Mostrar el registro sencillo del ítem
dc.contributor.author | Alves, A. Augusto | es_ES |
dc.contributor.author | Andrade Filho, L. M. | es_ES |
dc.contributor.author | Barbosa, A. F. | es_ES |
dc.contributor.author | Bediaga, I. | es_ES |
dc.contributor.author | Cernicchiaro, G. | es_ES |
dc.contributor.author | Guerrer, G. | es_ES |
dc.contributor.author | Lima, H. P. | es_ES |
dc.contributor.author | Machado, A. A. | es_ES |
dc.contributor.author | Magnin, J. | es_ES |
dc.contributor.author | Marujo, F. | es_ES |
dc.contributor.author | de Miranda, J. M. | es_ES |
dc.contributor.author | Reis, A. | es_ES |
dc.contributor.author | Santos, A. | es_ES |
dc.contributor.author | Toledo, A. | es_ES |
dc.contributor.author | Toledo Alarcón, José Francisco | |
dc.date.accessioned | 2015-09-10T18:09:38Z | |
dc.date.available | 2015-09-10T18:09:38Z | |
dc.date.issued | 2008-08 | |
dc.identifier.issn | 1748-0221 | |
dc.identifier.uri | http://hdl.handle.net/10251/54510 | |
dc.description.abstract | The LHCb experiment is dedicated to precision measurements of CP violation and rare decays of B hadrons at the Large Hadron Collider (LHC) at CERN (Geneva). The initial configuration and expected performance of the detector and associated systems, as established by test beam measurements and simulation studies, is described. | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | IOP Publishing: Hybrid Open Access | es_ES |
dc.relation.ispartof | Journal of Instrumentation | es_ES |
dc.rights | Reconocimiento (by) | es_ES |
dc.subject | Large detector systems for particle and astroparticle physics | es_ES |
dc.subject | Particle tracking detectors | es_ES |
dc.subject | Particle identification methods | es_ES |
dc.subject | Photon detectors for UV, visible and IR photons | es_ES |
dc.subject | Detector cooling and thermo-stabilization | es_ES |
dc.subject | Detector design and construction technologies and materials. | es_ES |
dc.subject | Gaseous detectors | es_ES |
dc.subject | Calorimeters | es_ES |
dc.subject | Cherenkov detectors | es_ES |
dc.subject | Detector alignment and calibration methods | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.title | The LHCb Detector at the LHC | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1088/1748-0221/3/08/S08005 | |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular | es_ES |
dc.description.bibliographicCitation | Alves, AA.; Andrade Filho, LM.; Barbosa, AF.; Bediaga, I.; Cernicchiaro, G.; Guerrer, G.; Lima, HP.... (2008). The LHCb Detector at the LHC. Journal of Instrumentation. 3(8):1-205. doi:10.1088/1748-0221/3/08/S08005 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1088/1748-0221/3/08/S08005 | es_ES |
dc.description.upvformatpinicio | 1 | es_ES |
dc.description.upvformatpfin | 205 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 3 | es_ES |
dc.description.issue | 8 | es_ES |
dc.relation.senia | 246000 | |
dc.description.references | Moreira, P., Toifl, T., Kluge, A., Cervelli, G., Faccio, F., Marchioro, A., & Christiansen, J. (s. f.). G-link and gigabit Ethernet compliant serializer for LHC data transmission. 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149). doi:10.1109/nssmic.2000.949860 | es_ES |
dc.description.references | Haefeli, G., Bay, A., Gong, A., Gong, H., Muecke, M., Neufeld, N., & Schneider, O. (2006). The LHCb DAQ interface board TELL1. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 560(2), 494-502. doi:10.1016/j.nima.2005.12.212 | es_ES |
dc.description.references | Benvenuti, C., Chiggiato, P., Costa Pinto, P., Escudeiro Santana, A., Hedley, T., Mongelluzzo, A., … Wevers, I. (2001). Vacuum properties of TiZrV non-evaporable getter films. Vacuum, 60(1-2), 57-65. doi:10.1016/s0042-207x(00)00246-3 | es_ES |
