dc.description.abstract | [EN] A flow injection analysis (FIA) manifold for the determination of penicillamine in pharmaceutical preparations is proposed. The manifold includes a solid-phase reactor for the in situ production of the derivatizing reagent, Co(II) ion, which forms a coloured complex with penicillamine in an alkaline medium. The reactor is prepared by natural immobilization of cobalt carbonate on a polymer matrix, which endows it with a high mechanical and microbiological stability. The cobalt released by passage of a 5 x 10(-4) Mol l(-1) sulphuric acid stream at a flow-rate of 2.3 ml min(-1) is merged with a volume of 314 mu l of sample containing penicillamine in ammonium-ammonia buffer at pH 9.5 to measure the absorbance at 360 nm. Beer's law is obeyed over the penicillamine concentration range 5-60 mg l(-1). The limit of detection (LOD) of the method is 1 mg l(-1) and its throughput 70 samples h(-1). (c) 2005 Elsevier B.V. All rights reserved. | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Journal of Pharmaceutical and Biomedical Analysis | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Penicillamine | es_ES |
dc.subject | Flow injection analysis | es_ES |
dc.subject | FIA | es_ES |
dc.subject | Solid-phase reactor | es_ES |
dc.subject | Pharmaceuticals | es_ES |
dc.subject | Cobalt | es_ES |
dc.subject.classification | QUIMICA ANALITICA | es_ES |
dc.title | In situ generation of Co(II) by use of a solid-phase reactor in an FIA assembly for the spectrophotometric determination of penicillamine | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.jpba.2005.02.044 | |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Química - Departament de Química | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Investigación para la Gestión Integral de Zonas Costeras - Institut d'Investigació per a la Gestió Integral de Zones Costaneres | es_ES |
dc.description.bibliographicCitation | Gómez-Taylor Corominas, B.; Pferzschner, J.; Catalá Icardo, M.; Lahuerta Zamora, L.; Martínez Calatayud, J. (2005). In situ generation of Co(II) by use of a solid-phase reactor in an FIA assembly for the spectrophotometric determination of penicillamine. Journal of Pharmaceutical and Biomedical Analysis. 39(1-2):281-284. doi:10.1016/j.jpba.2005.02.044 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.jpba.2005.02.044 | es_ES |
dc.description.upvformatpinicio | 281 | es_ES |
dc.description.upvformatpfin | 284 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 39 | es_ES |
dc.description.issue | 1-2 | es_ES |
dc.relation.senia | 27489 | |
dc.identifier.eissn | 1873-264X |