dc.description.abstract | A Love Wave (LW) immunosensor was developed for the detection of carbaryl pesticide. The experimental setup consisted on: a compact electronic characterization circuit based on phase and amplitude detection at constant frequency; an automated flow injection system; a thermal control unit; a custom-made flow-through cell; and Quartz /SiO2 LW sensors with a 40 μm wavelength and 120 MHz center frequency. The carbaryl detection was based on a competitive immunoassay format using LIB-CNH45 monoclonal antibody (MAb). Bovine Serum Albumin-CNH (BSA-CNH) carbaryl hapten-conjugate was covalently immobilized, via mercaptohexadecanoic acid self-assembled monolayer (SAM), onto the gold sensing area of the LW sensors. This immobilization allowed the reusability of the sensor for at least 70 assays without significant signal losses. The LW immunosensor showed a limit of detection (LOD) of 0.09 μg/L, a sensitivity of 0.31 μg/L and a linear working range of 0.14–1.63 μg/L. In comparison to other carbaryl immunosensors, the LW immunosensor achieved a high sensitivity and a low LOD. These features turn the LW immunosensor into a promising tool for applications that demand a high resolution, such as for the detection of pesticides in drinking water at European regulatory levels. | es_ES |
dc.description.sponsorship | The author also would like to acknowledge the Spanish Ministry of Economy and Competitiveness and the European Regional Development Fund (ERDF) for their financing support through the grant of the INNPACTO 2012 project (DETECTA IPT-2012-0154-300000), J.V. Garcia's Fellowship, AP2007-03745, of FPU (Formacion de Profesorado Universitario) program, M. I. Rocha-Gaso's PhD CONACyT Fellowship and AWSensors Inc. for its collaboration. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | MDPI | es_ES |
dc.relation.ispartof | Sensors | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Biosensor | es_ES |
dc.subject | Carbaryl pesticide detection | es_ES |
dc.subject | Immunosensor | es_ES |
dc.subject | Love Wave sensor | es_ES |
dc.subject | Surface Acoustic Wave (SAW) | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.title | Love Wave Immunosensor for the Detection of Carbaryl Pesticide | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.3390/s140916434 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//IPT-2012-0154-300000/ES/DEMOSTRADOR TECNOLÓGICO BASADO EN TRANSDUCTORES ACÚSTICOS PARA APLICACIONES DE PREVENCIÓN Y DIAGNÓSTICO EN SALUD (DETECTA)/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MEC//AP2007-03745/ES/AP2007-03745/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto Interuniversitario de Investigación en Bioingeniería y Tecnología Orientada al Ser Humano - Institut Interuniversitari d'Investigació en Bioenginyeria i Tecnologia Orientada a l'Ésser Humà | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica | es_ES |
dc.description.bibliographicCitation | Rocha-Gaso, M.; García Narbón, JV.; García, P.; March Iborra, MDC.; Jiménez Jiménez, Y.; Francis, L.; Montoya Baides, Á.... (2014). Love Wave Immunosensor for the Detection of Carbaryl Pesticide. Sensors. 14(9):16434-16453. https://doi.org/10.3390/s140916434 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.3390/s140916434 | es_ES |
dc.description.upvformatpinicio | 16434 | es_ES |
dc.description.upvformatpfin | 16453 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 14 | es_ES |
dc.description.issue | 9 | es_ES |
dc.relation.senia | 269153 | |
dc.identifier.pmid | 25192313 | en_EN |
dc.identifier.pmcid | PMC4208181 | en_EN |
dc.contributor.funder | Ministerio de Educación y Ciencia | es_ES |
dc.contributor.funder | AWSensors S.L. | es_ES |