dc.description.references | Gröbner, O. (2001). Overview of the LHC vacuum system. Vacuum, 60(1-2), 25-34. doi:10.1016/s0042-207x(00)00240-2 | es_ES |
dc.description.references | Andre, J., Charra, P., Flegel, W., Giudici, P. A., Jamet, O., Lancon, P., … Rosset, C. (2002). Status of the LHCb magnet system. IEEE Transactions on Appiled Superconductivity, 12(1), 366-371. doi:10.1109/tasc.2002.1018421 | es_ES |
dc.description.references | Andre, J., Flegel, W., Giudici, P. A., Jamet, O., & Losasso, M. (2004). Status of the LHCb Dipole Magnet. IEEE Transactions on Appiled Superconductivity, 14(2), 509-513. doi:10.1109/tasc.2004.829705 | es_ES |
dc.description.references | Patel, M., Losasso, M., & Gys, T. (2005). Magnetic shielding studies of the LHCb rich photon detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 553(1-2), 114-119. doi:10.1016/j.nima.2005.08.043 | es_ES |
dc.description.references | Artuso, M., & Wang, J. (2001). Study of the spatial resolution achievable with the BTeV pixel sensors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 465(1), 115-119. doi:10.1016/s0168-9002(01)00367-9 | es_ES |
dc.description.references | Abt, I., Fox, H., Moshous, B., Richter, R. H., Riechmann, K., Rietz, M., … Wagner, W. (1998). Gluing silicon with silicone. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 411(1), 191-196. doi:10.1016/s0168-9002(98)00301-5 | es_ES |
dc.description.references | Haas, T. (2007). Aging phenomena in the LHCb outer tracker. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 581(1-2), 164-166. doi:10.1016/j.nima.2007.07.063 | es_ES |
dc.description.references | Bevensee, B., Newcomer, F. M., Van Berg, R., & Williams, H. H. (1996). An amplifier-shaper-discriminator with baseline restoration for the ATLAS transition radiation tracker. IEEE Transactions on Nuclear Science, 43(3), 1725-1731. doi:10.1109/23.507211 | es_ES |
dc.description.references | Metlica, F. C. D. (2008). Development of light-weight spherical mirrors for RICH detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 595(1), 197-199. doi:10.1016/j.nima.2008.07.026 | es_ES |
dc.description.references | Barnykov, M. Y., Buzykaev, A. R., Danilyuk, A. F., Ganzhur, S. F., Goldberg, I. I., Kolachev, G. M., … Tayursky, V. A. (1998). Development of aerogel Cherenkov counters with wavelength shifters and phototubes. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 419(2-3), 584-589. doi:10.1016/s0168-9002(98)00871-7 | es_ES |
dc.description.references | Bellunato, T., Calvi, M., Matteuzzi, C., Musy, M., Negri, P., Braem, A., … Jolly, S. (2004). Performance of aerogel as Cherenkov radiator. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 519(3), 493-507. doi:10.1016/j.nima.2003.09.062 | es_ES |
dc.description.references | Bellunato, T., Calvi, M., Coluzza, C., Longo, G., Matteuzzi, C., Musy, M., … Perego, D. . (2004). Study of ageing effects in aerogel. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 527(3), 319-328. doi:10.1016/j.nima.2004.03.197 | es_ES |
dc.description.references | Bellunato, T., Calvi, M., Da Silva Costa, C. F., Matteuzzi, C., Musy, M., & Perego, D. L. (2006). Refractive index inhomogeneity within an aerogel block. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 556(1), 140-145. doi:10.1016/j.nima.2005.10.070 | es_ES |
dc.description.references | Ullaland, O. (2005). Fluid systems for RICH detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 553(1-2), 107-113. doi:10.1016/j.nima.2005.08.033 | es_ES |
dc.description.references | Braem, A., David, C., & Joram, C. (2005). Metal multi-dielectric mirror coatings for Cherenkov detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 553(1-2), 182-186. doi:10.1016/j.nima.2005.08.074 | es_ES |
dc.description.references | Albrecht, E., van Apeldoorn, G., Augustinus, A., Baillon, P., Battaglia, M., Bloch, D., … van Vulpen, I. (1999). Operation, optimisation, and performance of the DELPHI RICH detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 433(1-2), 47-58. doi:10.1016/s0168-9002(99)00320-4 | es_ES |
dc.description.references | Albrecht, E., Baum, G., Birsa, R., Borotto, F., Bradamante, F., Braem, A., … Zanetti, A. M. (2003). The mirror system of COMPASS RICH-1. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 502(1), 236-240. doi:10.1016/s0168-9002(03)00280-8 | es_ES |
dc.description.references | Alemia, M., Campbell, M., Gys, T., Mikulec, B., Piedigrossi, D., Puertolas, D., … Wyllie, K. (2000). First operation of a hybrid photon detector prototype with electrostatic cross-focussing and integrated silicon pixel readout. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 449(1-2), 48-59. doi:10.1016/s0168-9002(99)01448-5 | es_ES |
dc.description.references | Wyllie, K., Aglieri Rinella, G., Campbell, M., Castro Carballo, M., Gys, T., Jolly, S., … Somerville, L. (2004). Silicon detectors and electronics for pixel hybrid photon detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 530(1-2), 82-86. doi:10.1016/j.nima.2004.05.052 | es_ES |
dc.description.references | Adinolfi, M. (2005). System test of a three-column LHCb RICH-2 prototype detector. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 553(1-2), 328-332. doi:10.1016/j.nima.2005.08.083 | es_ES |
dc.description.references | Sancho, A. (1996). Receiver ASIC for timing, trigger and control distribution in LHC experiments. IEEE Transactions on Nuclear Science, 43(3), 1773-1777. doi:10.1109/23.507220 | es_ES |
dc.description.references | Arnaboldi, C., Bellunato, T., Gys, T., Panzeri, E., Pessina, G., & Piedigrossi, D. (s. f.). The High Voltage Distribution System for the Hybrid Photodetector Arrays of Rich1 and Rich2 at LhCb. IEEE Nuclear Science Symposium Conference Record, 2005. doi:10.1109/nssmic.2005.1596283 | es_ES |
dc.description.references | Adinolfi, M., Aglieri Rinella, G., Albrecht, E., Ameri, M., Arnaboldi, C., Bellunato, T., … Wyllie, K. (2007). Performance of the LHCb RICH photodetectors in a charged particle beam. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 574(1), 39-49. doi:10.1016/j.nima.2007.01.100 | es_ES |
dc.description.references | Easo, S., Belyaev, I., Corti, G., Jones, C., Papanestis, A., Pokorski, W., … Robbe, P. (2005). Simulation of LHCb RICH detectors using GEANT4. IEEE Transactions on Nuclear Science, 52(5), 1665-1668. doi:10.1109/tns.2005.856766 | es_ES |
dc.description.references | Ajaltouni, Z., Bohner, G., Carloganu, C., Cornat, R., Crouau, M., Deschamps, O., … Vilasis-Cardona, X. (2003). Study of multianode photomultipliers for the electromagnetic calorimeter preshower read out of the lhcb experiment. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 504(1-3), 9-13. doi:10.1016/s0168-9002(03)00742-3 | es_ES |
dc.description.references | Aguiló, E., Ballabriga, R., Comerma, A., Garrido, L., Gascón, D., Graciani, R., … Reinmuth, G. (2005). Test of multi-anode photomultiplier tubes for the LHCb scintillator pad detector. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 538(1-3), 255-264. doi:10.1016/j.nima.2004.08.116 | es_ES |
dc.description.references | Graugés, E., Comerma, A., Garrido, L., Gascón, D., Garra, J., Graciani, R., … Reinmuth, G. (2007). Mass characterization of MaPMT tubes for the LHCb scintillator pad detector. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 572(1), 427-428. doi:10.1016/j.nima.2006.10.221 | es_ES |
