER funds and by the Ministry of Science and Technology with references Nos. BIA2003-09306, BIA2008-05485, BIA 2010-20523, and BIA 2012-36896. en_EN
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Building and Environment es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Perceptive acoustic evaluation es_ES
dc.subject Room acoustics es_ES
dc.subject Concert hall es_ES
dc.subject Multidimensional scaling es_ES
dc.subject Acoustic quality es_ES
dc.subject Concert-goers responses es_ES
dc.subject.classification MATEMATICA APLICADA es_ES
dc.subject.classification FISICA APLICADA es_ES
dc.title Mismatches between objective parameters and measured perception assessment in room acoustics: a holistic approach es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.buildenv.2013.12.022
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//BIA2008-05485/ES/ESTUDIO DE PARAMETROS OBJETIVOS Y SUBJETIVOS EVALUADORES DE LA CALIDAD ACUSTICA PERCIBIDA EN SALAS, AUDITORIOS Y EDIFICIOS DEL PATRIMONIO HISTORICO-ARTISTICO. VALIDACION DE UN PROTOCOLO DE CALIDAD ACU/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICYT//BIA2003-09306-C04-01/ES/Establecimiento de parámetros acústicos determinantes de la calidad percibida en salas de conciertos y auditorios. Propuesta para su aplicación en los proyectos de nueva planta o rehabilitación/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//BIA2010-20523/ES/LA ACUSTICA DE LAS CATEDRALES: UNA APORTACION CIENTIFICA PARA LA RECUPERACION DEL PATRIMONIO CULTURAL/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//BIA2012-36896/ES/ACUSTICA VIRTUAL.APLICACION DEL PROTOCOLO DE CALIDAD ACUSTICA CON RV, EN PROYECTOS DE DISEÑO, REHABILITACION Y EN ACUSTICA ARQUEOLOGICA DEL PATRIMONIO MATERIAL/INMATERIAL/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Matemática Aplicada - Departament de Matemàtica Aplicada es_ES
dc.description.bibliographicCitation Giménez Pérez, A.; Cibrián Ortíz De Anda, R.; Cerdá Jordá, S.; Girón, S.; Zamarreño García, T. (2014). Mismatches between objective parameters and measured perception assessment in room acoustics: a holistic approach. Building and Environment. 74:119-131. doi:10.1016/j.buildenv.2013.12.022 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1016/j.buildenv.2013.12.022 es_ES
dc.description.upvformatpinicio 119 es_ES
dc.description.upvformatpfin 131 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 74 es_ES
dc.relation.senia 254511
dc.identifier.eissn 1873-684X


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem