dc.description.abstract | Most dental implant planning systems use a 3D representation of the CT scan of the patient under study as it provides a more intuitive view of the human jaw. The presence of metallic objects in human jaws, such as amalgam or gold fillings, provokes several artifacts like streaking and beam hardening which makes the reconstruction process difficult. In order to reduce these artifacts, several methods have been proposed using the raw data, directly obtained from the tomographs, in different ways. However, in DICOM-based applications this information is not available, and thus the need of a new method that handles this task in the DICOM domain. The presented method performs a morphological filtering in the polar domain yielding output images less affected by artifacts (even in cases of multiple metallic objects) without causing significant smoothing of the anatomic structures, which allows a great improvement in the 3D reconstruction. The algorithm has been automated and compared to other image denoising methods with successful results. (C) 2010 Elsevier Ireland Ltd. All rights reserved. | es_ES |
dc.description.sponsorship | This work has been supported by the project MIRACLE (DPI2007-66782-C03-01-AR07) of Spanish Ministerio de Educacion y Ciencia. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Computer Methods and Programs in Biomedicine | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Dental CT | es_ES |
dc.subject | Artifact reduction | es_ES |
dc.subject | Polar morphology | es_ES |
dc.subject.classification | TEORIA DE LA SEÑAL Y COMUNICACIONES | es_ES |
dc.subject.classification | EXPRESION GRAFICA EN LA INGENIERIA | es_ES |
dc.title | Metal artifact reduction in dental CT images using polar mathematical morphology | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.cmpb.2010.11.009 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MEC//DPI2007-66782-C03-01/ES/DESARROLLO DE UN SISTEMA AVANZADO DE DISEÑO, SIMULACION Y FABRICACION FLEXIBLE DE PROTESIS DENTALES IMPLANTOSOPORTADAS/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Comunicaciones - Departament de Comunicacions | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto Interuniversitario de Investigación en Bioingeniería y Tecnología Orientada al Ser Humano - Institut Interuniversitari d'Investigació en Bioenginyeria i Tecnologia Orientada a l'Ésser Humà | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Gráfica - Departament d'Enginyeria Gràfica | es_ES |
dc.description.bibliographicCitation | Naranjo Ornedo, V.; Llorens Rodríguez, R.; Alcañiz Raya, ML.; López-Mir, F. (2011). Metal artifact reduction in dental CT images using polar mathematical morphology. Computer Methods and Programs in Biomedicine. 102(1):64-74. https://doi.org/10.1016/j.cmpb.2010.11.009 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.cmpb.2010.11.009 | es_ES |
dc.description.upvformatpinicio | 64 | es_ES |
dc.description.upvformatpfin | 74 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 102 | es_ES |
dc.description.issue | 1 | es_ES |
dc.relation.senia | 41397 | |
dc.contributor.funder | Ministerio de Educación y Ciencia | es_ES |