Mostrar el registro sencillo del ítem
dc.contributor.author | López Paz, José Luis | es_ES |
dc.contributor.author | Catalá Icardo, Mónica | es_ES |
dc.contributor.author | Langa Sánchez, Adrián | es_ES |
dc.date.accessioned | 2015-06-04T11:52:20Z | |
dc.date.available | 2015-06-04T11:52:20Z | |
dc.date.issued | 2014-02-13 | |
dc.identifier.issn | 0306-7319 | |
dc.identifier.uri | http://hdl.handle.net/10251/51251 | |
dc.description.abstract | A sensitive, economic, rapid and simple method for the determination of four N-methylcarbamate pesticides: methomyl (2.0–80 μg L−1), aldicarb (5.0–50 μg L−1), butocarboxim (2.0–60 μg L−1) and oxamyl (2.0–60 μg L−1); is reported. It relies on the coupling of photoinduced chemiluminescence (PICL) detection with flow injection (FI) methodology. The automation of FI together with the use of light as a reagent decreased the environmental impact of the analysis. The proposed method was based on the oxidation of these pesticides, previously irradiated on-line with UV light, with cerium(IV), using quinine as a sensitiser. Limits of detection below the legal limits (100 ng L−1) established by the European Union for drinking waters were obtained without the need of preconcentration steps. A good inter-day reproducibility (1.6–6.4%, n = 5), repeatability (rsd = 2.7 %, n = 25) and high throughput (123 h−1) were achieved. The method was successfully applied to the determination of methomyl in natural waters with mean recoveries ranging from 90% to 98%. | es_ES |
dc.description.sponsorship | The authors would like to thank Ministerio de Educacion y Ciencia from Spain and FEDER funds for financial support: Project CTM2006-11991. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | Taylor & Francis: STM, Behavioural Science and Public Health Titles | es_ES |
dc.relation.ispartof | International Journal of Environmental Analytical Chemistry | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Flow injection | es_ES |
dc.subject | N-methylcarbamates | es_ES |
dc.subject | Photoinduced chemiluminescence | es_ES |
dc.subject | Pesticides | es_ES |
dc.subject | Water | es_ES |
dc.subject.classification | QUIMICA ANALITICA | es_ES |
dc.title | Determination of N-methylcarbamate pesticides using flow injection with photoinduced chemiluminescence detection | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1080/03067319.2013.879295 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MEC//CTM2006-11991/ES/DESARROLLO DE METODOS SENCILLOS EN FLUJO CONTINUO CON DETECCION QUIMIOLUMINISCENTE APLICADOS AL CONTROL DE PLAGUICIDAS EN LOS CULTIVOS DE CITRICOS/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Química - Departament de Química | es_ES |
dc.description.bibliographicCitation | López Paz, JL.; Catalá Icardo, M.; Langa Sánchez, A. (2014). Determination of N-methylcarbamate pesticides using flow injection with photoinduced chemiluminescence detection. International Journal of Environmental Analytical Chemistry. 94(6):606-617. https://doi.org/10.1080/03067319.2013.879295 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1080/03067319.2013.879295 | es_ES |
dc.description.upvformatpinicio | 606 | es_ES |
dc.description.upvformatpfin | 617 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 94 | es_ES |
dc.description.issue | 6 | es_ES |
dc.relation.senia | 269075 | |
dc.identifier.eissn | 1029-0397 | |
dc.contributor.funder | Ministerio de Educación y Ciencia | es_ES |
dc.description.references | Santaladchaiyakit, Y., Srijaranai, S., & Burakham, R. (2012). Methodological aspects of sample preparation for the determination of carbamate residues: A review. Journal of Separation Science, 35(18), 2373-2389. doi:10.1002/jssc.201200431 | es_ES |
dc.description.references | Fytianos, K., Pitarakis, K., & Bobola, E. (2006). Monitoring ofN-methylcarbamate pesticides in the Pinios River (central Greece) by HPLC. International Journal of Environmental Analytical Chemistry, 86(1-2), 131-145. doi:10.1080/03067310500248171 | es_ES |
dc.description.references | Moreno-González, D., Huertas-Pérez, J. F., Gámiz-Gracia, L., & García-Campaña, A. M. (2011). Determination of carbamates at trace levels in water and cucumber by capillary liquid chromatography. International Journal of Environmental Analytical Chemistry, 91(14), 1329-1340. doi:10.1080/03067319.2010.520127 | es_ES |
