Mostrar el registro sencillo del ítem
dc.contributor.author | Catalá Icardo, Mónica | es_ES |
dc.contributor.author | López Paz, José Luis | es_ES |
dc.contributor.author | Peña Badenas, Andrea | es_ES |
dc.date.accessioned | 2015-04-28T06:56:57Z | |
dc.date.available | 2015-04-28T06:56:57Z | |
dc.date.issued | 2011 | |
dc.identifier.issn | 0910-6340 | |
dc.identifier.uri | http://hdl.handle.net/10251/49337 | |
dc.description.abstract | [EN] A new method for the determination of the herbicide diuron, using a flow injection manifold and photoinduced chemiluminescence detection, is presented. The pesticide, in basic medium, was irradiated on-line with UV light (254 nm) for 53 s. A short discussion about the possible irradiation products is included. The chemiluminescent response of the photoproducts was induced by oxidation with potassium ferricyanide in phosphate buffer at pH 11.5. The method permitted the quantification of diuron over the 0.1 – 4.0 mg L–1 range, with a detection limit (S/N = 3) of 20 μg L–1 when the method was applied directly. However, the use of solid phase extraction (SPE) performed with C18 cartridges allowed us to achieve a limit of detection of 0.4 μg L–1 and a 1.5 – 30 μg L–1 dynamic range. The method was successfully applied to the diuron determination in samples of water from different sources (spring, ground, mineral, irrigation, sea and tap waters) with a low consumption of reagents. | es_ES |
dc.description.sponsorship | The authors would like to thank the Ministry of Education and Science of Spain for financial support: Project CTM2006-11991 and FEDER funds. | |
dc.language | Inglés | es_ES |
dc.publisher | Japan Society for Analytical Chemistry | es_ES |
dc.relation.ispartof | Analytical Sciences | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | FI-photoinduced Chemiluminescence Method | es_ES |
dc.subject | Herbicide diuron | es_ES |
dc.subject.classification | QUIMICA ANALITICA | es_ES |
dc.title | FI-photoinduced Chemiluminescence Method for Diuron Determination in Water Samples | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.2116/analsci.27.291 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MEC//CTM2006-11991/ES/DESARROLLO DE METODOS SENCILLOS EN FLUJO CONTINUO CON DETECCION QUIMIOLUMINISCENTE APLICADOS AL CONTROL DE PLAGUICIDAS EN LOS CULTIVOS DE CITRICOS/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Química - Departament de Química | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Investigación para la Gestión Integral de Zonas Costeras - Institut d'Investigació per a la Gestió Integral de Zones Costaneres | es_ES |
dc.description.bibliographicCitation | Catalá Icardo, M.; López Paz, JL.; Peña Badenas, A. (2011). FI-photoinduced Chemiluminescence Method for Diuron Determination in Water Samples. Analytical Sciences. 27(3):291-296. https://doi.org/10.2116/analsci.27.291 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | https://doi.org/10.2116/analsci.27.291 | es_ES |
dc.description.upvformatpinicio | 291 | es_ES |
dc.description.upvformatpfin | 296 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 27 | es_ES |
dc.description.issue | 3 | es_ES |
dc.relation.senia | 193974 | |
dc.identifier.pmid | 21415512 | |
dc.contributor.funder | Ministerio de Educación y Ciencia |