dc.description.references | Aguiló, E., Ballabriga, R., Calvo, M., Garrido, L., Gascón, D., Graciani, R., … Xirgu, X. (2005). Backsplash testbeam results for the SPD subdetector of LHCb. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 546(3), 438-447. doi:10.1016/j.nima.2005.02.036 | es_ES |
dc.description.references | Tarkovsky, E. (1996). The HERA-B electromagnetic calorimeter. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 379(3), 515-517. doi:10.1016/0168-9002(96)00558-x | es_ES |
dc.description.references | David, G., Kistenev, E., Patwa, A., Stoll, S., White, S., Woody, C., … Soldatov, A. (1996). Performance of the PHENIX EM Calorimeter. IEEE Transactions on Nuclear Science, 43(3), 1491-1495. doi:10.1109/23.507090 | es_ES |
dc.description.references | Badier, J., Busson, P., Charlot, C., Dobrzynski, L., Tanaka, R., Bordalo, P., … Semenjuk, I. (1994). Shashlik calorimeter Beam-test results. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 348(1), 74-86. doi:10.1016/0168-9002(94)90844-3 | es_ES |
dc.description.references | Dzhelyadin, R. . (2002). The LHCb hadron calorimeter. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 494(1-3), 332-339. doi:10.1016/s0168-9002(02)01489-4 | es_ES |
dc.description.references | Luengo, S., Gascón, D., Comerma, A., Garrido, L., Riera, J., Tortella, S., & Vilasís, X. (2006). SPD very front end electronics. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 567(1), 310-314. doi:10.1016/j.nima.2006.05.112 | es_ES |
dc.description.references | Lanfranchi, G. (2004). Time resolution and aging properties of the MWPCs for the LHCb Muon System. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 535(1-2), 221-225. doi:10.1016/j.nima.2004.07.142 | es_ES |
dc.description.references | Dané, E., Penso, G., Pinci, D., & Sarti, A. (2007). Detailed study of the gain of the MWPCs for the LHCb muon system. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 572(2), 682-688. doi:10.1016/j.nima.2006.12.026 | es_ES |
dc.description.references | Anelli, M., Campana, P., Dane, E., Forti, C., Martellotti, G., Penso, G., … Sciubba, A. (2006). Quality tests of the LHCb muon chambers at the LNF production site. IEEE Transactions on Nuclear Science, 53(1), 330-335. doi:10.1109/tns.2006.869836 | es_ES |
dc.description.references | Barbosa, A. F., Dumps, R., Graulich, J. S., Kachtchouk, A., Filho, L. M. A., Polycarpo, E., … Souvorov, V. (2006). Production and quality control of MWPC for the LHCb muon system at CERN. IEEE Transactions on Nuclear Science, 53(1), 336-340. doi:10.1109/tns.2006.869837 | es_ES |
dc.description.references | Dane, E., Pinci, D., & Sarti, A. (2007). Results of the Quality Controls of the Four-Gap MWPCs Produced at LNF for LHCb. IEEE Transactions on Nuclear Science, 54(2), 354-361. doi:10.1109/tns.2007.892947 | es_ES |
dc.description.references | Ciambrone, P., Dané, E., Dumps, R., Dwuznik, M., Felici, G., Forti, C., … Shubin, V. (2005). Automated wire tension measurement system for LHCb muon chambers. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 545(1-2), 156-163. doi:10.1016/j.nima.2004.12.039 | es_ES |
dc.description.references | Agosteo, S., Altieri, S., Belli, G., Bonifas, A., Carabelli, V., Gatignon, L., … Wegner, M. (2000). A facility for the test of large-area muon chambers at high rates. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 452(1-2), 94-104. doi:10.1016/s0168-9002(00)00414-9 | es_ES |
dc.description.references | Souvorov, V., Schneider, T., Schmidt, B., Riegler, W., Kashchuk, A., & Hutchcroft, D. (2003). First results of an aging test of a full scale MWPC prototype for the LHCb muon system. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 515(1-2), 220-225. doi:10.1016/j.nima.2003.09.001 | es_ES |