dc.description.references | Lambropoulou, D. A., & Albanis, T. A. (2007). Methods of sample preparation for determination of pesticide residues in food matrices by chromatography–mass spectrometry-based techniques: a review. Analytical and Bioanalytical Chemistry, 389(6), 1663-1683. doi:10.1007/s00216-007-1348-2 | es_ES |
dc.description.references | Trufelli, H., Palma, P., Famiglini, G., & Cappiello, A. (2010). An overview of matrix effects in liquid chromatography-mass spectrometry. Mass Spectrometry Reviews, 30(3), 491-509. doi:10.1002/mas.20298 | es_ES |
dc.description.references | Hernández-Borges, J., Frías-García, S., Cifuentes, A., & Rodríguez-Delgado, M. A. (2004). Pesticide analysis by capillary electrophoresis. Journal of Separation Science, 27(12), 947-963. doi:10.1002/jssc.200401820 | es_ES |
dc.description.references | Gámiz-Gracia, L., García-Campaña, A. M., Huertas-Pérez, J. F., & Lara, F. J. (2009). Chemiluminescence detection in liquid chromatography: Applications to clinical, pharmaceutical, environmental and food analysis—A review. Analytica Chimica Acta, 640(1-2), 7-28. doi:10.1016/j.aca.2009.03.017 | es_ES |
dc.description.references | Huertas-Pérez, J. F., & García-Campaña, A. M. (2008). Determination of N-methylcarbamate pesticides in water and vegetable samples by HPLC with post-column chemiluminescence detection using the luminol reaction. Analytica Chimica Acta, 630(2), 194-204. doi:10.1016/j.aca.2008.09.047 | es_ES |
dc.description.references | Pérez-Ruiz, T., Martínez-Lozano, C., & García, M. D. (2007). Determination of N-methylcarbamate pesticides in environmental samples by an automated solid-phase extraction and liquid chromatographic method based on post-column photolysis and chemiluminescence detection. Journal of Chromatography A, 1164(1-2), 174-180. doi:10.1016/j.chroma.2007.07.006 | es_ES |
dc.description.references | Orejuela, E., & Silva, M. (2003). Monitoring some phenoxyl-type N-methylcarbamate pesticide residues in fruit juices using high-performance liquid chromatography with peroxyoxalate-chemiluminescence detection. Journal of Chromatography A, 1007(1-2), 197-201. doi:10.1016/s0021-9673(03)00934-8 | es_ES |
dc.description.references | López-Paz, J. L., & Catalá-Icardo, M. (2011). Analysis of Pesticides by Flow Injection Coupled with Chemiluminescent Detection: A Review. Analytical Letters, 44(1-3), 146-175. doi:10.1080/00032719.2010.500788 | es_ES |
dc.description.references | WANG, X., LIN, J., LIU, M., & CHENG, X. (2009). Flow-based luminescence-sensing methods for environmental water analysis. TrAC Trends in Analytical Chemistry, 28(1), 75-87. doi:10.1016/j.trac.2008.10.005 | es_ES |
dc.description.references | Waseem, A., Yaqoob, M., Nabi, A., & Siddiqui, M. A. (2007). Determination of carbaryl by flow injection with luminol chemiluminescence inhibition detection. International Journal of Environmental Analytical Chemistry, 87(12), 825-832. doi:10.1080/03067310701380021 | es_ES |
dc.description.references | WASEEM, A., YAQOOB, M., & NABI, A. (2009). Photodegradation and Flow-Injection Determination of Dithiocarbamate Fungicides in Natural Water with Chemiluminescence Detection. Analytical Sciences, 25(3), 395-400. doi:10.2116/analsci.25.395 | es_ES |
dc.description.references | Torres-Cartas, S., Gómez-Benito, C., & Meseguer-Lloret, S. (2011). FI on-line chemiluminescence reaction for determination of MCPA in water samples. Analytical and Bioanalytical Chemistry, 402(3), 1289-1296. doi:10.1007/s00216-011-5567-1 | es_ES |
dc.description.references | Gómez-Benito, C., Meseguer-Lloret, S., & Torres-Cartas, S. (2013). Sensitive determination of Fenamiphos in water samples by flow injection photoinduced chemiluminescence. International Journal of Environmental Analytical Chemistry, 93(2), 152-165. doi:10.1080/03067319.2012.663755 | es_ES |
dc.description.references | Llorent-Martínez, E. J., Ortega-Barrales, P., Fernández-de Córdova, M. L., & Ruiz-Medina, A. (2011). Trends in flow-based analytical methods applied to pesticide detection: A review. Analytica Chimica Acta, 684(1-2), 30-39. doi:10.1016/j.aca.2010.10.036 | es_ES |
dc.description.references | Trojanowicz, M. (2012). Flow-injection analysis as a tool for determination of pharmaceutical residues in aqueous environment. Talanta, 96, 3-10. doi:10.1016/j.talanta.2011.12.081 | es_ES |
