Uncertainty and sensitivity analysis of the effect of the mean energy and FWHM of the initial electron fluence on the Bremsstrahlung photon spectra of linear accelerators

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Uncertainty and sensitivity analysis of the effect of the mean energy and FWHM of the initial electron fluence on the Bremsstrahlung photon spectra of linear accelerators

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Juste Vidal, Belen Jeanine es_ES
dc.contributor.author Miró Herrero, Rafael es_ES
dc.contributor.author Verdú Martín, Gumersindo Jesús es_ES
dc.contributor.author Macian, R.
dc.date.accessioned 2015-04-09T17:34:54Z
dc.date.available 2015-04-09T17:34:54Z
dc.date.issued 2012-07
dc.identifier.issn 0969-8043
dc.identifier.uri http://hdl.handle.net/10251/48740
dc.description.abstract A calculation of the correct dose in radiation therapy requires an accurate description of the radiation source because uncertainties in characterization of the linac photon spectrum are propagated through the dose calculations. Unfortunately, detailed knowledge of the initial electron beam parameters is not readily available, and many researchers adjust the initial electron fluence values by trial-and-error methods. The main goal of this work was to develop a methodology to characterize the fluence of initial electrons before they hit the tungsten target of an Elekta Precise medical linear accelerator. To this end, we used a Monte Carlo technique to analyze the influence of the characteristics of the initial electron beam on the distribution of absorbed dose from a 6 MV linac photon beam in a water phantom. The technique is based on calculations with Software for Uncertainty and Sensitivity Analysis (SUSA) and Monte Carlo simulations with the MCNP5 transport code. The free parameters used in the SUSA calculations were the mean energy and full-width-at-half-maximum (FWHM) of the initial electron distribution. A total of 93 combinations of these parameters gave initial electron fluence configurations. The electron spectra thus obtained were used in a simulation of the electron transport through the target of the linear accelerator, which produced different photon (Bremsstrahlung) spectra. The simulated photon spectra were compared with the 6-MV photon spectrum provided by the linac manufacturer (Elekta). This comparison revealed how the mean energy and FWHM of the initial electron fluence affect the spectrum of the generated photons. This study has made it possible to fine-tune the examined electron beam parameters to obtain the resulted absorbed doses with acceptable accuracy (error < 1%). (C) 2012 Elsevier Ltd. All rights reserved. es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Applied Radiation and Isotopes es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Uncertainty and sensitivity analysis es_ES
dc.subject Monte Carlo methods es_ES
dc.subject MCNP5 es_ES
dc.subject Elekta radiotherapy linac es_ES
dc.subject Electron spectrum es_ES
dc.subject.classification INGENIERIA NUCLEAR es_ES
dc.title Uncertainty and sensitivity analysis of the effect of the mean energy and FWHM of the initial electron fluence on the Bremsstrahlung photon spectra of linear accelerators es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.apradiso.2012.03.040
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Química y Nuclear - Departament d'Enginyeria Química i Nuclear es_ES
dc.description.bibliographicCitation Juste Vidal, BJ.; Miró Herrero, R.; Verdú Martín, GJ.; Macian, R. (2012). Uncertainty and sensitivity analysis of the effect of the mean energy and FWHM of the initial electron fluence on the Bremsstrahlung photon spectra of linear accelerators. Applied Radiation and Isotopes. 70(7):1267-1271. doi:10.1016/j.apradiso.2012.03.040 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1016/j.apradiso.2012.03.040 es_ES
dc.description.upvformatpinicio 1267 es_ES
dc.description.upvformatpfin 1271 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 70 es_ES
dc.description.issue 7 es_ES
dc.relation.senia 231045


Este ítem aparece en la(s) siguiente(s) colección(ones)