Mostrar el registro completo del ítem
Cabello, R.; Sánchez, D.; Patiño, J.; Llopis, R.; Torrella Alcaraz, E. (2012). Experimental analysis of energy performance of modified single-stage CO2 transcritical vapour compression cycles based on vapour injection in the suction line. Applied Thermal Engineering. 47:86-94. https://doi.org/10.1016/j.applthermaleng.2012.02.031
Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/52402
Título: | Experimental analysis of energy performance of modified single-stage CO2 transcritical vapour compression cycles based on vapour injection in the suction line | |
Autor: | Cabello, Ramón Sánchez, Daniel Patiño, Jorge Llopis, Rodrigo Torrella Alcaraz, Enrique | |
Entidad UPV: |
|
|
Fecha difusión: |
|
|
Resumen: |
This work presents the experimental evaluation of the energy performance of a modified single-stage CO2 transcritical refrigeration plant with an internal heat exchanger (IHX) based on vapour injection in suction line. ...[+]
|
|
Palabras clave: |
|
|
Derechos de uso: | Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) | |
Fuente: |
|
|
DOI: |
|
|
Editorial: |
|
|
Versión del editor: | http://dx.doi.org/10.1016/j.applthermaleng.2012.02.031 | |
Código del Proyecto: |
|
|
Agradecimientos: |
The authors are indebted to the Spanish Ministry of Education and Science (CTM2008-06468-C02-02/TECNO) and to the Spanish Ministry of the Environment and Rural and Marine Affairs (200800050084716) for the economic support ...[+]
|
|
Tipo: |
|