Results of a combined monolithic crystal and an array of ASICs controlled SiPMs

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Results of a combined monolithic crystal and an array of ASICs controlled SiPMs

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Conde Castellanos, Pablo Eloy es_ES
dc.contributor.author González Martínez, Antonio Javier es_ES
dc.contributor.author Hernández Hernández, Liczandro es_ES
dc.contributor.author Bellido, P. es_ES
dc.contributor.author Iborra Carreres, Amadeo es_ES
dc.contributor.author Crespo Navarro, Efren es_ES
dc.contributor.author Moliner Martínez, Laura es_ES
dc.contributor.author Rigla, JP. es_ES
dc.contributor.author Rodríguez Álvarez, María José es_ES
dc.contributor.author Sánchez, F. es_ES
dc.contributor.author Seimetz, Michael es_ES
dc.contributor.author Soriano Asensi, Antonio es_ES
dc.contributor.author Vidal San Sebastián, Luis Fernando es_ES
dc.contributor.author Benlloch Baviera, Jose María es_ES
dc.date.accessioned 2015-04-27T07:22:33Z
dc.date.available 2015-04-27T07:22:33Z
dc.date.issued 2014-01
dc.identifier.issn 0168-9002
dc.identifier.uri http://hdl.handle.net/10251/49277
dc.description.abstract [EN] In this work we present the energy and spatial resolutions we have obtained for a γ ray detector based on a monolithic LYSO crystal coupled to an array of 256 SiPMs. Two crystal configurations of the same trapezoidal shape have been tried. In one approach all surfaces were black painted but the exit one facing the photosensor array which was polished. The other approach included a retroreflector (RR) layer coupled to the entrance face of the crystal powering the amount of transmitted light to the photosensors. Two coupling media between the scintillator and the SiPM array were used, namely direct coupling by means of optical grease and coupling through an array of light guides. Since the same operational voltage was supplied to the entire array, it was needed to equalize their gains before feeding their signals to the Data Acquisition system. Such a job was performed by means of 4 scalable Application Specific Circuits (ASICs). An energy resolution of about 24.4% has been achieved for the direct coupling with the RR layer together with a spatial resolution of approximately 2.9 mm at the detector center. With the light guides coupling the effects of image compression at the edges are significantly minimized, but worsening the energy resolution to about 33.1% with a spatial resolution nearing 4 mm at the detector center. & 2013 Elsevier B.V. All rights reserved. es_ES
dc.description.sponsorship cknowledgments This work was supported by the Centre for Industrial Technological Development co-funded by FEDER through the Technology Fund (DREAM Project, IDI-20110718), the Spanish Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica (IþDþI) under Grant no. FIS2010-21216-CO2-01 and the Valencian Local Government under Grant PROMETEO 2008/114
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Monolithic crystals es_ES
dc.subject SiPMs es_ES
dc.subject ASIC es_ES
dc.subject.classification MATEMATICA APLICADA es_ES
dc.title Results of a combined monolithic crystal and an array of ASICs controlled SiPMs es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.nima.2013.08.079
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//IDI-20110718/ES/INVESTIGACIÓN EN DETECCIÓN PARA APLICACIONES DE SALUD MENTAL (1%2F3)/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//FIS2010-21216-C02-01/ES/DESARROLLO DEL DETECTOR PET%2FRM PARA DIAGNOSTICO DE ENFERMEDADES NEURODEGENERATIVAS./ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//PROMETEO08%2F2008%2F114/ES/Desarrollo de tecnología PET%2FRM para estudio cerebro en humanos/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Matemática Aplicada - Departament de Matemàtica Aplicada es_ES
dc.description.bibliographicCitation Conde Castellanos, PE.; González Martínez, AJ.; Hernández Hernández, L.; Bellido, P.; Iborra Carreres, A.; Crespo Navarro, E.; Moliner Martínez, L.... (2014). Results of a combined monolithic crystal and an array of ASICs controlled SiPMs. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 734:132-136. https://doi.org/10.1016/j.nima.2013.08.079 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1016/j.nima.2013.08.079 es_ES
dc.description.upvformatpinicio 132 es_ES
dc.description.upvformatpfin 136 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 734 es_ES
dc.relation.senia 252250
dc.contributor.funder European Regional Development Fund
dc.contributor.funder Generalitat Valenciana
dc.contributor.funder Ministerio de Ciencia e Innovación
dc.contributor.funder Centro para el Desarrollo Tecnológico Industrial es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)