- -

Fire behavior of axially loaded slender high strength concrete-filled tubular columns

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Fire behavior of axially loaded slender high strength concrete-filled tubular columns

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Romero, Manuel L. es_ES
dc.contributor.author Moliner, V. es_ES
dc.contributor.author Espinós Capilla, Ana es_ES
dc.contributor.author Ibáñez Usach, Carmen es_ES
dc.contributor.author Hospitaler Pérez, Antonio es_ES
dc.date.accessioned 2015-05-05T12:23:59Z
dc.date.available 2015-05-05T12:23:59Z
dc.date.issued 2011-12
dc.identifier.issn 0143-974X
dc.identifier.uri http://hdl.handle.net/10251/49696
dc.description.abstract This paper describes sixteen fire tests conducted on slender circular hollow section columns filled with normal and high strength concrete, subjected to concentric axial loads. The test parameters were the nominal strength of concrete (30 and 80 MPa), the infilling type (plain concrete, reinforced concrete and steel fiber reinforced concrete) and the axial load level (20% and 40%). The columns were tested under fixed-pinned boundary conditions and the relative slenderness at room temperature was higher than 0.5 in all of the cases. A numerical model was validated against the tests, in order to extend the results and understand the failure mode of such columns. It is the aim of this paper to study the influence in a fire situation of the use of high strength concrete, as opposed to normal strength concrete. The results have shown that for slender columns subjected to high temperatures, the behavior of high strength concrete was different than for stub columns, spalling not being observed in the experiments. Furthermore, the addition of steel fibers was not found very advantageous in slender columns, since no increment in terms of fire resistance was obtained for the columns which used this type of reinforcement. However, the addition of reinforcing bars seems to be the solution in some cases, where the use of external fire protection wants to be avoided in the design of HSS structures, since the reinforcing bars allow the tube to resist a higher axial load es_ES
dc.description.sponsorship The authors wish to express their sincere gratitude to the Spanish Ministry of Science and Innovation for help provided through project BIA 2009_09411, and to the European Community for the FEDER funds. en_EN
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Journal of Constructional Steel Research es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Fire resistance es_ES
dc.subject Composite column es_ES
dc.subject Concrete-filled tubular column es_ES
dc.subject High strength concrete es_ES
dc.subject.classification MECANICA DE LOS MEDIOS CONTINUOS Y TEORIA DE ESTRUCTURAS es_ES
dc.subject.classification INGENIERIA DE LA CONSTRUCCION es_ES
dc.title Fire behavior of axially loaded slender high strength concrete-filled tubular columns es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.jcsr.2011.06.012
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//BIA2009-09411/ES/Comportamiento Resistente Frente A Altas Temperaturas De Perfiles Tubulares De Acero Rellenos De Hormigon De Alta Resistencia/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Ciencia y Tecnología del Hormigón - Institut de Ciència i Tecnologia del Formigó es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Mecánica de los Medios Continuos y Teoría de Estructuras - Departament de Mecànica dels Medis Continus i Teoria d'Estructures es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería de la Construcción y de Proyectos de Ingeniería Civil - Departament d'Enginyeria de la Construcció i de Projectes d'Enginyeria Civil es_ES
dc.description.bibliographicCitation Romero, ML.; Moliner, V.; Espinós Capilla, A.; Ibáñez Usach, C.; Hospitaler Pérez, A. (2011). Fire behavior of axially loaded slender high strength concrete-filled tubular columns. Journal of Constructional Steel Research. 67(12):1953-1965. https://doi.org/10.1016/j.jcsr.2011.06.012 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1016/j.jcsr.2011.06.012 es_ES
dc.description.upvformatpinicio 1953 es_ES
dc.description.upvformatpfin 1965 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 67 es_ES
dc.description.issue 12 es_ES
dc.relation.senia 202194
dc.contributor.funder Ministerio de Ciencia e Innovación es_ES
dc.contributor.funder European Regional Development Fund es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem