dc.description.abstract |
A direct chemiluminescent procedure for determination of hydroquinone based on the emergent flow methodology known as multicommutation or tandem-flow is presented for first time. The manifold was based on a set of three channels and three solenoid valves; and, the determination was performed at 60degreesC and at flow-rate of 7.5 ml min(-1). The complete cycle lasted 35 s, which resulted in a sample flow trough of 103 h(-1). The chemical process was the hydroquinone oxidation with the system sulphuric acid-potassium permanganate; and the light emission was clearly enhanced by the presence of quinine sulphate and benzalkonium chloride reaching a detection limit of 30 Rg l(-1). The dynamic interval was over the range 0.1-15.0 mgl(-1) and a large list of interferents were assayed; the chemical robustness was also tested. The method was applied to different type of samples: namely, pharmaceutical formulations, a photographic solution and irrigation and residual superficial waters. (C) 2004 Elsevier B.V. All rights reserved. |
es_ES |
dc.language |
Inglés |
es_ES |
dc.publisher |
Elsevier |
es_ES |
dc.relation.ispartof |
Talanta |
es_ES |
dc.rights |
Reserva de todos los derechos |
es_ES |
dc.subject |
Hydroquinone |
es_ES |
dc.subject |
Chemiluminescence |
es_ES |
dc.subject |
Tandem-flow |
es_ES |
dc.subject |
Pharmaceuticals |
es_ES |
dc.subject |
Environmental samples |
es_ES |
dc.subject.classification |
QUIMICA ANALITICA |
es_ES |
dc.title |
A tandem-flow assembly for the chemiluminometric determination of hydroquinone |
es_ES |
dc.type |
Artículo |
es_ES |
dc.identifier.doi |
10.1016/j.talanta.2004.03.031 |
|
dc.rights.accessRights |
Cerrado |
es_ES |
dc.contributor.affiliation |
Universitat Politècnica de València. Departamento de Química - Departament de Química |
es_ES |
dc.contributor.affiliation |
Universitat Politècnica de València. Instituto de Investigación para la Gestión Integral de Zonas Costeras - Institut d'Investigació per a la Gestió Integral de Zones Costaneres |
es_ES |
dc.description.bibliographicCitation |
Gómez-Taylor Corominas, B.; Catalá Icardo, M.; Lahuerta Zamora, L.; García Mateo, JV.; Martínez Calatayud, J. (2004). A tandem-flow assembly for the chemiluminometric determination of hydroquinone. Talanta. 64(3):618-625. doi:10.1016/j.talanta.2004.03.031 |
es_ES |
dc.description.accrualMethod |
S |
es_ES |
dc.relation.publisherversion |
http://dx.doi.org/10.1016/j.talanta.2004.03.031 |
es_ES |
dc.description.upvformatpinicio |
618 |
es_ES |
dc.description.upvformatpfin |
625 |
es_ES |
dc.type.version |
info:eu-repo/semantics/publishedVersion |
es_ES |
dc.description.volume |
64 |
es_ES |
dc.description.issue |
3 |
es_ES |
dc.relation.senia |
25854 |
|