dc.contributor.funder | Ministerio de Economía y Competitividad | es_ES |
dc.description.references | March, C., Manclús, J. J., Jiménez, Y., Arnau, A., & Montoya, A. (2009). A piezoelectric immunosensor for the determination of pesticide residues and metabolites in fruit juices. Talanta, 78(3), 827-833. doi:10.1016/j.talanta.2008.12.058 | es_ES |
dc.description.references | Janshoff, A., Galla, H.-J., & Steinem, C. (2000). Piezoelectric Mass-Sensing Devices as Biosensors—An Alternative to Optical Biosensors? Angewandte Chemie, 39(22), 4004-4032. doi:10.1002/1521-3773(20001117)39:22<4004::aid-anie4004>3.0.co;2-2 | es_ES |
dc.description.references | Rocha-Gaso, M.-I., March-Iborra, C., Montoya-Baides, Á., & Arnau-Vives, A. (2009). Surface Generated Acoustic Wave Biosensors for the Detection of Pathogens: A Review. Sensors, 9(7), 5740-5769. doi:10.3390/s90705740 | es_ES |
dc.description.references | Gronewold, T. M. A. (2007). Surface acoustic wave sensors in the bioanalytical field: Recent trends and challenges. Analytica Chimica Acta, 603(2), 119-128. doi:10.1016/j.aca.2007.09.056 | es_ES |
dc.description.references | Länge, K., Rapp, B. E., & Rapp, M. (2008). Surface acoustic wave biosensors: a review. Analytical and Bioanalytical Chemistry, 391(5), 1509-1519. doi:10.1007/s00216-008-1911-5 | es_ES |
dc.description.references | Arnau, A., Montagut, Y., García, J. V., & Jiménez, Y. (2009). A different point of view on the sensitivity of quartz crystal microbalance sensors. Measurement Science and Technology, 20(12), 124004. doi:10.1088/0957-0233/20/12/124004 | es_ES |
dc.description.references | Montagut, Y. J., García, J. V., Jiménez, Y., March, C., Montoya, A., & Arnau, A. (2011). Frequency-shift vs phase-shift characterization of in-liquid quartz crystal microbalance applications. Review of Scientific Instruments, 82(6), 064702. doi:10.1063/1.3598340 | es_ES |
dc.description.references | Abad, A., Primo, J., & Montoya, A. (1997). Development of an Enzyme-Linked Immunosorbent Assay to Carbaryl. 1. Antibody Production from Several Haptens and Characterization in Different Immunoassay Formats. Journal of Agricultural and Food Chemistry, 45(4), 1486-1494. doi:10.1021/jf9506904 | es_ES |
dc.description.references | Manclús, J. J., Abad, A., Lebedev, M. Y., Mojarrad, F., Micková, B., Mercader, J. V., … Montoya, A. (2004). Development of a Monoclonal Immunoassay Selective for Chlorinated Cyclodiene Insecticides. Journal of Agricultural and Food Chemistry, 52(10), 2776-2784. doi:10.1021/jf035382h | es_ES |
dc.description.references | Francis, L. A., Friedt, J.-M., Zhou, C., & Bertrand, P. (2006). In Situ Evaluation of Density, Viscosity, and Thickness of Adsorbed Soft Layers by Combined Surface Acoustic Wave and Surface Plasmon Resonance. Analytical Chemistry, 78(12), 4200-4209. doi:10.1021/ac051233h | es_ES |
dc.description.references | Mauriz, E., Calle, A., Abad, A., Montoya, A., Hildebrandt, A., Barceló, D., & Lechuga, L. M. (2006). Determination of carbaryl in natural water samples by a surface plasmon resonance flow-through immunosensor. Biosensors and Bioelectronics, 21(11), 2129-2136. doi:10.1016/j.bios.2005.10.013 | es_ES |
dc.description.references | Abad, A., & Montoya, A. (1997). Development of an Enzyme-Linked Immunosorbent Assay to Carbaryl. 2. Assay Optimization and Application to the Analysis of Water Samples. Journal of Agricultural and Food Chemistry, 45(4), 1495-1501. doi:10.1021/jf950691w | es_ES |
dc.description.references | Montagut, Y., García, J. V., Jiménez, Y., March, C., Montoya, Á., & Arnau, A. (2011). Validation of a Phase-Mass Characterization Concept and Interface for Acoustic Biosensors. Sensors, 11(5), 4702-4720. doi:10.3390/s110504702 | es_ES |