dc.description.references | Ibañez, G. A., & Escandar, G. M. (2011). Luminescence Sensors Applied to Water Analysis of Organic Pollutants—An Update. Sensors, 11(12), 11081-11102. doi:10.3390/s111211081 | es_ES |
dc.description.references | Lara, F. J., García-Campaña, A. M., & Aaron, J.-J. (2010). Analytical applications of photoinduced chemiluminescence in flow systems—A review. Analytica Chimica Acta, 679(1-2), 17-30. doi:10.1016/j.aca.2010.09.001 | es_ES |
dc.description.references | Icardo, M. C., & Calatayud, J. M. (2008). Photo-Induced Luminescence. Critical Reviews in Analytical Chemistry, 38(2), 118-130. doi:10.1080/10408340802039609 | es_ES |
dc.description.references | Van Scoy, A. R., Yue, M., Deng, X., & Tjeerdema, R. S. (2012). Environmental Fate and Toxicology of Methomyl. Reviews of Environmental Contamination and Toxicology, 93-109. doi:10.1007/978-1-4614-4717-7_3 | es_ES |
dc.description.references | RICART, I., ANTONFOS, G., DUART, M., MATEO, J., ZAMORA, L., & CALATAYUD, J. (2007). Theoretical prediction of the photoinduced chemiluminescence of pesticides. Talanta, 72(2), 378-386. doi:10.1016/j.talanta.2006.10.048 | es_ES |
dc.description.references | Freeman, P. K., & Ndip, E. M. N. (1984). Photochemistry of oxime carbamates. 2. Phototransformations of methomyl. Journal of Agricultural and Food Chemistry, 32(4), 877-881. doi:10.1021/jf00124a046 | es_ES |
dc.description.references | TAMIMI, M., QOURZAL, S., BARKA, N., ASSABBANE, A., & AITICHOU, Y. (2008). Methomyl degradation in aqueous solutions by Fenton’s reagent and the photo-Fenton system. Separation and Purification Technology, 61(1), 103-108. doi:10.1016/j.seppur.2007.09.017 | es_ES |
dc.description.references | Capitán-Vallvey, L. (2000). Chemiluminescence determination of sodium 2-mercaptoethane sulfonate by flow injection analysis using cerium(IV) sensitized by quinine. Talanta, 51(6), 1155-1161. doi:10.1016/s0039-9140(00)00291-5 | es_ES |
dc.description.references | NIE, L., MA, H., SUN, M., LI, X., SU, M., & LIANG, S. (2003). Direct chemiluminescence determination of cysteine in human serum using quinine–Ce(IV) system. Talanta, 59(5), 959-964. doi:10.1016/s0039-9140(02)00649-5 | es_ES |
dc.description.references | Lakowicz, J. R. (Ed.). (2006). Principles of Fluorescence Spectroscopy. doi:10.1007/978-0-387-46312-4 | es_ES |
dc.description.references | Vichapong, J., Burakham, R., Srijaranai, S., & Grudpan, K. (2011). Sequential injection-bead injection-lab-on-valve coupled to high-performance liquid chromatography for online renewable micro-solid-phase extraction of carbamate residues in food and environmental samples. Journal of Separation Science, 34(13), 1574-1581. doi:10.1002/jssc.201100075 | es_ES |
dc.description.references | Vichapong, J., & Burakham, R. (2012). Novel ultrasound-assisted mixed anionic–cationic surfactant-enhanced emulsification microextraction combined with HPLC for the determination of carbamate pesticides. Analytical Methods, 4(7), 2101. doi:10.1039/c2ay25139f | es_ES |
dc.description.references | Belmonte Vega, A., Garrido Frenich, A., & Martínez Vidal, J. L. (2005). Monitoring of pesticides in agricultural water and soil samples from Andalusia by liquid chromatography coupled to mass spectrometry. Analytica Chimica Acta, 538(1-2), 117-127. doi:10.1016/j.aca.2005.02.003 | es_ES |
dc.description.references | Gu, C., & Shamsi, S. A. (2010). CEC-atmospheric pressure ionization MS of pesticides using a surfactant-bound monolithic column. ELECTROPHORESIS, 31(7), 1162-1174. doi:10.1002/elps.200900739 | es_ES |
dc.description.references | Moreno-González, D., Gámiz-Gracia, L., Bosque-Sendra, J. M., & García-Campaña, A. M. (2012). Dispersive liquid–liquid microextraction using a low density extraction solvent for the determination of 17 N-methylcarbamates by micellar electrokinetic chromatography–electrospray–mass spectrometry employing a volatile surfactant. Journal of Chromatography A, 1247, 26-34. doi:10.1016/j.chroma.2012.05.048 | es_ES |
dc.description.references | European Union (98) Council Directive 98/83/EC of 3 November 1998 on the quality of water intended for human cosumption. Off. J. Eur. Commun. 41, 5.12.98, L 330/42. | es_ES |