Mostrar el registro sencillo del ítem
dc.contributor.author | Ortega, Rubén | es_ES |
dc.contributor.author | Figueres Amorós, Emilio | es_ES |
dc.contributor.author | Garcerá Sanfeliú, Gabriel | es_ES |
dc.contributor.author | Trujillo Rodríguez, César Leonardo | es_ES |
dc.contributor.author | Velasco de la Fuente, David | es_ES |
dc.date.accessioned | 2015-04-15T11:43:49Z | |
dc.date.available | 2015-04-15T11:43:49Z | |
dc.date.issued | 2012-04 | |
dc.identifier.issn | 1364-0321 | |
dc.identifier.uri | http://hdl.handle.net/10251/48855 | |
dc.description.abstract | [EN] This paper presents the design, analysis and implementation of four control techniques (proportional-integral, two-degree of freedom, repetitive and resonant) with the aim of reducing the total harmonic distortion in voltage (THDv). When the inverter is working as a voltage source theses techniques are useful in island mode operation. The purpose is to keep the output voltage waveform, frequency and amplitude according to the standard IEEE 519, when nonlinear loads are fed. A comparative analysis derived from inverter simulations with nonlinear loads is realized in order to validate those control techniques. (C) 2011 Elsevier Ltd. All rights reserved. | es_ES |
dc.description.sponsorship | This work was supported by the Spanish Ministry of Science and Innovation under Grant ENE2009-13998-C02-02. The first author thanks the support of the Instituto Politecnico Nacional (IPN), the Comision de Operacion y Fomento de Actividades Academicas (COFAA), the Secretaria de Educacion Publica and the Agencia Espanola de Cooperacion Internacional para el Desarrollo (AECID). | |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Renewable and Sustainable Energy Reviews | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Two-degree of freedom controller | es_ES |
dc.subject | Repetitive controller | es_ES |
dc.subject | Resonant controller Inverter | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.title | Control techniques for reduction of the total harmonic distortion in voltage applied to a single-phase inverter with nonlinear loads: Review | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.rser.2011.11.027 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//ENE2009-13998-C02-02/ES/Estructuras Flexibles De Control De Convertidores Electronicos Para Procesado E Integracion De Energias Renovables En Microrredes/ | es_ES |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Grupo de Sistemas Electrónicos Industriales | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica | es_ES |
dc.description.bibliographicCitation | Ortega, R.; Figueres Amorós, E.; Garcerá Sanfeliú, G.; Trujillo Rodríguez, CL.; Velasco De La Fuente, D. (2012). Control techniques for reduction of the total harmonic distortion in voltage applied to a single-phase inverter with nonlinear loads: Review. Renewable and Sustainable Energy Reviews. 16(3):1754-1761. https://doi.org/10.1016/j.rser.2011.11.027 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.rser.2011.11.027 | es_ES |
dc.description.upvformatpinicio | 1754 | es_ES |
dc.description.upvformatpfin | 1761 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 16 | es_ES |
dc.description.issue | 3 | es_ES |
dc.relation.senia | 233661 | |
dc.contributor.funder | Ministerio de Ciencia e Innovación |