Mostrar el registro sencillo del ítem
dc.contributor.author | Aguado López, José Vicente | es_ES |
dc.contributor.author | Espinós Capilla, Ana | es_ES |
dc.contributor.author | Hospitaler Pérez, Antonio | es_ES |
dc.contributor.author | Ortega, J. | es_ES |
dc.contributor.author | Romero, Manuel L. | es_ES |
dc.date.accessioned | 2015-05-05T09:40:23Z | |
dc.date.available | 2015-05-05T09:40:23Z | |
dc.date.issued | 2012-10 | |
dc.identifier.issn | 0379-7112 | |
dc.identifier.uri | http://hdl.handle.net/10251/49684 | |
dc.description.abstract | [EN] This paper describes standard scale fire tests conducted on four precast prestressed hollow core slabs configurations under flexure. The influence of the reinforcement arrangement was investigated using two test parameters: the average axis distance (from 30.1 to 46.7 mm), and the type of reinforcement (5 mm diameter wires and 9.5 mm diameter strands). An ISO 834 standard fire was applied maintaining the load level in a four-point test arrangement constant. The results presented different failure mechanisms, types of cracks, spalling patterns, and fire resistance ratings and it was shown that wires displayed optimal behavior as opposed to strands. A comparison was carried out with the current verification methods provided in Eurocode 2 part 12, and showed that verification methods tend to overestimate the calculation of fire resistance when both wire and strands are moved away from the exposed surface. | es_ES |
dc.description.sponsorship | The authors wish to express their sincere gratitude to the Generalitat Valenciana for help provided through project FIRESTRUCT 1. | |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Fire Safety Journal | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Fire resistance | es_ES |
dc.subject | Hollow core slabs | es_ES |
dc.subject | Precast construction | es_ES |
dc.subject | Reinforcement | es_ES |
dc.subject.classification | MECANICA DE LOS MEDIOS CONTINUOS Y TEORIA DE ESTRUCTURAS | es_ES |
dc.subject.classification | INGENIERIA DE LA CONSTRUCCION | es_ES |
dc.title | Influence of reinforcement arrangement in flexural fire behavior of hollow core slabs | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.firesaf.2012.06.015 | |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Ciencia y Tecnología del Hormigón - Institut de Ciència i Tecnologia del Formigó | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Mecánica de los Medios Continuos y Teoría de Estructuras - Departament de Mecànica dels Medis Continus i Teoria d'Estructures | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería de la Construcción y de Proyectos de Ingeniería Civil - Departament d'Enginyeria de la Construcció i de Projectes d'Enginyeria Civil | es_ES |
dc.description.bibliographicCitation | Aguado López, JV.; Espinós Capilla, A.; Hospitaler Pérez, A.; Ortega, J.; Romero, ML. (2012). Influence of reinforcement arrangement in flexural fire behavior of hollow core slabs. Fire Safety Journal. 53:72-84. doi:10.1016/j.firesaf.2012.06.015 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.firesaf.2012.06.015 | es_ES |
dc.description.upvformatpinicio | 72 | es_ES |
dc.description.upvformatpfin | 84 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 53 | es_ES |
dc.relation.senia | 223796 | |
dc.contributor.funder | Generalitat Valenciana |