Mostrar el registro sencillo del ítem
dc.contributor.author | Conde Castellanos, Pablo Eloy | es_ES |
dc.contributor.author | González Martínez, Antonio Javier | es_ES |
dc.contributor.author | Hernández Hernández, Liczandro | es_ES |
dc.contributor.author | Bellido, P. | es_ES |
dc.contributor.author | Iborra Carreres, Amadeo | es_ES |
dc.contributor.author | Crespo Navarro, Efren | es_ES |
dc.contributor.author | Moliner Martínez, Laura | es_ES |
dc.contributor.author | Rigla, JP. | es_ES |
dc.contributor.author | Rodríguez Álvarez, María José | es_ES |
dc.contributor.author | Sánchez, F. | es_ES |
dc.contributor.author | Seimetz, Michael | es_ES |
dc.contributor.author | Soriano Asensi, Antonio | es_ES |
dc.contributor.author | Vidal San Sebastián, Luis Fernando | es_ES |
dc.contributor.author | Benlloch Baviera, Jose María | es_ES |
dc.date.accessioned | 2015-04-27T07:22:33Z | |
dc.date.available | 2015-04-27T07:22:33Z | |
dc.date.issued | 2014-01 | |
dc.identifier.issn | 0168-9002 | |
dc.identifier.uri | http://hdl.handle.net/10251/49277 | |
dc.description.abstract | [EN] In this work we present the energy and spatial resolutions we have obtained for a γ ray detector based on a monolithic LYSO crystal coupled to an array of 256 SiPMs. Two crystal configurations of the same trapezoidal shape have been tried. In one approach all surfaces were black painted but the exit one facing the photosensor array which was polished. The other approach included a retroreflector (RR) layer coupled to the entrance face of the crystal powering the amount of transmitted light to the photosensors. Two coupling media between the scintillator and the SiPM array were used, namely direct coupling by means of optical grease and coupling through an array of light guides. Since the same operational voltage was supplied to the entire array, it was needed to equalize their gains before feeding their signals to the Data Acquisition system. Such a job was performed by means of 4 scalable Application Specific Circuits (ASICs). An energy resolution of about 24.4% has been achieved for the direct coupling with the RR layer together with a spatial resolution of approximately 2.9 mm at the detector center. With the light guides coupling the effects of image compression at the edges are significantly minimized, but worsening the energy resolution to about 33.1% with a spatial resolution nearing 4 mm at the detector center. & 2013 Elsevier B.V. All rights reserved. | es_ES |
dc.description.sponsorship | cknowledgments This work was supported by the Centre for Industrial Technological Development co-funded by FEDER through the Technology Fund (DREAM Project, IDI-20110718), the Spanish Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica (IþDþI) under Grant no. FIS2010-21216-CO2-01 and the Valencian Local Government under Grant PROMETEO 2008/114 | |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Monolithic crystals | es_ES |
dc.subject | SiPMs | es_ES |
dc.subject | ASIC | es_ES |
dc.subject.classification | MATEMATICA APLICADA | es_ES |
dc.title | Results of a combined monolithic crystal and an array of ASICs controlled SiPMs | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.nima.2013.08.079 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//IDI-20110718/ES/INVESTIGACIÓN EN DETECCIÓN PARA APLICACIONES DE SALUD MENTAL (1%2F3)/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//FIS2010-21216-C02-01/ES/DESARROLLO DEL DETECTOR PET%2FRM PARA DIAGNOSTICO DE ENFERMEDADES NEURODEGENERATIVAS./ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//PROMETEO08%2F2008%2F114/ES/Desarrollo de tecnología PET%2FRM para estudio cerebro en humanos/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Matemática Aplicada - Departament de Matemàtica Aplicada | es_ES |
dc.description.bibliographicCitation | Conde Castellanos, PE.; González Martínez, AJ.; Hernández Hernández, L.; Bellido, P.; Iborra Carreres, A.; Crespo Navarro, E.; Moliner Martínez, L.... (2014). Results of a combined monolithic crystal and an array of ASICs controlled SiPMs. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 734:132-136. https://doi.org/10.1016/j.nima.2013.08.079 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.nima.2013.08.079 | es_ES |
dc.description.upvformatpinicio | 132 | es_ES |
dc.description.upvformatpfin | 136 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 734 | es_ES |
dc.relation.senia | 252250 | |
dc.contributor.funder | European Regional Development Fund | |
dc.contributor.funder | Generalitat Valenciana | |
dc.contributor.funder | Ministerio de Ciencia e Innovación | |
dc.contributor.funder | Centro para el Desarrollo Tecnológico Industrial | es_ES |