Mostrar el registro sencillo del ítem
dc.contributor.author | Gómez-Taylor Corominas, B. | es_ES |
dc.contributor.author | Catalá Icardo, Mónica | es_ES |
dc.contributor.author | Lahuerta Zamora, L. | es_ES |
dc.contributor.author | García Mateo, J. V. | es_ES |
dc.contributor.author | Martínez Calatayud, J. | es_ES |
dc.date.accessioned | 2015-07-10T14:11:06Z | |
dc.date.available | 2015-07-10T14:11:06Z | |
dc.date.issued | 2004-10-20 | |
dc.identifier.issn | 0039-9140 | |
dc.identifier.uri | http://hdl.handle.net/10251/53003 | |
dc.description.abstract | A direct chemiluminescent procedure for determination of hydroquinone based on the emergent flow methodology known as multicommutation or tandem-flow is presented for first time. The manifold was based on a set of three channels and three solenoid valves; and, the determination was performed at 60degreesC and at flow-rate of 7.5 ml min(-1). The complete cycle lasted 35 s, which resulted in a sample flow trough of 103 h(-1). The chemical process was the hydroquinone oxidation with the system sulphuric acid-potassium permanganate; and the light emission was clearly enhanced by the presence of quinine sulphate and benzalkonium chloride reaching a detection limit of 30 Rg l(-1). The dynamic interval was over the range 0.1-15.0 mgl(-1) and a large list of interferents were assayed; the chemical robustness was also tested. The method was applied to different type of samples: namely, pharmaceutical formulations, a photographic solution and irrigation and residual superficial waters. (C) 2004 Elsevier B.V. All rights reserved. | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Talanta | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Hydroquinone | es_ES |
dc.subject | Chemiluminescence | es_ES |
dc.subject | Tandem-flow | es_ES |
dc.subject | Pharmaceuticals | es_ES |
dc.subject | Environmental samples | es_ES |
dc.subject.classification | QUIMICA ANALITICA | es_ES |
dc.title | A tandem-flow assembly for the chemiluminometric determination of hydroquinone | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.talanta.2004.03.031 | |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Química - Departament de Química | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Investigación para la Gestión Integral de Zonas Costeras - Institut d'Investigació per a la Gestió Integral de Zones Costaneres | es_ES |
dc.description.bibliographicCitation | Gómez-Taylor Corominas, B.; Catalá Icardo, M.; Lahuerta Zamora, L.; García Mateo, JV.; Martínez Calatayud, J. (2004). A tandem-flow assembly for the chemiluminometric determination of hydroquinone. Talanta. 64(3):618-625. doi:10.1016/j.talanta.2004.03.031 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.talanta.2004.03.031 | es_ES |
dc.description.upvformatpinicio | 618 | es_ES |
dc.description.upvformatpfin | 625 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 64 | es_ES |
dc.description.issue | 3 | es_ES |
dc.relation.senia | 25854 |