Mostrar el registro sencillo del ítem
dc.contributor.author | Rey Tormos, Romina María del | es_ES |
dc.contributor.author | Alba Fernández, Jesús | es_ES |
dc.contributor.author | Arenas, Jorge P. | es_ES |
dc.contributor.author | Ramis Soriano, Jaime | es_ES |
dc.date.accessioned | 2015-03-12T12:24:14Z | |
dc.date.available | 2015-03-12T12:24:14Z | |
dc.date.issued | 2013 | |
dc.identifier.issn | 0137-5075 | |
dc.identifier.uri | http://hdl.handle.net/10251/48024 | |
dc.description.abstract | [EN] It is well known that sound absorption and sound transmission properties of open porous materials are highly dependent on their airflow resistance values. Low values of airflow resistance indicate little resistance for air streaming through the porous material and high values are a sign that most of the pores inside the material are closed. The laboratory procedures for measuring airflow resistance have been stan- dardized by several organizations, including ISO and ASTM for both alternate flow and continuous flow. However, practical implementation of these standardized methods could be both complex and expensive. In this work, two indirect alternative measurement procedures were compared against the alternate flow standardized technique. The techniques were tested using three families of eco-friendly sound absorbent materials: recycled polyurethane foams, coconut natural fibres, and recycled polyester fibres. It is found that the values of airflow resistance measured using both alternative methods are very similar. There is also a good correlation between the values obtained through alternative and standardized methods. | es_ES |
dc.description.sponsorship | This project has been made possible thanks to the FONDECYT Project 1110605 and the grant GV/2012/066 Projects I+D for emerging research groups. The authors would like to thank Dr. Luis Godinho from the Department of Civil Engineering of University of Coimbra (Portugal) for his help with the experimental work and the ISO data reported in Table 1 of this paper. | |
dc.language | Inglés | es_ES |
dc.publisher | Polish Scientific Publishers | es_ES |
dc.relation.ispartof | Archives of Acoustics | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Material characterization | es_ES |
dc.subject | Airflow resistance | es_ES |
dc.subject | Sound absorbing materials | es_ES |
dc.subject | Eco-friendly materials | es_ES |
dc.subject.classification | FISICA APLICADA | es_ES |
dc.title | Evaluation of two alternative procedures for measuring airflow resistance of sound absorbing materials | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.2478/aoa:2013-0064 | |
dc.relation.projectID | info:eu-repo/grantAgreement/FONDECYT//1110605/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//GV%2F2012%2F066/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Investigación para la Gestión Integral de Zonas Costeras - Institut d'Investigació per a la Gestió Integral de Zones Costaneres | es_ES |
dc.description.bibliographicCitation | Rey Tormos, RMD.; Alba Fernández, J.; Arenas, JP.; Ramis Soriano, J. (2013). Evaluation of two alternative procedures for measuring airflow resistance of sound absorbing materials. Archives of Acoustics. 38(4):547-554. https://doi.org/10.2478/aoa:2013-0064 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.2478/aoa-2013-0064 | es_ES |
dc.description.upvformatpinicio | 547 | es_ES |
dc.description.upvformatpfin | 554 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 38 | es_ES |
dc.description.issue | 4 | es_ES |
dc.relation.senia | 254218 | |
dc.contributor.funder | Fondo Nacional de Desarrollo Científico y Tecnológico, Chile | |
dc.contributor.funder | Generalitat Valenciana |