dc.description.references | Sauli, F. (1997). GEM: A new concept for electron amplification in gas detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 386(2-3), 531-534. doi:10.1016/s0168-9002(96)01172-2 | es_ES |
dc.description.references | Bencivenni, G., de Simone, P., Murtas, F., Lerner, M. P., Bonivento, W., Cardini, A., … Raspino, D. (2003). Advances in triple-GEM detector operation for high-rate particle triggering. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 513(1-2), 264-268. doi:10.1016/j.nima.2003.08.044 | es_ES |
dc.description.references | Alfonsi, M., Bencivenni, G., de Simone, P., Murtas, F., Lener, M. P., Sciascia, B., … Saitta, B. (2004). Advances in fast multi-GEM-based detector operation for high-rate charged-particle triggering. IEEE Transactions on Nuclear Science, 51(5), 2135-2139. doi:10.1109/tns.2004.836054 | es_ES |
dc.description.references | Bressan, A., Labbé, J. ., Pagano, P., Ropelewski, L., & Sauli, F. (1999). Beam tests of the gas electron multiplier. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 425(1-2), 262-276. doi:10.1016/s0168-9002(98)01406-5 | es_ES |
dc.description.references | Alfonsi, M., Baccaro, S., Bencivenni, G., Bonivento, W., Cardini, A., de Simone, P., … Saitta, B. (2005). Studies of etching effects on triple-GEM detectors operated with CF/sub 4/-based gas mixtures. IEEE Transactions on Nuclear Science, 52(6), 2872-2878. doi:10.1109/tns.2005.855640 | es_ES |
dc.description.references | Alfonsi, M., Bencivenni, G., de Simone, P., Murtas, F., Poli Lener, M., Bonivento, W., … Baccaro, S. (2006). Aging measurements on triple-GEM detectors operated with CF4-based gas mixtures. Nuclear Physics B - Proceedings Supplements, 150, 159-163. doi:10.1016/j.nuclphysbps.2005.03.054 | es_ES |
dc.description.references | Moraes, D., Anghinolfi, F., Deval, P., Jarron, P., Riegler, W., Rivetti, A., & Schmidt, B. (s. f.). CARIOCA-0.25 μm CMOS fast binary front-end for sensor interface using a novel current-mode feedback technique. ISCAS 2001. The 2001 IEEE International Symposium on Circuits and Systems (Cat. No.01CH37196). doi:10.1109/iscas.2001.921867 | es_ES |
dc.description.references | Cadeddu, S., Deplano, C., & Lai, A. (2005). The DIALOG chip in the front-end electronics of the LHCb muon detector. IEEE Transactions on Nuclear Science, 52(6), 2726-2732. doi:10.1109/tns.2005.862862 | es_ES |
dc.description.references | Cadeddu, S., De Leo, V., Deplano, C., & Lai, A. (2004). DIALOG and SYNC: a VLSI chip set for timing of the LHCb muon detector. IEEE Transactions on Nuclear Science, 51(5), 1961-1967. doi:10.1109/tns.2004.835574 | es_ES |
dc.description.references | Bocci, V., Chiodi, G., Iacoangeli, F., Messi, F., Di Marco, S., Nobrega, R., … Rossi, A. (2007). The services boards system for the LHCb muon detector (equalization, timing and monitoring of the 120k front end channels in the LHCb muon detector). 2007 IEEE Nuclear Science Symposium Conference Record. doi:10.1109/nssmic.2007.4436575 | es_ES |
dc.description.references | Corradi, G., Murtas, F., & Tagnani, D. (2007). A novel High-Voltage System for a triple GEM detector. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 572(1), 96-97. doi:10.1016/j.nima.2006.10.166 | es_ES |
dc.description.references | Aslanides, E., Cachemiche, J.-P., Cogan, J., Dinkespiler, B., Favard, S., Duval, P.-Y., … Tsaregorodtsev, A. (2007). The Level-0 muon trigger for the LHCb experiment. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 579(3), 989-1004. doi:10.1016/j.nima.2007.06.022 | es_ES |
dc.description.references | Sjöstrand, T., Edén, P., Friberg, C., Lönnblad, L., Miu, G., Mrenna, S., & Norrbin, E. (2001). High-energy-physics event generation with Pythia 6.1. Computer Physics Communications, 135(2), 238-259. doi:10.1016/s0010-4655(00)00236-8 | es_ES |