dc.description.abstract The present manuscript deals with a simple and sensitive flow-injection method for the chemiluminescent determination of thiazides. The method is based on the on-line photodegradation and chemiluminescent determination of the resulting photo-fragments. The on-line photodegradation is performed in basic medium by using a photoreactor consisting of a 550 cm long x 0.8 mm ID piece of PTFE tubing helically coiled around an 8 W low-pressure mercury lamp. The determination of the photo-irradiated thiazides is performed by a chemiluminescent oxidative reaction with Ce(IV) in sulphuric acid medium. A heterogeneous group of thiazides (indapamide, metolazone, hydroflumethiazide, chlorthalidone and bendroflumethiazide) has been studied. Hydrochlorothiazide was selected as a test substance. The "on-line" photochemical reaction approach allows the sensitive chemiluminescent determination of thiazides which do not present native chemiluminescence in the absence of sensitizers such as Rhodamine 6G. Linear calibration graphs were typically over the range 0.5-12 mug ml(-1) (indapamide, metolazone, hydroflumethiazide and chlorthalidone); and over the range 0.5-5 mug ml(-1) (hydrochlorothiazide). Limits of detection ranged between 0.005 mug ml(-1) (hydrochlorothiazide) and 0.06 mug ml(-1) (bendroflumethiazide). The relative standard deviation for the test substance was 2.0% for 2 mug l(-1) of the drug (n = 11) and the throughput was 65 h(-1) in all cases. The assessment of the photodegradation step on the molecular structure of thiazides was established by recording UV and fluorimetric spectra. The viability of the on-line photoinduced fluorescent determination of hydroflumethiazide and bendroflumethiazide was confirmed. The method was also applied to the determination of hydrochlorothiazide in commercially available formulation. (C) 2004 Elsevier B.V. All rights reserved. es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Journal of Pharmaceutical and Biomedical Analysis es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Chemiluminescence es_ES
dc.subject Photochemical reaction es_ES
dc.subject Hydrochlorothiazide es_ES
dc.subject Thiazides es_ES
dc.subject Pharmaceuticals es_ES
dc.subject FIA es_ES
dc.subject.classification QUIMICA ANALITICA es_ES
dc.title FI-chemiluminometric study of thiazides by on-line photochemical reaction es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.jpba.2004.08.020
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Química - Departament de Química es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Investigación para la Gestión Integral de Zonas Costeras - Institut d'Investigació per a la Gestió Integral de Zones Costaneres es_ES
dc.description.bibliographicCitation Ciborowski, M.; Catalá Icardo, M.; García Mateo, J.; Martínez Calatayud, J. (2004). FI-chemiluminometric study of thiazides by on-line photochemical reaction. Journal of Pharmaceutical and Biomedical Analysis. 36(4):693-700. doi:10.1016/j.jpba.2004.08.020 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1016/j.jpba.2004.08.020 es_ES
dc.description.upvformatpinicio 693 es_ES
dc.description.upvformatpfin 700 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 36 es_ES
dc.description.issue 4 es_ES
dc.relation.senia 25858
dc.identifier.eissn 1873-264X


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem